Model based water management diagnosis in polymer electrolyte membrane fuel cell

被引:23
作者
Esmaili, Qadir [1 ]
Nimvari, Majid Eshagh [1 ]
Jouybari, Nima Fallah [2 ]
Chen, Yong-Song [3 ,4 ]
机构
[1] Amol Univ Special Modern Technol, Fac Engn, Amol, Iran
[2] Lulea Univ Technol, Div Fluid Mech, S-97187 Lulea, Sweden
[3] Natl Chung Cheng Univ, Adv Inst Mfg High Tech Innovat, 168 Univ Rd, Minhsiung Township 62102, Chiayi, Taiwan
[4] Natl Chung Cheng Univ, Dept Mech Engn, 168 Univ Rd, Minhsiung Township 62102, Chiayi, Taiwan
关键词
Polymer electrolyte membrane fuel cell; Water management; Diagnosis; Segmented model; PRESSURE-DROP; FLOW CHANNELS; 2-PHASE FLOW; GAS-FLOW; EXCHANGE; TRANSPORT; CATHODE; DEGRADATION; UNIFORMITY; HUMIDITY;
D O I
10.1016/j.ijhydene.2020.04.031
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Water management diagnosis in polymer electrolyte membrane fuel cell is of great importance. The water produced in the fuel cell affects its performance and lifetime through the current distribution and the two phase flow pattern in the channel. The aim of the present study is to modify a segmented model in order to investigate a model-based water management diagnosis at different operating conditions. Simulations are conducted in three current densities: low (0.2 A/cm(2)), medium (0.6 A/cm(2)) and high (1 A/cm(2)), four temperatures ranged from 40 to 70, two stoichiometries (2 and 3) and four inlet humidities 25%, 50%,75% and 100%). The results show that at fully saturation inlet condition, there is a uniform local current density for all three considered current densities. Also, two-phase pressure drop and output voltage have similar trends. Hence two phase pressure drop can be considered as a suitable criterion for water management diagnosis. At inlet humidities less than 50%, non-uniformity of local current density increases that leads to reduction of less than 50%, non-uniformity of local current density increases that leads to reduction of output voltage, especially at high current density. Generally, for non-saturated inlet condition, two phase pressure drop and output voltage may show different trends. Therefore, two-phase pressure drop can be used only as a criterion for the formation of water and not for water management diagnosis. (C) 2020 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:15618 / 15629
页数:12
相关论文
共 50 条
  • [31] Improving polymer electrolyte membrane fuel cell performance and preventing flooding by exciting gas flow
    Kim, Ji Yeon
    Mortazavi, Mehdi
    Jung, Sung Yong
    [J]. JOURNAL OF POWER SOURCES, 2024, 617
  • [32] Mathematical Model of Proton Exchange Membrane Fuel Cell with Consideration of Water Management
    Yin, K. -M.
    Hsuen, H. -K.
    [J]. FUEL CELLS, 2013, 13 (06) : 1213 - 1225
  • [33] Water management of proton exchange membrane fuel cell based on control of hydrogen pressure drop
    Song, Mancun
    Pei, Pucheng
    Zha, Hongshan
    Xu, Huachi
    [J]. JOURNAL OF POWER SOURCES, 2014, 267 : 655 - 663
  • [34] Transient response of a polymer electrolyte membrane fuel cell subjected to modulating cell voltage
    Noorani, Shamsuddin
    Shamim, Tariq
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2013, 37 (06) : 535 - 546
  • [35] Numerical simulation of water droplet dynamics in a right angle gas channel of a polymer electrolyte membrane fuel cell
    Jo, Jae Hyuk
    Kim, Woo Tae
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2015, 40 (26) : 8368 - 8383
  • [36] Numerical modeling of liquid water motion in a polymer electrolyte fuel cell
    Jiang, Fangming
    Wang, Chao-Yang
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (02) : 942 - 950
  • [37] The Change of Water Distribution in Porous Media of the Polymer Electrolyte Membrane Fuel Cell after Freeze/thaw Cycles
    Ko, D.
    Doh, S.
    Yu, D. I.
    Park, H. S.
    Kim, M. H.
    [J]. FUEL CELLS, 2018, 18 (04) : 413 - 421
  • [38] The influence of porous transport layer modifications on the water management in polymer electrolyte membrane fuel cells
    Alink, R.
    Haussmann, J.
    Markoetter, H.
    Schwager, M.
    Manke, I.
    Gerteisen, D.
    [J]. JOURNAL OF POWER SOURCES, 2013, 233 : 358 - 368
  • [39] Expert diagnosis of polymer electrolyte fuel cells
    Davies, B.
    Jackson, L.
    Dunnett, S.
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (16) : 11724 - 11734
  • [40] CATHODE CATALYST LAYER MODEL FOR POLYMER ELECTROLYTE MEMBRANE FUEL CELL
    Kamarajugadda, Sai
    Mazumder, Sandip
    [J]. INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 6, PTS A AND B, 2013, : 789 - 798