Effect of planar microelectrode geometry on neuron stimulation: Finite element modeling and experimental validation of the efficient electrode shape

被引:15
|
作者
Ghazavi, Atefeh [1 ]
Westwick, David [1 ]
Xu, Fenglian [2 ]
Wijdenes, Pierre [2 ]
Syed, Naweed [2 ]
Dalton, Colin [1 ]
机构
[1] Univ Calgary, Dept Elect & Comp Engn, Calgary, AB T2N 1N4, Canada
[2] Univ Calgary, Hotchkiss Brain Inst, Dept Anat & Cell Biol, Calgary, AB T2N 4N1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Finite element model; Neuron stimulation; Neuron-electrode interface; Neuro-electronics; Lymnaea neurons; Electrode geometry; DEEP BRAIN-STIMULATION; NA+-CHANNELS; ARRAYS; CELLS;
D O I
10.1016/j.jneumeth.2015.03.024
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Microelectrode arrays have been used successfully for neuronal stimulation both in vivo and in vitro. However, in most instances currents required to activate the neurons have been in unphysiological ranges resulting in neuronal damage and cell death. There is a need to develop electrodes which require less stimulation current for neuronal activation with physiologically relevant efficacy and frequencies. New method: The objective of the present study was to examine and compare the stimulation efficiency of different electrode geometries at the resolution of a single neuron. We hypothesized that increasing the electrode perimeter will increase the maximum current density at the edges and enhance stimulation efficiency. To test this postulate, the neuronal stimulation efficacy of common circular electrodes (smallest perimeter) was compared with star (medium perimeter), and spiral (largest perimeter with internal boundaries) electrodes. We explored and compared using both a finite element model and in vitro stimulation of neurons isolated from Lymnaea central ganglia. Results: Interestingly, both the computational model and the live neuronal stimulation experiments demonstrated that the common circular microelectrode requires less stimulus to activate a cell compared to the other two electrode shapes with the same surface area. Our data further revealed that circular electrodes exhibit the largest sealing resistance, stimulus transfer, and average current density among the three types of electrodes tested. Comparison with existing methods: Average current density and not the maximum current density at the edges plays an important role in determining the electrode stimulation efficiency. Conclusion: Circular shaped electrodes are more efficient in inducing a change in neuronal membrane potential. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 50 条
  • [21] Experimental validation of finite element modeling for laser powder bed fusion deformation
    Dunbar, Alexander J.
    Denlinger, Erik R.
    Gouge, Michael F.
    Michaleris, Pan
    ADDITIVE MANUFACTURING, 2016, 12 : 108 - 120
  • [22] FINITE ELEMENT MODELING OF THE ULTRASOUND STIMULATED THERMOGRAPHY FOR VISCOELASTIC MATERIALS AND EXPERIMENTAL VALIDATION
    Hosten, Bernard
    Bacon, Christophe
    Biateau, Christine
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 28A AND 28B, 2009, 1096 : 503 - 510
  • [23] Power losses in magnetic laminations with hysteresis: Finite element modeling and experimental validation
    Basso, V
    Bertotti, G
    Bottauscio, O
    Fiorillo, F
    Pasquale, M
    Chiampi, M
    Repetto, M
    JOURNAL OF APPLIED PHYSICS, 1997, 81 (08) : 5606 - 5608
  • [24] Finite element modeling of micro-milling: Numerical simulation and experimental validation
    Ucun, Irfan
    Aslantas, Kubilay
    Bedir, Fevzi
    MACHINING SCIENCE AND TECHNOLOGY, 2016, 20 (01) : 148 - 172
  • [25] Finite element modeling and in vivo analysis of electrode configurations for selective stimulation of pudendal afferent fibers
    Woock, John P.
    Yoo, Paul B.
    Grill, Warren M.
    BMC UROLOGY, 2010, 10
  • [26] Finite element modeling and in vivo analysis of electrode configurations for selective stimulation of pudendal afferent fibers
    John P Woock
    Paul B Yoo
    Warren M Grill
    BMC Urology, 10
  • [27] Experimental validation of a computationally efficient beam element for combined finite–discrete element modelling of structures in distress
    T. Bangash
    A. Munjiza
    Computational Mechanics, 2003, 30 : 366 - 373
  • [28] Three-dimensional electrode arrays for retinal prostheses: modeling, geometry optimization and experimental validation
    Djilas, M.
    Oles, C.
    Lorach, H.
    Bendali, A.
    Degardin, J.
    Dubus, E.
    Lissorgues-Bazin, G.
    Rousseau, L.
    Benosman, R.
    Ieng, S-H
    Joucla, S.
    Yvert, B.
    Bergonzo, P.
    Sahel, J.
    Picaud, S.
    JOURNAL OF NEURAL ENGINEERING, 2011, 8 (04)
  • [29] Finite element modeling and experimental verification of lower extremity shape change under load
    Commean, PK
    Smith, KE
    Vannier, MW
    Szabo, BA
    Actis, RL
    JOURNAL OF BIOMECHANICS, 1997, 30 (05) : 531 - 536
  • [30] Finite Element Model to Study Effect of Source Geometry on Calcium Distribution in Cylindrical Shaped Neuron Cell
    Jha, Amrita
    Adlakha, Neeru
    2013 4TH NIRMA UNIVERSITY INTERNATIONAL CONFERENCE ON ENGINEERING (NUICONE 2013), 2013,