Development of a PET-Transrectal Ultrasound Prostate Imaging System

被引:5
|
作者
Huber, Jennifer S. [1 ]
Peng, Qiyu [1 ]
Moses, William W. [1 ]
Reutter, Bryan W. [1 ]
Pouliot, Jean [2 ]
Hsu, I. Chow [2 ]
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Lab, Berkeley, CA 94720 USA
[2] UCSF Comprehens Canc Ctr, Dept Radiat Oncol, San Francisco, CA 94143 USA
关键词
Cancer; image registration; positron emission tomography; ultrasound; POSITRON-EMISSION-TOMOGRAPHY; CANCER; F-18-FDG; VOLUME; 16-BETA-F-18-FLUORO-5-ALPHA-DIHYDROTESTOSTERONE; LOCALIZATION; EXPERIENCE; CHOLINE; ACID; CT;
D O I
10.1109/TNS.2011.2136387
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Multimodality imaging has an increasing role in the management of a large number of diseases, particularly if both functional and structural information are acquired and accurately registered. Transrectal ultrasound (TRUS) imaging is currently an integral part of prostate cancer diagnosis and treatment procedures, providing high-resolution anatomical detail of the prostate region. Positron Emission Tomography (PET) imaging with C-11-choline is a sensitive functional imaging technique that can identify biochemical states associated with prostate cancer. We believe that merging these prostate imaging technologies will help identify the location and aggressiveness of prostate cancer. We envision using dual PET-TRUS prostate imaging to guide biopsy, guide treatment procedures, and detect local recurrence earlier than is currently possible. Hence, we have developed a dual PET-TRUS prostate imaging system and protocol designed to allow accurate 3-D image registration. We have evaluated this PET-TRUS system by performing dual PET-TRUS imaging of custom phantoms. We describe here our dual-modality imaging system, custom phantoms and phantom study results. We also discuss our investigation of the PET-TRUS registration accuracy. We measure an average PET-TRUS registration error for our phantom studies of 2.1 +/- 1.7 mm in the x direction, 1.9 +/- 1.6 mm in the y direction, and 0.6 +/- 0.2 mm in the z direction. This registration accuracy is sufficient for some clinical applications such as biopsy guidance and early detection of recurrence.
引用
收藏
页码:674 / 681
页数:8
相关论文
共 50 条
  • [1] Simultaneous transrectal ultrasound and photoacoustic human prostate imaging
    Kothapalli, Sri-Rajasekhar
    Sonn, Geoffrey A.
    Choe, Jung Woo
    Nikoozadeh, Amin
    Bhuyan, Anshuman
    Park, Kwan Kyu
    Cristman, Paul
    Fan, Richard
    Moini, Azadeh
    Lee, Byung Chul
    Wu, Jonathan
    Carver, Thomas E.
    Trivedi, Dharati
    Shiiba, Lillian
    Steinberg, Idan
    Huland, David M.
    Rasmussen, Morten F.
    Liao, Joseph C.
    Brooks, James D.
    Khuri-Yakub, Pierre T.
    Gambhir, Sanjiv S.
    SCIENCE TRANSLATIONAL MEDICINE, 2019, 11 (507)
  • [2] Combined Ultrasound and Transrectal Electrical Impedance Imaging of the Prostate
    Wan, Y.
    Halter, R.
    Heaney, J.
    Seigne, J.
    Schned, A.
    Borsic, A.
    Hartov, A.
    2012 38TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC), 2012, : 181 - 182
  • [3] Characterisation of Prostate Lesions Using Transrectal Shear Wave Elastography (SWE) Ultrasound Imaging: A Systematic Review
    Anbarasan, Thineskrishna
    Wei, Cheng
    Bamber, Jeffrey C.
    Barr, Richard G.
    Nabi, Ghulam
    CANCERS, 2021, 13 (01) : 1 - 15
  • [4] Molecular Imaging of Prostate Cancer: PET Radiotracers
    Jadvar, Hossein
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (02) : 278 - 291
  • [5] Environmental Impact of Prostate Magnetic Resonance Imaging and Transrectal Ultrasound Guided Prostate Biopsy
    Leapman, Michael S.
    Thiel, Cassandra L.
    Gordon, Ilyssa O.
    Nolte, Adam C.
    Perecman, Aaron
    Loeb, Stacy
    Overcash, Michael
    Sherman, Jodi D.
    EUROPEAN UROLOGY, 2023, 83 (05) : 463 - 471
  • [6] Magnetic resonance imaging-transrectal ultrasound fusion focal cryotherapy of the prostate: A prospective development study
    Valerio, Massimo
    Shah, Taimur Tariq
    Shah, Paras
    Mccartan, Neil
    Emberton, Mark
    Arya, Manit
    Ahmed, Hashim Uddin
    UROLOGIC ONCOLOGY-SEMINARS AND ORIGINAL INVESTIGATIONS, 2017, 35 (04) : 150.e1 - 150.e7
  • [7] Technique for a hybrid system of real-time transrectal ultrasound with preoperative magnetic resonance imaging in the guidance of targeted prostate biopsy
    Ukimura, Osamu
    Hirahara, Naoki
    Fujihara, Atsuko
    Yamada, Takeshi
    Iwata, Tsuyoshi
    Kamoi, Kazumi
    Okihara, Koji
    Ito, Hirotoshi
    Nishimura, Tsunehiko
    Miki, Tsuneharu
    INTERNATIONAL JOURNAL OF UROLOGY, 2010, 17 (10) : 890 - 893
  • [8] Clinical practice in prostate PET imaging
    Huls, Sean J.
    Burkett, Brian
    Ehman, Eric
    Lowe, Val J.
    Subramaniam, Rathan M.
    Kendi, A. Tuba
    THERAPEUTIC ADVANCES IN MEDICAL ONCOLOGY, 2023, 15
  • [9] PROSTATE-SPECIFIC ANTIGEN AND TRANSRECTAL ULTRASOUND OF THE PROSTATE IN DETECTION OF PROSTATE-CANCER
    COONER, WH
    CLINICAL AND INVESTIGATIVE MEDICINE, 1993, 16 (06): : 471 - 474
  • [10] Design, Development, and Multi-Characterization of an Integrated Clinical Transrectal Ultrasound and Photoacoustic Device for Human Prostate Imaging
    Agrawal, Sumit
    Johnstonbaugh, Kerrick
    Clark, Joseph Y.
    Raman, Jay D.
    Wang, Xueding
    Kothapalli, Sri-Rajasekhar
    DIAGNOSTICS, 2020, 10 (08)