The "independent breath" algorithm: assessment of oxygen uptake during exercise

被引:10
作者
Francescato, Maria Pia [1 ]
Cettolo, Valentina [1 ]
机构
[1] Univ Udine, Dept Med, Ple Kolbe 4, I-33100 Udine, Italy
关键词
Gas exchange; Signal-to-noise ratio; Mean response time; ALVEOLAR GAS-EXCHANGE; O-2; VENTILATION; VALUES; VO2;
D O I
10.1007/s00421-018-4046-1
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Purpose Reduction of noise of breath-by-breath gas-exchange data is crucial to improve measurements. A recently described algorithm (" independent breath"), that neglects the contiguity in time of breaths, was tested. Methods Oxygen, carbon dioxide fractions, and ventilatory flow were recorded continuously over 26 min in 20 healthy volunteers at rest, during unloaded and moderate intensity cycling and subsequent recovery; oxygen uptake (.V O 2) was calculated with the " independent breath" algorithm (IND) and, for comparison, with three other " classical" algorithms. Average.V O 2 and standard deviations were calculated for steady-state conditions; non-linear regression was run throughout the.V O 2 data of the transient phases (ON and OFF), using a mono-exponential function. Results Comparisons of the different algorithms showed that they yielded similar average.V O 2 at steady state (p = NS). The standard deviations were significantly lower for IND (post hoc contrasts, p < 0.001), with the slope of the relationship with the corresponding data obtained from " classical" algorithms being < 0.69. For both transients, the overall kinetics (evaluated as time delay + time constant) was significantly faster for IND (post hoc contrasts, p < 0.001). For the ON transient, the asymptotic standard errors of the kinetic parameters were significantly lower for IND, with the slope of the regression line with the corresponding values obtained from the " classical" algorithms being < 0.60. Conclusion The " independent breath" algorithm provided consistent average -O2 uptake values while reducing the overall noise of about 30%, which might result in the halving of the required number of repeated trials needed to assess the kinetic parameters of the ON transient.
引用
收藏
页码:495 / 508
页数:14
相关论文
共 30 条
[1]   EFFECT OF VENTILATION ON OXYGEN TRANSFER DURING EARLY EXERCISE [J].
AUCHINCLOSS, JH ;
GILBERT, R ;
BAULE, GH .
JOURNAL OF APPLIED PHYSIOLOGY, 1966, 21 (03) :810-+
[2]  
Bates D. M., 1988, Nonlinear regression analysis and its applications, V2, DOI DOI 10.1002/9780470316757
[3]   BREATH-BY-BREATH MEASUREMENT OF TRUE ALVEOLAR GAS-EXCHANGE [J].
BEAVER, WL ;
LAMARRA, N ;
WASSERMAN, K .
JOURNAL OF APPLIED PHYSIOLOGY, 1981, 51 (06) :1662-1675
[4]   Data collection, handling, and fitting strategies to optimize accuracy and precision of oxygen uptake kinetics estimation from breath-by-breath measurements [J].
Benson, Alan P. ;
Bowen, T. Scott ;
Ferguson, Carrie ;
Murgatroyd, Scott R. ;
Rossiter, Harry B. .
JOURNAL OF APPLIED PHYSIOLOGY, 2017, 123 (01) :227-242
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]   Evaluation of estimates of alveolar gas exchange by using a tidally ventilated nonhomogenous lung model [J].
Busso, T ;
Robbins, PA .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 82 (06) :1963-1971
[7]   New perspectives in breath-by-breath determination of alveolar gas exchange in humans [J].
Capelli, C ;
Cautero, M ;
di Prampero, PE .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 2001, 441 (04) :566-577
[8]   New acquisitions in the assessment of breath-by-breath alveolar gas transfer in humans [J].
Cautero, M ;
di Prampero, PE ;
Capelli, C .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2003, 90 (3-4) :231-241
[9]   Breath-by-breath alveolar oxygen transfer at the onset of step exercise in humans: methodological implications [J].
Cautero, M ;
Beltrami, AP ;
di Prampero, PE ;
Capelli, C .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2002, 88 (03) :203-213
[10]   Assessment of breath-by-breath alveolar gas exchange: an alternative view of the respiratory cycle [J].
Cettolo, V. ;
Francescato, Maria Pia .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2015, 115 (09) :1897-1904