Accuracy of field alignment in abdominal radiation therapy

被引:6
|
作者
Kortmann, RD
Hess, CF
Meisner, C
Schmidberger, H
Bamberg, M
机构
[1] UNIV TUBINGEN, DEPT RADIOTHERAPY, D-72076 TUBINGEN, GERMANY
[2] UNIV TUBINGEN, INST MED INFORMAT PROC, D-72076 TUBINGEN, GERMANY
关键词
radiation therapy; quality assurance; verification films; patient positioning; seminoma;
D O I
10.1016/0360-3016(96)00152-6
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To assess the accuracy of field alignment in a homogeneous group of patients undergoing radiotherapy of the abdomen (adjuvant treatment of the paraaortic region in Stage I testicular seminoma), To evaluate the predictive value of the first verification on field placement errors during subsequent treatment delivery, Methods acid Materials: In 45 patients, linear and rotational discrepancies were measured between simulation and first check and between 10 consecutive verification films, Results: For the total group of patients, the distribution of all deviations showed mean values between 2.3 mm and -2.7 mm with standard deviations of 3.9 mm to 4.7 mm for linear discrepancies, and -0.5 degrees to 0.3 degrees with standard deviations of 1.2 degrees to 2.1 degrees for rotational discrepancies, respectively. For ail patients, deviations for the transition from simulator to the treatment machine were similar to deviations during subsequent treatment delivery, with 95% of all absolute deviations < 10.0 mm and 4 degrees, respectively, When performing correlation analysis between deviations at first check and during treatment delivery, a correlation for lateral displacements and a borderline correlation for caudal displacements could be found, There was no correlation for cranial and rotational displacements, Conclusions: Although a trend of deviations for subsequent treatment delivery may be shown at first check, our analysis indicates that the first verification cannot reliably predict inaccuracies during treatment delivery, Random fluctuations of field displacements of up to 1.0 cm prevail, They must be considered when prescribing the safety margins of the planned target volume and determining cutoff points for corrective actions in abdominal radiation therapy.
引用
收藏
页码:779 / 783
页数:5
相关论文
共 50 条
  • [1] ACCURACY OF RADIATION-FIELD ALIGNMENT IN CLINICAL-PRACTICE
    RABINOWITZ, I
    BROOMBERG, J
    GOITEIN, M
    MCCARTHY, K
    LEONG, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (10): : 1857 - 1867
  • [2] RADIATION THERAPY TARGETING ACCURACY WHEN COMBINED WITH ALTERNATING ELECTRIC FIELD THERAPY
    Grimm, Jimm
    Moore, Joseph
    Hooker, Ted
    Grimm, Rachel
    Huang, Ellen
    Jackson, Juan
    Redmond, Kristin
    Kleinberg, Lawrence
    NEURO-ONCOLOGY, 2017, 19 : 223 - 223
  • [3] An anthropomorphic abdominal phantom for deformable image registration accuracy validation in adaptive radiation therapy
    Liao, Yuliang
    Wang, Linjing
    Xu, Xiangdong
    Chen, Haibin
    Chen, Jiawei
    Zhang, Guoqian
    Lei, Huaiyu
    Wang, Ruihao
    Zhang, Shuxu
    Gu, Xuejun
    Zhen, Xin
    Zhou, Linghong
    MEDICAL PHYSICS, 2017, 44 (06) : 2369 - 2378
  • [4] ACCURACY IN RADIATION-FIELD ALIGNMENT IN HEAD AND NECK-CANCER - A PROSPECTIVE-STUDY
    HUIZENGA, H
    LEVENDAG, PC
    DEPORRE, PMZR
    VISSER, AG
    RADIOTHERAPY AND ONCOLOGY, 1988, 11 (02) : 181 - 187
  • [5] Improvement of alignment accuracy for scaled exposure field
    Nakajima, S
    Tanigawa, M
    Ishihama, A
    Sakiyama, K
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XI, 1997, 3050 : 135 - 142
  • [6] ALIGNMENT OF ATOMS IN THE FIELD OF HEAT RADIATION
    KOTYUSOV, AN
    NEMTSOV, BE
    OPTIKA I SPEKTROSKOPIYA, 1990, 69 (01): : 12 - 16
  • [7] REPRODUCIBILITY OF FIELD ALIGNMENT IN RADIATION-THERAPY - A LARGE-SCALE CLINICAL-EXPERIENCE
    KIHLEN, B
    RUDEN, BI
    ACTA ONCOLOGICA, 1989, 28 (05) : 689 - 692
  • [8] MRI-Guided Soft Tissue Alignment Improved Dose Delivery Accuracy for Head And Neck Radiation Therapy
    Wang, D.
    Neylon, J.
    Santhanam, A.
    Yang, Y.
    Chin, R.
    Qi, X.
    MEDICAL PHYSICS, 2017, 44 (06) : 3213 - 3213
  • [9] Dosimetric Comparison of Tomotherapy and Traditional Two-field Plans for Whole Abdominal Radiation Therapy
    Vatner, R. E.
    Stook, K.
    Willard, M.
    Dowsett, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S379 - S380
  • [10] Method to improve field alignment registration accuracy in VLSI lithography
    Liu, Jianhai
    Wang, Bin
    Zhang, Xiaoping
    Li, Bing-Zong
    International Conference on Solid-State and Integrated Circuit Technology Proceedings, 1998, : 109 - 112