Patient assessment using standardized bone mineral density values and a national reference database: implementing uniform thresholds for the reimbursement of osteoporosis treatments in Belgium

被引:26
作者
Boonen, S
Kaufman, JM
Reginster, JY
Devogelaer, JP
机构
[1] Katholieke Univ Leuven, Div Geriatr Med, Louvain, Belgium
[2] Leuven Univ, Ctr Metab Bone Dis, Louvain, Belgium
[3] Ghent Univ Hosp, Unit Osteoporosis & Metab Bone Dis, Ghent, Belgium
[4] State Univ Liege, Ctr Univ Invest Metab Osseux & Cartilage Articula, B-4000 Liege, Belgium
[5] Catholic Univ Louvain, Arthrit Unit, B-3000 Louvain, Belgium
关键词
D O I
10.1007/s00198-002-1321-z
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dual-energy X-ray absorptiometry (DXA) devices from the three main manufacturers provide different bone mineral density (BMD) values, due in part to technical differences in the algorithms for bone mineral content (BMC) and area measurements and in part to the use of different manufacturer-derived reference databases. As a result, significant differences exist between Hologic, Lunar and Norland systems in the reported young normal standard deviation scores or T-scores. In a number of European countries, including Belgium, a T-score below -2.5 is one of the key criteria for reimbursement of osteoporosis treatments. This paper addresses the first attempt to implement a nationwide, uniform expression of BMD in patients, in order to harmonize drug reimbursement. To this end, measures were taken to implement a uniform expression of BMD in Belgian patients, by converting each manufacturer's absolute BMD to standardized BMD (sBMD) values and by establishing a single national reference range.
引用
收藏
页码:110 / 115
页数:6
相关论文
共 22 条
[1]   Screening for osteopenia and osteoporosis: Do the accepted normal ranges lead to overdiagnosis? [J].
Ahmed, AIH ;
Blake, GM ;
Rymer, JM ;
Fogelman, I .
OSTEOPOROSIS INTERNATIONAL, 1997, 7 (05) :432-438
[2]  
[Anonymous], 1994, ASS FRACT RISK ITS A
[3]   A randomized trial of nasal spray salmon calcitonin in postmenopausal women with established osteoporosis: the prevent recurrence of osteoporotic fractures study [J].
Chesnut, CH ;
Silverman, S ;
Andriano, K ;
Genant, H ;
Gimona, A ;
Harris, S ;
Kiel, D ;
LeBoff, M ;
Maricic, M ;
Miller, P ;
Moniz, C ;
Peacock, M ;
Richardson, P ;
Watts, N ;
Baylink, D .
AMERICAN JOURNAL OF MEDICINE, 2000, 109 (04) :267-276
[4]   Effect of alendronate on risk of fracture in women with low bone density but without vertebral fractures - Results from the fracture intervention trial [J].
Cummings, SR ;
Black, DM ;
Thompson, DE ;
Applegate, WB ;
Barrett-Connor, E ;
Musliner, TA ;
Palermo, L ;
Prineas, R ;
Rubin, SM ;
Scott, JC ;
Vogt, T ;
Wallace, R ;
Yates, AJ ;
LaCroix, AZ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1998, 280 (24) :2077-2082
[5]  
EDDY DM, 1998, OSTEOPOROS INT S4, V8, pS1
[6]   Reduction of vertebral fracture risk in postmenopausal women with osteoporosis treated with raloxifene -: Results from a 3-year randomized clinical trial [J].
Ettinger, B ;
Black, DM ;
Mitlak, BH ;
Knickerbocker, RK ;
Nickelsen, T ;
Genant, HK ;
Christiansen, C ;
Delmas, PD ;
Zanchetta, JR ;
Stakkestad, J ;
Glüer, CC ;
Krueger, K ;
Cohen, FJ ;
Eckert, S ;
Ensrud, KE ;
Avioli, LV ;
Lips, P ;
Cummings, SR .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 282 (07) :637-645
[7]   Discrepancies in normative data between Lunar and Hologic DXA systems [J].
Faulkner, KG ;
Roberts, LA ;
McClung, MR .
OSTEOPOROSIS INTERNATIONAL, 1996, 6 (06) :432-436
[8]  
GENANT HK, 1994, J BONE MINER RES, V9, P1503
[9]   Inappropriate reference range for peak bone mineral density in dual-energy X-ray absorptiometry:: Implications for the interpretation of T-scores [J].
Gürlek, A ;
Bayraktar, M ;
Ariyürek, M .
OSTEOPOROSIS INTERNATIONAL, 2000, 11 (09) :809-813
[10]   Standardization of femur BMD [J].
Hanson, J .
JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 (08) :1316-1317