Kinetics of emitted mass-A study with three dry powder inhaler devices

被引:24
作者
Behara, Srinivas Ravindra Babu [1 ]
Kippax, Paul [2 ]
Larson, Ian [1 ]
Morton, David A. V. [1 ]
Stewart, Peter [1 ]
机构
[1] Monash Univ, Monash Inst Pharmaceut Sci, Parkville, Vic 3052, Australia
[2] Malvern Instruments, Malvern WR14 1XZ, Worcs, England
关键词
Aerosol concentration; Dry powder inhaler device; Emitted mass; Kinetics; Laser diffraction; Non-linear regression modelling; IN-VITRO; RESISTANCE; PERFORMANCE; CAPSULE; DRUG; FLOW;
D O I
10.1016/j.ces.2011.07.029
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The purpose of this study was to understand the kinetics of emptying of micronised salbutamol sulphate (SS) and lactohale 300 (LH300) under varying air flow rates (30-180 L mm(-1)) from three dry powder inhaler devices, Rotahaler (R) (RH), Monodose Inhaler (R) (MI) and Handihaler (R) (HH). Aerosol concentration vs. time profiles, determined through real-time laser diffraction particle sizing, demonstrated that the majority of the powder from RH was emitted within one second while a more prolonged aerosolisation was observed from MI and HH. Peak aerosol concentrations were achieved more rapidly from RH compared to MI for both SS and LH300. Calculated cumulative emitted mass (CCEM) vs. time profiles were obtained from the aerosol concentration vs. time profiles and the emitted mass and the rate of CCEM (k(CCEM)), estimated from a modelling approach, increased with increasing air flow rates. The k(CCEM) vs. air flow rate profiles of SS and LH300 were significantly different at high air flow rates. The k(CCEM) was highest from RH and lowest from MI. Differences in k(CCEM) between the devices were related to capsule aperture size while the differences between the materials were due to the powder bed structure. This approach provided an understanding of the rate at which powder mass emptied from dry powder inhaler devices and was proposed to be a powerful development tool for the future powder inhalers. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:5284 / 5292
页数:9
相关论文
共 16 条
[1]   Modelling the dissolution of diazepam in lactose interactive mixtures [J].
Alway, B ;
Sangchantra, R ;
Stewart, PJ .
INTERNATIONAL JOURNAL OF PHARMACEUTICS, 1996, 130 (02) :213-224
[2]  
[Anonymous], 1966, Applied regression analysis
[3]   An approach to characterising the cohesive behaviour of powders using a flow titration aerosolisation based methodology [J].
Behara, Srinivas Ravindra Babu ;
Larson, Ian ;
Kippax, Paul ;
Morton, David A. V. ;
Stewart, Peter .
CHEMICAL ENGINEERING SCIENCE, 2011, 66 (08) :1640-1648
[4]   Structural influence of cohesive mixtures of salbutamol sulphate and lactose on aerosolisation and de-agglomeration behaviour under dynamic conditions [J].
Behara, Srinivas Ravindra Babu ;
Kippax, Paul ;
McIntosh, Michelle P. ;
Morton, David A. V. ;
Larson, Ian ;
Stewart, Peter .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2011, 42 (03) :210-219
[5]   Characterization of pharmaceutical powder inhalers: estimation of energy input for powder dispersion and effect of capsule device configuration [J].
Chew, NYK ;
Chan, HK ;
Bagster, DF ;
Mukhraiya, J .
JOURNAL OF AEROSOL SCIENCE, 2002, 33 (07) :999-1008
[6]   THE RELATIONSHIP BETWEEN POWDER INHALER RESISTANCE AND PEAK INSPIRATORY CONDITIONS IN HEALTHY-VOLUNTEERS - IMPLICATIONS FOR IN-VITRO TESTING [J].
CLARK, AR ;
HOLLINGWORTH, AM .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1993, 6 (02) :99-110
[7]  
Coates M.S., 2004, RESP DRUG DELIVERY
[8]   The role of capsule on the performance of a dry powder inhaler using computational and experimental analyses [J].
Coates, MS ;
Fletcher, DF ;
Chan, HK ;
Raper, JA .
PHARMACEUTICAL RESEARCH, 2005, 22 (06) :923-932
[9]   Influence of air flow on the performance of a dry powder inhaler using computational and experimental analyses [J].
Coates, MS ;
Chan, HK ;
Fletcher, DF ;
Raper, JA .
PHARMACEUTICAL RESEARCH, 2005, 22 (09) :1445-1453
[10]  
COATES MS, 2005, P 7 WORLD C CHEM ENG