Contrast-enhanced MR angiography of subclavian steal syndrome: Value of the 2D time-of-flight "localizer" sign

被引:7
作者
Sheehy, N
MacNally, S
Smith, CS
Boyle, G
Madhavan, P
Meaney, JFM
机构
[1] St James Hosp, Dept Diagnost Imaging, Dublin 8, Ireland
[2] St James Hosp, Dept Vasc Surg, Dublin 8, Ireland
关键词
D O I
10.2214/AJR.04.1130
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Our objective was to determine if direction of flow within the vertebral artery could be reliably determined by evaluation of flow-sensitive, low-resolution 2D time-off-light (TOF) localizer images taken before 3D contrast-enhanced MR angiography (3D CEMRA) sequences in patients with unsuspected subclavian steal syndrome. CONCLUSION. Vertebral artery patency on 3D CEMRA in cases in which the vessel is absent on the TOF localizer in association with ipsilateral subclavian artery stenosis indicates reversal of flow in the vertebral artery and confirms the subclavian steal phenomenon. The combination of anatomic imaging with 3D CEMRA with functional information provided by the low-resolution TOF localizer confirms the diagnosis of subclavian steal without additional imaging.
引用
收藏
页码:1069 / 1073
页数:5
相关论文
共 50 条
[31]   3D Contrast-enhanced MR angiography [J].
Zhang, HongLei ;
Maki, Jeffrey H. ;
Prince, Martin R. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (01) :13-25
[32]   Time-resolved, contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
RADIOLOGY, 1996, 201 :1085-1085
[33]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351
[34]   Comparative evaluation of 2D time-of-flight and 3D elliptic centric contrast-enhanced MR venography in patients with presumptive cerebral venous and sinus thrombosis [J].
Klingebiel, R. ;
Bauknecht, H. C. ;
Bohner, G. ;
Kirsch, R. ;
Berger, J. ;
Masuhr, F. .
EUROPEAN JOURNAL OF NEUROLOGY, 2007, 14 (02) :139-143
[35]   Head and neck paragangliomas: Value of contrast-enhanced 3D MR angiography [J].
Neves, F. ;
Huwart, L. ;
Jourdan, G. ;
Reizine, D. ;
Herman, P. ;
Vicaut, E. ;
Guichard, J. P. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (05) :883-889
[36]   Contrast-enhanced MR angiography in Leriche's syndrome. [J].
Link, J ;
Steffens, JC ;
Brossmann, J ;
Loose, R ;
Heller, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 169 (01) :22-26
[37]   IMPROVED TIME-OF-FLIGHT MR ANGIOGRAPHY OF THE BRAIN WITH MAGNETIZATION TRANSFER CONTRAST [J].
EDELMAN, RR ;
AHN, SS ;
CHIEN, D ;
WEI, L ;
GOLDMANN, A ;
MANTELLO, M ;
KRAMER, J ;
KLEEFIELD, J .
RADIOLOGY, 1992, 184 (02) :395-399
[38]   Detection of pulmonary embolism: Comparison of contrast-enhanced spiral CT and time-of-flight MR techniques [J].
Woodard, PK ;
Sostman, HD ;
MacFall, JR ;
DeLong, DM ;
McDonald, JW ;
Foo, TKF .
JOURNAL OF THORACIC IMAGING, 1995, 10 (01) :59-72
[39]   Diagnostic Performance of Combined Contrast-Enhanced Magnetic Resonance Angiography and Phase-Contrast Magnetic Resonance Imaging in Suspected Subclavian Steal Syndrome [J].
Tsao, Teng-Fu ;
Cheng, Kai-Lun ;
Shen, Chao-Yu ;
Wu, Ming-Chi ;
Huang, Hsin-Hui ;
Su, Chun-Hung ;
Chen, Fong-Lin ;
Tyan, Yeu-Sheng ;
Lin, Yung-Chang .
CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2016, 67 (02) :190-201
[40]   2D TIME-OF-FLIGHT MR ANGIOGRAPHY AND PHASE-VELOCITY MAPPING IN PATIENTS WITH FEMOROPOPLITEAL BYPASSES [J].
VOSSHENRICH, R ;
MUELLER, E ;
HAUSMANN, R ;
FISCHER, U ;
VETTELSCHOSS, M ;
GRABBE, E .
RADIOLOGY, 1992, 185 :133-133