Wide-area monitoring and control using the real time digital simulator and a synchrophasor vector processor

被引:15
作者
Srivastava, Anurag [2 ]
Ravikumar, Krishnanjan Gubba [1 ]
Zweigle, Greg [1 ]
机构
[1] Schweitzer Engn Labs Inc, Pullman, WA USA
[2] Mississippi State Univ, Starkville, MS USA
来源
EUROPEAN TRANSACTIONS ON ELECTRICAL POWER | 2011年 / 21卷 / 04期
关键词
synchrophasors; real time digital simulator; transient stability; synchrophasor vector processor; wide-area control; system integrity protection scheme; FAULT DETECTION/LOCATION TECHNIQUE; TRANSMISSION-LINES; SYSTEM; PLACEMENT; STABILITY;
D O I
10.1002/etep.548
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Several major blackouts in the past have shown the need for advanced wide-area monitoring and control (WAMC) techniques. Advanced synchrophasor visualization and monitoring can be realized with time-referenced power system data that are collected by phasor measurement units (PMUs) using synchronized clocks. Presently, PMUs are being deployed around the world at a rapid rate for various power system applications. When a necessary number of PMUs are installed at optimal locations throughout the network, the complete state of the system can be observed. PMUs take real-time measurements to determine the state of the power system and can be used to enhance state estimation efficiency. With PMUs in place, there are many control and protection schemes that can be implemented successfully to take preventive and corrective actions. These remedial action schemes (RASs) are classified by the IEEE Power System Relaying Committee (PSRC) as system integrity protection schemes (SIPSs). This work involved the development of a real-time hardware test bed in order to analyze the transient stability of a simulated power system by using synchrophasors to visualize system stress across a transmission line with and without load-shedding schemes. The real time digital simulator (RTDS (R)) was used to model the power system in real time. PMUs, a satellite-synchronized clock, and a synchrophasor vector processor (SVP) were used to test the synchrophasor application. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:1521 / 1530
页数:10
相关论文
共 27 条
  • [1] [Anonymous], 2006, P 33 ANN W PROT REL
  • [2] [Anonymous], 1994, POWER SYSTEM STABILI
  • [3] Computation of time delay margin for power system small-signal stability
    Ayasun, Saffet
    [J]. EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2009, 19 (07): : 949 - 968
  • [4] Placement of PMUs to enable bad data detection in state estimation
    Chen, Jian
    Abur, Ali
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2006, 21 (04) : 1608 - 1615
  • [5] DAGLE J, 2009, P 42 HAW INT C SYST, DOI DOI 10.1109/HICSS.2009.325
  • [6] DAHAL N, 2009, P POW SYST C EXP SEA, DOI DOI 10.1109/PSCE.2009.4840207
  • [7] Glover J.D., 2008, POWER SYSTEM ANAL DE, Vfourth
  • [8] HUANG Q, 2009, IEEE POW EN SOC GEN, DOI DOI 10.1109/PES.2009.5275199
  • [9] Jiang JA, 2000, IEEE T POWER DELIVER, V15, P486
  • [10] PMU configuration for system dynamic performance measurement in large multiarea power systems
    Kamwa, I
    Grondin, R
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2002, 17 (02) : 385 - 394