Background: There is minimal experience with less rigid syndesmotic fixation devices which may approximate the normal distal tibio-fibular mechanics during healing. This study evaluates the ability of a FiberWire-button implant (Arthrex, Naples, FL) to maintain syndesmotic reduction as compared with a metallic screw. Methods: Ten matched fresh-frozen cadaveric ankle pairs with intact ligaments were tested (12.5 Nm external rotation force) to establish physiologic syndesmotic diastasis. The same force was applied to the ankles after sectioning of the syndesmotic and deltoid ligaments. Within the pairs, each limb was randomized to receive a FiberWire-button implant or a metallic screw (Synthes, Paoli, PA); the ankles were tested for syndesmotic diastasis with progressive external rotation force, from 2.5 Nm to 25 Nm (or failure). Results: There was no significant difference in diastasis amongst pairs with intact or sectioned syndesmosis (p = 0.64 and p = 0.80, respectively). There was a significantly greater diastasis in the FiberWire-button group at all external rotation loads (p < 0.0001). Nine of the ten pairs failed (all through fracture of the distal fibula). There were no hardware failures. The metallic screw group failed at a lower load (mean 15 Nm) compared to the FiberWire-button group (mean 18 Nun, p = 0.0004). The metallic screw group maintained syndesmotic reduction up to 5 Nm of force. Conclusions: The FiberWire-button was unable to maintain syndesmotic reduction of the ankles at any of the forces applied. The ankles fixed with the FiberWire-button demonstrated significantly greater widening of the syndesmosis compared to the screw, at all loads. Clinical Relevance: The FiberWire-button implant may not maintain adequate ankle syndesmotic reduction in the immediate post-operative period relative to a metallic screw.
引用
收藏
页码:49 / 54
页数:6
相关论文
共 34 条
  • [1] Sutures and suture anchors: Update 2003
    Barber, FA
    Herbert, MA
    Richards, DP
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (09) : 985 - 990
  • [2] MECHANICAL CONSIDERATIONS FOR THE SYNDESMOSIS SCREW - A CADAVER STUDY
    BODEN, SD
    LABROPOULOS, PA
    MCCOWIN, P
    LESTINI, WF
    HURWITZ, SR
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (10) : 1548 - 1555
  • [3] DISTAL TIBIOFIBULAR SYNOSTOSIS AFTER MALLEOLAR FRACTURES TREATED USING ABSORBABLE IMPLANTS
    BOSTMAN, OM
    [J]. FOOT & ANKLE, 1993, 14 (01): : 38 - 43
  • [4] TIBIOTALAR JOINT DYNAMICS - INDICATIONS FOR THE SYNDESMOTIC SCREW - A CADAVER STUDY
    BURNS, WC
    PRAKASH, K
    ADELAAR, R
    BEAUDOIN, A
    KRAUSE, W
    [J]. FOOT & ANKLE, 1993, 14 (03): : 153 - 158
  • [5] CHISSELL HR, 1995, J BONE JOINT SURG BR, V77B, P435
  • [6] Ankle fractures involving the fibula proximal to the distal tibiofibular syndesmosis
    Ebraheim, NA
    Mekhail, AO
    Gargasz, SS
    [J]. FOOT & ANKLE INTERNATIONAL, 1997, 18 (08) : 513 - 521
  • [7] EARLY POSTOPERATIVE WEIGHT-BEARING AND MUSCLE-ACTIVITY IN PATIENTS WHO HAVE A FRACTURE OF THE ANKLE
    FINSEN, V
    SAETERMO, R
    KIBSGAARD, L
    FARRAN, K
    ENGEBRETSEN, L
    BOLZ, KD
    BENUM, P
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (01) : 23 - 27
  • [8] HEALING OF THE MEDIAL COLLATERAL LIGAMENT IN RATS - THE EFFECTS OF REPAIR, MOTION, AND SECONDARY STABILIZING LIGAMENTS
    HART, DP
    DAHNERS, LE
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1987, 69A (08) : 1194 - 1199
  • [9] SYNDESMOSIS SPRAINS OF THE ANKLE
    HOPKINSON, WJ
    STPIERRE, P
    RYAN, JB
    WHEELER, JH
    [J]. FOOT & ANKLE, 1990, 10 (06): : 325 - 330
  • [10] Treatment of syndesmotic disruptions of the ankle with bioabsorbable screw fixation
    Hovis, WD
    Kaiser, BW
    Watson, JT
    Bucholz, RW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (01) : 26 - 31