Effect of planar microelectrode geometry on neuron stimulation: Finite element modeling and experimental validation of the efficient electrode shape

被引:15
|
作者
Ghazavi, Atefeh [1 ]
Westwick, David [1 ]
Xu, Fenglian [2 ]
Wijdenes, Pierre [2 ]
Syed, Naweed [2 ]
Dalton, Colin [1 ]
机构
[1] Univ Calgary, Dept Elect & Comp Engn, Calgary, AB T2N 1N4, Canada
[2] Univ Calgary, Hotchkiss Brain Inst, Dept Anat & Cell Biol, Calgary, AB T2N 4N1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Finite element model; Neuron stimulation; Neuron-electrode interface; Neuro-electronics; Lymnaea neurons; Electrode geometry; DEEP BRAIN-STIMULATION; NA+-CHANNELS; ARRAYS; CELLS;
D O I
10.1016/j.jneumeth.2015.03.024
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Microelectrode arrays have been used successfully for neuronal stimulation both in vivo and in vitro. However, in most instances currents required to activate the neurons have been in unphysiological ranges resulting in neuronal damage and cell death. There is a need to develop electrodes which require less stimulation current for neuronal activation with physiologically relevant efficacy and frequencies. New method: The objective of the present study was to examine and compare the stimulation efficiency of different electrode geometries at the resolution of a single neuron. We hypothesized that increasing the electrode perimeter will increase the maximum current density at the edges and enhance stimulation efficiency. To test this postulate, the neuronal stimulation efficacy of common circular electrodes (smallest perimeter) was compared with star (medium perimeter), and spiral (largest perimeter with internal boundaries) electrodes. We explored and compared using both a finite element model and in vitro stimulation of neurons isolated from Lymnaea central ganglia. Results: Interestingly, both the computational model and the live neuronal stimulation experiments demonstrated that the common circular microelectrode requires less stimulus to activate a cell compared to the other two electrode shapes with the same surface area. Our data further revealed that circular electrodes exhibit the largest sealing resistance, stimulus transfer, and average current density among the three types of electrodes tested. Comparison with existing methods: Average current density and not the maximum current density at the edges plays an important role in determining the electrode stimulation efficiency. Conclusion: Circular shaped electrodes are more efficient in inducing a change in neuronal membrane potential. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 50 条
  • [1] Geometry-based finite-element modeling of the electrical contact between a cultured neuron and a microelectrode
    Buitenweg, J
    Rutten, WLC
    Marani, E
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (04) : 501 - 509
  • [2] Finite element modeling of the neuron-electrode interface
    Buitenweg, JR
    Rutten, WLC
    Marani, E
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2000, 19 (06): : 46 - 52
  • [3] Experimental validation of finite element modeling
    Vogel, D
    Jian, C
    De Wolf, I
    BENEFITING FROM THERMAL AND MECHANICAL SIMULATION IN MICRO-ELECTRONICS, 2000, : 113 - 133
  • [4] Multiphysics Finite-Element Modeling of the Neuron/Electrode Electrodiffusive Interaction
    Leva, Federico
    Verardo, Claudio
    Mele, Leandro Julian
    Palestri, Pierpaolo
    Selmi, Luca
    2022 IEEE SENSORS, 2022,
  • [5] 3-D finite element modeling analysis of epiretinal electrical stimulation - Effects of electrode size and electrode shape
    20144900289541
    (1) School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China, Future University Hakodate; IEEE Sapporo Section; Xiamen University (Institute of Electrical and Electronics Engineers Inc., United States):
  • [6] 3-D Finite Element Modeling Analysis of Epiretinal Electrical Stimulation -Effects of Electrode Size and Electrode Shape
    Cao, Xun
    Lyu, Qing
    Sui, Xiaohong
    Chai, Xinyu
    2014 INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE, ELECTRONICS AND ELECTRICAL ENGINEERING (ISEEE), VOLS 1-3, 2014, : 384 - 388
  • [7] Bone geometry on the contact stress in the shoulder for evaluation of pressure ulcers: Finite element modeling and experimental validation
    Luo, Ying
    Wang, Yancheng
    Tai, Bruce L.
    Chen, Roland K.
    Shih, Albert J.
    MEDICAL ENGINEERING & PHYSICS, 2015, 37 (02) : 187 - 194
  • [8] Ionic Buoyancy Engines: Finite Element Modeling and Experimental Validation
    Akl, James
    Alladkani, Fadi
    Akle, Barbar
    ELECTROACTIVE POLYMER ACTUATORS AND DEVICES (EAPAD) XXI, 2019, 10966
  • [9] Sonothermography in composite materials: Finite Element modeling and experimental validation
    Hosten, Bernard
    Biateau, Christine
    Bacon, Christophe
    Pradere, Christophe
    Batsale, Jean-Christophe
    Meziane, Anissa
    NDT & E INTERNATIONAL, 2012, 51 : 120 - 126
  • [10] Finite element modeling and experimental validation of the sealing mechanism of the ConFlat® joint
    Lutkiewicz, P.
    Rathjen, Ch.
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2008, 26 (03): : 537 - 544