High resolution computed tomography of the chest in cystic fibrosis (CF): is simplification of scoring systems feasible?

被引:14
作者
Oikonomou, Anastasia [1 ]
Tsanakas, John [2 ]
Hatziagorou, Elpis [2 ]
Kirvassilis, Fotios [2 ]
Efremidis, Stavros [3 ]
Prassopoulos, Panos [1 ]
机构
[1] Democritus Univ Thrace, Univ Hosp Alexandroupolis, Dept Radiol, Alexandroupolis 68100, Greece
[2] Aristotle Univ Thessaloniki, Ippokratio Hosp Thessaloniki, Dept Pediat 3D, Thessaloniki 54642, Greece
[3] Univ Ioannina, Univ Hosp Ioannina, Dept Radiol, Ioannina 45500, Greece
关键词
cystic fibrosis; lung HRCT; scoring system;
D O I
10.1007/s00330-007-0810-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to simplify HRCT scoring systems (SS) for CF by selecting representative HRCT parameters. Forty-two consecutive patients with CF underwent baseline and follow-up chest HRCT. Three radiologists evaluated 84 HRCTs employing five SS. "Simplified" HRCT SS were formed by selection of parameters exhibiting statistically significant relations with FEV1. Pulmonary function tests (PFTs) and nutrition (IBW%) were recorded. Regression analysis, Pearson correlation and T-test were used for statistical analysis. Three HRCT parameters were selected for the formation of "simplified" HRCT SS (severity of bronchiectasis, bronchial wall thickening, atelectasis-consolidation) using regression analysis. There was excellent correlation between each "simplified" and corresponding complete score (0.892 < r < 0.0967, p < 0.0001) or the remaining four complete scores (0.786 < r < 0.961, p < 0.0001). Strong correlation was found among the five "simplified" scores (0.803 < r < 0.997, p < 0.0001). Comparing baseline complete and "simplified" scores with corresponding follow-up ones, significant worsening was observed (p < 0.0001). PFTs and IBW% did not change significantly. HRCT scores correlated moderately with FVC and FEV1, but there was no correlation with FEF25-75 and IBW%. "Simplified" HRCT SS are as reliable as the complete ones and detect progression of lung disease earlier than clinical parameters. They are easy to use and could be adopted in clinical practice.
引用
收藏
页码:538 / 547
页数:10
相关论文
共 29 条
[1]   CYSTIC-FIBROSIS - SCORING SYSTEM WITH THIN-SECTION CT [J].
BHALLA, M ;
TURCIOS, N ;
APONTE, V ;
JENKINS, M ;
LEITMAN, BS ;
MCCAULEY, DI ;
NAIDICH, DP .
RADIOLOGY, 1991, 179 (03) :783-788
[2]   High-resolution computed tomography in young patients with cystic fibrosis: Distribution of abnormalities and correlation with pulmonary function tests [J].
Brody, AS ;
Klein, JS ;
Molina, PL ;
Quan, J ;
Bean, JA ;
Wilmott, RW .
JOURNAL OF PEDIATRICS, 2004, 145 (01) :32-38
[3]   Scoring systems for CT in cystic fibrosis: Who cares? [J].
Brody, AS .
RADIOLOGY, 2004, 231 (02) :296-298
[4]   Early morphologic changes in the lungs of asymptomatic infants and young children with cystic fibrosis [J].
Brody, AS .
JOURNAL OF PEDIATRICS, 2004, 144 (02) :145-146
[5]   High-resolution computed tomography of the chest in children with cystic fibrosis: support for use as an outcome surrogate [J].
Brody, AS ;
Molina, PL ;
Klein, JS ;
Rothman, BS ;
Ramagopal, M ;
Swartz, DR .
PEDIATRIC RADIOLOGY, 1999, 29 (10) :731-735
[6]  
Castile R, 2000, PEDIATR PULM, V20, pA427
[7]   Progressive damage on high resolution computed tomography despite stable lung function in cystic fibrosis [J].
de Jong, PA ;
Nakano, Y ;
Lequin, MH ;
Mayo, JR ;
Woods, R ;
Paré, PD ;
Tiddens, HAWM .
EUROPEAN RESPIRATORY JOURNAL, 2004, 23 (01) :93-97
[8]   Pulmonary disease assessment in cystic fibrosis:: Comparison of CT scoring systems and value of bronchial and arterial dimension measurements [J].
de Jong, PA ;
Ottink, MD ;
Robben, SGF ;
Lequin, MH ;
Hop, WCJ ;
Hendriks, JJE ;
Paré, PD ;
Tiddens, HAWM .
RADIOLOGY, 2004, 231 (02) :434-439
[9]   Contrast-enhanced 3D MRI of lung perfusion in children with cystic fibrosis -: initial results [J].
Eichinger, Monika ;
Puderbach, Michael ;
Fink, Christian ;
Gahr, Julie ;
Ley, Sebastian ;
Plathow, Christian ;
Tuengerthal, Siegfried ;
Zuna, Ivan ;
Mueller, Frank-Michael ;
Kauczor, Hans-Ulrich .
EUROPEAN RADIOLOGY, 2006, 16 (10) :2147-2152
[10]  
HANSELL DM, 1989, BRIT J RADIOL, V62, P1