Dose evaluation of organs at risk (OAR) cervical cancer using dose volume histogram (DVH) on brachytherapy

被引:3
作者
Wibowo, R. Arif [1 ]
Haris, Bambang [2 ]
Islamiyah, Inganatul
机构
[1] Airlangga Univ, Fac Sci & Technol, Dept Phys, Campus C Mulyorejo, Surabaya, Indonesia
[2] Dr Soetomo Hosp, Dept Radiotherapy, Surabaya, Indonesia
来源
INTERNATIONAL CONFERENCE ON PHYSICAL INSTRUMENTATION AND ADVANCED MATERIALS | 2017年 / 853卷
关键词
INTRACAVITARY; RECOMMENDATIONS; PARAMETERS;
D O I
10.1088/1742-6596/853/1/012013
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Brachytherapy is one way to cure cervical cancer. It works by placing a radioactive source near the tumor. However, there are some healthy tissues or organs at risk (OAR) such as bladder and rectum which received radiation also. This study aims to evaluate the radiation dose of the bladder and rectum. There were 12 total radiation dose data of the bladder and rectum obtained from patients' brachytherapy. The dose of cervix for all patients was 6 Gy. Two-dimensional calculation of the radiation dose was based on the International Commission on Radiation Units and Measurements (ICRU) points or called DICRU while the 3-dimensional calculation derived from Dose Volume Histogram (DVH) on a volume of 2 cc (D-2cc). The radiation dose of bladder and rectum from both methods were analysed using independent t test. The mean DICRU of bladder was 4.33730 Gy and its D2cc was4.78090 Gy. DICRU and D2cc bladder did not differ significantly (p = 0.144). The mean DICRU of rectum was 3.57980 Gy and 4.58670 Gy for D2cc. The mean DICRU of rectum differed significantly from D2cc of rectum (p = 0.000). The three-dimensional method radiation dose of the bladder and rectum was higher than the two-dimensional method with ratios 1.10227 for bladder and 1.28127 for rectum. The radiation dose of the bladder and rectum was still below the tolerance dose. Two-dimensional calculation of the bladder and rectum dose was lower than three-dimension which was more accurate due to its calculation at the whole volume of the organs.
引用
收藏
页数:6
相关论文
共 50 条
[21]   From point A to the sculpted pear: MR image guidance significantly improves tumour dose and sparing of organs at risk in brachytherapy of cervical cancer [J].
Tanderup, Kari ;
Nielsen, Soren Kynde ;
Nyvang, Gitte-Bettina ;
Pedersen, Erik Morre ;
Rohl, Lisbeth ;
Aagaard, Torben ;
Fokdal, Lars ;
Lindegaard, Jacob Christian .
RADIOTHERAPY AND ONCOLOGY, 2010, 94 (02) :173-180
[22]   PARAMETRIAL BOOST USING MIDLINE SHIELDING RESULTS IN AN UNPREDICTABLE DOSE TO TUMOR AND ORGANS AT RISK IN COMBINED EXTERNAL BEAM RADIOTHERAPY AND BRACHYTHERAPY FOR LOCALLY ADVANCED CERVICAL CANCER [J].
Fenkell, Louis ;
Assenholt, Marianne ;
Nielsen, Soren Kynde ;
Haie-Meder, Christine ;
Poetter, Richard ;
Lindegaard, Jacob ;
Tanderup, Kari .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (05) :1572-1579
[23]   Combined Interstitial and Intracavitary High-Dose Rate Brachytherapy of Cervical Cancer [J].
Itami, Jun ;
Murakami, Naoya ;
Watanabe, Miho ;
Sekii, Shuhei ;
Kasamatsu, Takahiro ;
Kato, Shingo ;
Hirowatari, Hisako ;
Ikushima, Hitoshi ;
Ando, Ken ;
Ohno, Tatsuya ;
Okamoto, Hiroyuki ;
Okuma, Kae ;
Igaki, Hiroshi .
FRONTIERS IN ONCOLOGY, 2022, 11
[24]   Validation of deformable dose accumulation for cervical cancer interstitial brachytherapy [J].
Wang, Binbing ;
Xu, Xiaoxian .
2018 NINTH INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY IN MEDICINE AND EDUCATION (ITME 2018), 2018, :323-326
[25]   Sigmoid dose using 3D imaging in cervical-cancer brachytherapy [J].
Holloway, Caroline L. ;
Racine, Marie-Lynn ;
Cormack, Robert A. ;
O'Farrell, Desmond A. ;
Viswanathan, Akila N. .
RADIOTHERAPY AND ONCOLOGY, 2009, 93 (02) :307-310
[26]   Experience in multicatheter interstitial high-dose-rate breast brachytherapy: dose-volume histogram analysis of the first results [J].
Demianovich, Alena ;
Sanin, Dmitriy ;
Martynova, Valeriya ;
Borysheva, Natalia ;
Obuhov, Aleksandr ;
Aminov, Gamzat ;
Gulidov, Igor ;
Mardyntsky, Yuriy ;
Kiseleva, Marina ;
Ivanov, Sergey ;
Kaprin, Andrey .
JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2019, 11 (04) :349-355
[27]   Effect of bladder distension on dosimetry of organs at risk in computer tomography based planning of high-dose-rate intracavitary brachytherapy for cervical cancer [J].
Patra, Niladri B. ;
Manir, Kazi S. ;
Basu, Swapnendu ;
Goswami, Jyotirup ;
Kabasi, Apurba K. ;
Sarkar, Shyamal K. .
JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2013, 5 (01) :3-9
[28]   Dose to the non-involved uterine corpus with MRI guided brachytherapy in locally advanced cervical cancer [J].
Sapru, Shantanu ;
Mohamed, Sandy ;
Fokdal, Lars ;
Nkiwane, Karen ;
Swamidas, Jamema ;
Mahantshetty, Umesh ;
Kirisits, Christian ;
Poetter, Richard ;
Lindegaard, Jacob Christian ;
Tanderup, Kari .
RADIOTHERAPY AND ONCOLOGY, 2013, 107 (01) :93-98
[29]   Dose Delivered to the Lumbosacral Plexus From High-Dose-Rate Brachytherapy for Cervical Cancer [J].
Rash, Dominique ;
Durbin-Johnson, Blythe ;
Lim, Jihoon ;
Dieterich, Sonja ;
Huddleston, Adam ;
Yi, Sun ;
Mayadev, Jyoti .
INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2015, 25 (05) :897-902
[30]   Robust Optimization of Dose-Volume Metrics for Prostate HDR-Brachytherapy Incorporating Target and OAR Volume Delineation Uncertainties [J].
Balvert, Marleen ;
den Hertog, Dick ;
Hoffmann, Aswin L. .
INFORMS JOURNAL ON COMPUTING, 2019, 31 (01) :100-114