Bacteriorhodopsin for superficial X-ray sensing

被引:7
作者
Ahmadi, Morteza [1 ,2 ]
Osei, Ernest K. [3 ,4 ]
Yeow, John T. W. [1 ,2 ]
机构
[1] Univ Waterloo, Dept Syst Design Engn, Waterloo, ON N2L 3G1, Canada
[2] Univ Waterloo, Waterloo Inst Nanotechnol, Waterloo, ON N2L 3G1, Canada
[3] Univ Waterloo, Dept Phys & Astron, Waterloo, ON N2L 3G1, Canada
[4] Grand River Reg Canc Ctr, Dept Med Phys, Kitchener, ON N2G 1G3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
X-ray sensing; Real time radiation sensor; key photon beam; Superficial X-ray beam; Membrane protein; Bacteriorhodopsin; EFFECTIVE ATOMIC NUMBERS; IN-VIVO DOSIMETRY; PURPLE-MEMBRANE; INDUCED CONDUCTIVITY; ELECTRIC PROPERTIES; RADIOCHROMIC FILM; MOSFET DETECTORS; RADIATION SENSOR; ENERGY; RANGE;
D O I
10.1016/j.snb.2012.02.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Bacteriorhodopsin is a proton-pump protein in the cell membrane of Halobacterium salinarium. Unlike many other biomaterials, bacteriorhodopsin keeps most of its physical, chemical and electrical properties in the dry thin film form. This makes bacteriorhodopsin an excellent candidate for fabrication of electromechanical devices in the scale of micrometer and possibly nanometer. In this paper, we report on employing a film of dry oriented bacteriorhodopsin for sensing kilovoltage (kV) energy X-ray beam. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:177 / 183
页数:7
相关论文
共 49 条
[1]   Fabrication and characterization of a radiation sensor based on bacteriorhodopsin [J].
Ahmadi, Morteza ;
Yeow, John T. W. .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (05) :2171-2176
[2]   Dose measurements in space by the Hungarian Pille TLD system [J].
Apáthy, I ;
Deme, S ;
Fehér, I ;
Akatov, YA ;
Reitz, G ;
Arkhanguelski, VV .
RADIATION MEASUREMENTS, 2002, 35 (05) :381-391
[3]  
Bakarudin I., 1992, J BIOL PHYS, V18, P203
[4]   PHOTOPHYSICS AND MOLECULAR ELECTRONIC APPLICATIONS OF THE RHODOPSINS [J].
BIRGE, RR .
ANNUAL REVIEW OF PHYSICAL CHEMISTRY, 1990, 41 :683-733
[5]   Radiation induced currents in MRI RF coils: application to linac/MRI integration [J].
Burke, B. ;
Fallone, B. G. ;
Rathee, S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (03) :735-746
[6]   Radiochromic film for medical radiation dosimetry [J].
Butson, MJ ;
Yu, PKN ;
Cheung, T ;
Metcalfe, P .
MATERIALS SCIENCE & ENGINEERING R-REPORTS, 2003, 41 (3-5) :61-120
[7]   THE ROLE OF RETINAL IN THE THERMAL-STABILITY OF THE PURPLE MEMBRANE [J].
CLADERA, J ;
GALISTEO, ML ;
SABES, M ;
MATEO, PL ;
PADROS, E .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1992, 207 (02) :581-585
[8]  
Colussi V C, 2001, J Appl Clin Med Phys, V2, P210, DOI 10.1120/1.1397155
[9]  
Dennison JR, 2009, AIP CONF PROC, V1099, P203, DOI 10.1063/1.3120015
[10]   Application of commercial MOSFET detectors for in vivo dosimetry in the therapeutic x-ray range from 80 kV to 250 W [J].
Ehringfeld, C ;
Schmid, S ;
Poljanc, K ;
Kirisits, C ;
Aiginger, H ;
Georg, D .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (02) :289-303