A theoretical framework for comparing noise characteristics of spectral, differential phase-contrast and spectral differential phase-contrast x-ray imaging

被引:11
作者
Mechlem, Korbinian [1 ,2 ]
Sellerer, Thorsten [1 ,2 ]
Viermetz, Manuel [1 ,2 ]
Herzen, Julia [1 ,2 ]
Pfeiffer, Franz [1 ,2 ,3 ,4 ,5 ]
机构
[1] Tech Univ Munich, Dept Phys, Chair Biomed Phys, D-85748 Garching, Germany
[2] Tech Univ Munich, Munich Sch BioEngn, D-85748 Garching, Germany
[3] Tech Univ Munich, Sch Med, Dept Diagnost & Intervent Radiol, D-81675 Munich, Germany
[4] Tech Univ Munich, Klinikum Rechts Isar, D-81675 Munich, Germany
[5] Tech Univ Munich, Inst Adv Study, D-85748 Garching, Germany
基金
欧洲研究理事会;
关键词
spectral; phase-contrast; Cramer-Rao lower bound; noise analysis; x-ray imaging; COUNTING COMPUTED-TOMOGRAPHY; EXPERIMENTAL FEASIBILITY; CT; ABSORPTION; EFFICIENCY; AGENTS;
D O I
10.1088/1361-6560/ab7106
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Spectral and grating-based differential phase-contrast (DPC) x-ray imaging are two emerging technologies that offer additional information compared with conventional attenuation-based x-ray imaging. In the case of spectral imaging, energy-resolved measurements allow the generation of material-specific images by exploiting differences in the energy-dependent attenuation. DPC imaging uses the phase shift that an x-ray wave exhibits when traversing an object as contrast generation mechanism. Recently, we have investigated the combination of these two imaging techniques (spectral DPC imaging) and demonstrated potential advantages compared with spectral imaging. In this work, we present a noise analysis framework that allows the prediction of (co-) variances and noise power spectra for all three imaging methods. Moreover, the optimum acquisition parameters for a particular imaging task can be determined. We use this framework for a performance comparison of all three imaging methods. The comparison is focused on (projected) electron density images since they can be calculated with all three imaging methods. Our study shows that spectral DPC imaging enables the calculation of electron density images with strongly reduced noise levels compared with the other two imaging methods for a large range of clinically relevant pixel sizes. In contrast to conventional DPC imaging, there are no long-range noise correlations for spectral DPC imaging. This means that excessive low frequency noise can be avoided. We confirm the analytical predictions by numerical simulations.
引用
收藏
页数:16
相关论文
共 48 条
[1]  
[Anonymous], 1991, STAT SIGNAL PROCESSI
[2]   Review of hybrid pixel detector readout ASICs for spectroscopic X-ray imaging [J].
Ballabriga, R. ;
Alozy, J. ;
Campbell, M. ;
Frojdh, E. ;
Heijne, E. H. M. ;
Koenig, T. ;
Llopart, X. ;
Marchal, J. ;
Pennicard, D. ;
Poikela, T. ;
Tlustos, L. ;
Valerio, P. ;
Wong, W. ;
Zuber, M. .
JOURNAL OF INSTRUMENTATION, 2016, 11
[3]   PARAMETRIZED X-RAY ABSORPTION IN DIAGNOSTIC-RADIOLOGY FROM MONTE-CARLO CALCULATIONS - IMPLICATIONS FOR X-RAY-DETECTOR DESIGN [J].
BOONE, JM .
MEDICAL PHYSICS, 1992, 19 (06) :1467-1473
[4]   Direct quantitative material decomposition employing grating-based X-ray phase-contrast CT [J].
Braig, Eva ;
Boehm, Jessica ;
Dierolf, Martin ;
Jud, Christoph ;
Guenther, Benedikt ;
Mechlem, Korbinian ;
Allner, Sebastian ;
Sellerer, Thorsten ;
Achterhold, Klaus ;
Gleich, Bernhard ;
Noel, Peter ;
Pfeiffer, Daniela ;
Rummeny, Ernst ;
Herzen, Julia ;
Pfeiffer, Franz .
SCIENTIFIC REPORTS, 2018, 8
[5]   Penalized maximum likelihood reconstruction for x-ray differential phase-contrast tomography [J].
Brendel, Bernhard ;
von Teuffenbach, Maximilian ;
Noel, Peter B. ;
Pfeiffer, Franz ;
Koehler, Thomas .
MEDICAL PHYSICS, 2016, 43 (01) :188-194
[6]   Signal-to-noise ratio in x ray dark-field imaging using a grating interferometer [J].
Chabior, Michael ;
Donath, Tilman ;
David, Christian ;
Schuster, Manfred ;
Schroer, Christian ;
Pfeiffer, Franz .
JOURNAL OF APPLIED PHYSICS, 2011, 110 (05)
[7]   Beam hardening effects in grating-based x-ray phase-contrast imaging [J].
Chabior, Michael ;
Donath, Tilman ;
David, Christian ;
Bunk, Oliver ;
Schuster, Manfred ;
Schroer, Christian ;
Pfeiffer, Franz .
MEDICAL PHYSICS, 2011, 38 (03) :1189-1195
[8]   Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography [J].
Chen, Guang-Hong ;
Zambelli, Joseph ;
Li, Ke ;
Bevins, Nicholas ;
Qi, Zhihua .
MEDICAL PHYSICS, 2011, 38 (02) :584-588
[9]   Experimental feasibility of spectral photon-counting computed tomography with two contrast agents for the detection of endoleaks following endovascular aortic repair [J].
Dangelmaier, Julia ;
Bar-Ness, Daniel ;
Daerr, Heiner ;
Muenzel, Daniela ;
Si-Mohamed, Salim ;
Ehn, Sebastian ;
Fingerle, Alexander A. ;
Kimm, Melanie A. ;
Kopp, Felix K. ;
Boussel, Loic ;
Roessl, Ewald ;
Pfeiffer, Franz ;
Rummeny, Ernst J. ;
Proksa, Roland ;
Douek, Philippe ;
Noel, Peter B. .
EUROPEAN RADIOLOGY, 2018, 28 (08) :3318-3325
[10]   Toward Clinical X-ray Phase-Contrast CT Demonstration of Enhanced Soft-Tissue Contrast in Human Specimen [J].
Donath, Tilman ;
Pfeiffer, Franz ;
Bunk, Oliver ;
Gruenzweig, Christian ;
Hempel, Eckhard ;
Popescu, Stefan ;
Vock, Peter ;
David, Christian .
INVESTIGATIVE RADIOLOGY, 2010, 45 (07) :445-452