Green Gas for Grid as an Eco-Friendly Alternative Insulation Gas to SF6: A Review

被引:27
作者
Pan, Baofeng [1 ]
Wang, Guoming [2 ]
Shi, Huimin [1 ]
Shen, Jiahua [2 ]
Ji, Hong-Keun [3 ]
Kil, Gyung-Suk [4 ]
机构
[1] Zhejiang Ocean Univ, Sch Port & Transportat Engn, Zhoushan 316022, Peoples R China
[2] Hangzhou Guozhou Power Technol Co Ltd, Hangzhou 310015, Peoples R China
[3] Natl Forens Serv, Busan Inst, Forens Safety Sect, Yangsan 50612, South Korea
[4] Korea Maritime & Ocean Univ, Dept Elect & Elect Engn, Busan 49112, South Korea
来源
APPLIED SCIENCES-BASEL | 2020年 / 10卷 / 07期
关键词
green gas for grid (g3); eco-friendly insulation gas; SF6; alternative; gas-insulated power facilities; dielectric strength; global warming potential (GWP); SULFUR-HEXAFLUORIDE SF6; BREAKDOWN CHARACTERISTICS; ELECTRICAL INSULATION; PARTIAL DISCHARGE; CF3I GAS; CO2; GAS; MIXTURE; SUBSTITUTE; PERFORMANCE; SF6/N-2;
D O I
10.3390/app10072526
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This paper deals with a review of the state-of-the-art performance investigations of green gas for grid (g3) gas, which is an emerging eco-friendly alternative insulation gas for sulfur hexafluoride (SF6) that will be used in gas-insulated power facilities for reducing environmental concerns. The required physical and chemical properties of insulation gas for high-voltage applications are discussed, including dielectric strength, arc-quenching capability, heat dissipation, boiling point, vapor pressure, compatibility, and environmental and safety requirements. Current studies and results on AC, DC, and lightning impulse breakdown voltage, as well as the partial discharge of g3 gas, are provided, which indicate an equivalent dielectric strength of g3 gas with SF6 after a proper design change or an increase in gas pressure. The switching bus-transfer current test, temperature rise test, and liquefaction temperature calculation also verify the possibility of replacing SF6 with g3 gas. In addition, the use of g3 gas significantly reduces theabovementioned environmental concerns in terms of global warming potential and atmosphere lifetime. In recent years, g3 gas-insulated power facilities, including switchgear, transmission line, circuit breaker, and transformer, have been commercially available in the electric power industry.
引用
收藏
页数:13
相关论文
共 72 条
[1]  
3M Company, 2017, NOVECTM 4710 INS GAS
[2]   Design Improvement of a 245-kV SF6 Circuit Breaker With Double-Speed Mechanism Through Current Zero Analysis [J].
Ahmethodzic, Almir ;
Smeets, Rene Peter Paul ;
Kertesz, Viktor ;
Kapetanovic, Mirsad ;
Sokolija, Kemo .
IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) :2496-2503
[3]  
[Anonymous], 2008, Official Journal of the European Union, V353, P1
[4]  
[Anonymous], 23 INT C EL DISTR CI
[5]  
[Anonymous], 2017, 622711 IEC
[6]  
[Anonymous], 2006, AUSTRIA J SLEEP R S1, V15, P1
[7]  
[Anonymous], 1998, Kyoto Protocol, P1
[8]  
[Anonymous], 2018, The Paris Agreement
[9]  
[Anonymous], 2017, 62271100AMD2ED2 IEC
[10]   Experimental Investigation of the Breakdown Voltage of CO2, N2, and SF6 Gases, and CO2-SF6 and N2-SF6 Mixtures under Different Voltage Waveforms [J].
Beroual, Abderrahmane ;
Khaled, Usama ;
Coulibaly, Mamadou-Lamine .
ENERGIES, 2018, 11 (04)