Plenoptic x-ray microscopy

被引:9
作者
Sowa, Katarzyna M. [1 ]
Kujda, Marcin P. [1 ]
Korecki, Pawel [1 ]
机构
[1] Jagiellonian Univ, Inst Phys, Lojasiewicza 11, PL-30348 Krakow, Poland
关键词
LIGHT-FIELD; CALCIUM-OXALATE; TOMOSYNTHESIS; PHASE; CONTRAST; EXTRACTION; RESOLUTION; STEREO; OPTICS; IMAGE;
D O I
10.1063/1.5131494
中图分类号
O59 [应用物理学];
学科分类号
摘要
Plenoptic cameras use arrays of microlenses to capture multiple views of the same scene in a single compound image. They enable refocusing on different planes and depth estimation. However, until now, all types of plenoptic computational imaging processes have been limited to visible light. We demonstrate an x-ray plenoptic microscope that uses a concentrating microcapillary array instead of a microlens array and can simultaneously acquire from one hundred to one thousand x-ray projections of imaged volumes that are located in the focal spot region of the microcapillary array. Hence, tomographic slices at various depths near the focal plane can be reconstructed in a way similar to tomosynthesis but from a single x-ray exposure. The microscope enables the depth-resolved imaging of small subvolumes in large samples and can be used for the imaging of weakly absorbing artificial and biological objects by means of propagation phase-contrast. Published under license by AIP Publishing.
引用
收藏
页数:5
相关论文
共 54 条
[1]  
Ackerfield J., 2001, Edinburgh Journal of Botany, V58, P259
[2]   SINGLE LENS STEREO WITH A PLENOPTIC CAMERA [J].
ADELSON, EH ;
WANG, JYA .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :99-106
[3]  
[Anonymous], 2005, Tech. Rep. CTSR 2005-02
[4]  
[Anonymous], 1908, J. Phys. Theor. Appl, DOI DOI 10.1051/JPHYSTAP:019080070082100
[5]   Confocal micro-X-ray fluorescence spectroscopy with a liquid metal jet source [J].
Bauer, Leona ;
Lindqvist, Malcolm ;
Foerste, Frank ;
Lundstroem, Ulf ;
Hansson, Bjoern ;
Thiel, Markus ;
Bjeoumikhova, Semfira ;
Groetzsch, Daniel ;
Malzer, Wolfgang ;
Kanngiesser, Birgit ;
Mantouvalou, Ioanna .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (09) :1552-1558
[6]   NANOMETER SPATIAL-RESOLUTION ACHIEVED IN HARD X-RAY-IMAGING AND LAUE DIFFRACTION EXPERIMENTS [J].
BILDERBACK, DH ;
HOFFMAN, SA ;
THIEL, DJ .
SCIENCE, 1994, 263 (5144) :201-203
[7]   Monochromatic Propagation-Based Phase-Contrast Microscale Computed-Tomography System with a Rotating-Anode Source [J].
Brombal, L. ;
Kallon, G. ;
Jiang, J. ;
Savvidis, S. ;
De Coppi, P. ;
Urbani, L. ;
Forty, E. J. ;
Chambers, R. C. ;
Longo, R. ;
Olivo, A. ;
Endrizzi, M. .
PHYSICAL REVIEW APPLIED, 2019, 11 (03)
[8]   EIGER detector: application in macromolecular crystallography [J].
Casanas, Arnau ;
Warshamanage, Rangana ;
Finke, Aaron D. ;
Panepucci, Ezequiel ;
Olieric, Vincent ;
Noell, Anne ;
Tampe, Robert ;
Brandstetter, Stefan ;
Foerster, Andreas ;
Mueller, Marcus ;
Schulze-Briese, Clemens ;
Bunk, Oliver ;
Wang, Meitian .
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY, 2016, 72 :1036-1048
[9]   X-RAY FOCUSING USING SQUARE CHANNEL-CAPILLARY ARRAYS [J].
CHAPMAN, HN ;
NUGENT, KA ;
WILKINS, SW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (06) :1542-1561
[10]   Phase objects in synchrotron radiation hard x-ray imaging [J].
Cloetens, P ;
Barrett, R ;
Baruchel, J ;
Guigay, JP ;
Schlenker, M .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1996, 29 (01) :133-146