Seismic behavior of RC columns internally confined by CFRP strips

被引:7
作者
Halim, Nur Hajarul Falahi Abdul [1 ]
Alih, Sophia C. [2 ]
Vafaei, Mohammadreza [1 ]
机构
[1] Univ Teknol Malaysia, Fac Engn, Sch Civil Engn, Skudai, Malaysia
[2] Univ Teknol Malaysia, Sch Civil Engn, Inst Noise & Vibrat, Skudai, Malaysia
关键词
CFRP; RC column; stirrup; transverse reinforcement; quasi-static cyclic load; BASALT FIBER ROPES; SHEAR-STRENGTH; CONCRETE COLUMNS; BOND BEHAVIOR; FRP; PERFORMANCE; BEAMS; FRAMES; BARS; GFRP;
D O I
10.12989/acc.2021.12.3.217
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
During past decades fiber-reinforced polymer (FRP) sheets have been externally bonded to structural elements to increase their axial, shear, or bending capacity. FRP bars also have been widely used to replace the steel reinforcements in columns subjected to a harsh environment. In this study, carbon fiber-reinforced polymer (CFRP) strips were used as the transverse reinforcement for concrete columns. Although FRP bars have already been used as the transverse reinforcement in concrete columns, the efficiency and feasibility of CFRP strips have not been investigated. CFRP strips are flexible; therefore, they can be easily shaped as spirals to confine the concrete core of columns. The efficiency of CFRP strips for the confinement of the concrete core was examined through a series of quasi-static cyclic tests on four full-scale columns that had similar size and longitudinal reinforcements. One of the columns was selected as the reference, and steel spirals transversally reinforced it. CFRP strips transversally reinforced the other three columns with different widths and spacing. The obtained results showed that the number of cracks in the CFRP-confined columns was less than the reference column. The length of cracks in the CFRP-confined columns was also relatively shorter. Besides, the CFRP-confined columns had a larger ultimate load, effective yield strength, and displacement ductility ratio compared with the reference column.
引用
收藏
页码:217 / 225
页数:9
相关论文
共 50 条
[21]   Seismic behavior of PVC-CFRP confined reinforced concrete columns: An experimental study [J].
Yu, Feng ;
Yin, Wanyun ;
Cheng, Anchun ;
Vu, Quang-Viet ;
Wang, Shilong ;
Kong, Zhengyi .
STRUCTURES, 2021, 32 :313-328
[22]   Behaviour of thermally shocked RC columns internally confined by auxetic steel wire mesh [J].
Al-Rousan, Rajai Z. ;
Alnemrawi, Bara'a R. .
PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2023, 177 (10) :864-877
[23]   Behavior of RC beams strengthened with inclined CFRP strips [J].
Tanarslan, H. M. .
JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2010, 29 (21) :3275-3286
[24]   Comparative Analysis of Existing RC Columns Jacketed with CFRP or FRCC [J].
Del Zoppo, Marta ;
Di Ludovico, Marco ;
Balsamo, Alberto ;
Prota, Andrea .
POLYMERS, 2018, 10 (04)
[25]   Review on Seismic Behavior of RC Columns [J].
Xie Yongping ;
Jia Lei ;
Sun Gang .
ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING, PTS 1-4, 2013, 353-356 :2092-+
[26]   Experimental Study of Seismic Behavior of High-Strength RC Columns Strengthened with CFRP Subjected to Cyclic Loading [J].
Wang, Jizhong ;
Yang, Junlong ;
Cheng, Lu .
JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (02)
[27]   Nonuniform CFRP Wrapping to Prevent Sudden Failure of FRP Confined Square RC Columns [J].
Mai, Anh Duc ;
Sheikh, M. Neaz ;
Yamakado, Kento ;
Hadi, Muhammad N. S. .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2020, 24 (06)
[28]   Seismic performance and design of concrete columns confined with CFRP grids [J].
Saatcioglu, M ;
Grira, M .
FRP COMPOSITES IN CIVIL ENGINEERING, VOLS I AND II, PROCEEDINGS, 2001, :1227-1234
[29]   Tensile Forces Behavior on Longitudinal Reinforcement and CFRP Strips on Circular Hollow Reinforced Concrete Columns [J].
Dewi, Sri Hartati ;
Thamrin, Rendy ;
Haris, Sabril ;
Yastari, Febi Putri .
CIVIL AND ENVIRONMENTAL ENGINEERING, 2024, 20 (01) :86-97
[30]   Design model for square RC columns under compression confined with CFRP [J].
Faustino, Pedro ;
Chastre, Carlos ;
Paula, Raquel .
COMPOSITES PART B-ENGINEERING, 2014, 57 :187-198