Assessing the predictive accuracy of QUICKI as a surrogate index for insulin sensitivity using a calibration model

被引:208
作者
Chen, H [1 ]
Sullivan, G [1 ]
Quon, MJ [1 ]
机构
[1] NIH, Natl Ctr Complementary & Alternat Med, Diabet Unit, Bethesda, MD 20892 USA
关键词
D O I
10.2337/diabetes.54.7.1914
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The quantitative insulin-sensitivity check index (QUICKI) has an excellent linear correlation with the glucose clamp index of insulin sensitivity (SIClamp) that is better than that of many other surrogate indexes. However, correlation between a surrogate and reference standard may improve as variability between subjects in a cohort increases (i.e., with an increased range of values). Correlation may be excellent even when prediction of reference values by the surrogate is poor. Thus, it is important to evaluate the ability of QUICKI to accurately predict insulin sensitivity as determined by the reference glucose clamp method. In the present study, we used a calibration model to compare the ability of QUICKI and other simple surrogates to predict SIClamp. Predictive accuracy was evaluated by both root mean squared error of prediction as well as a more robust leave-one-out cross-validation-type root mean squared error of prediction (CVPE). Based on data from 116 glucose clamps obtained from nonobese, obese, type 2 diabetic, and hypertensive subjects, we found that QUICKI and log (homeostasis model assessment [HOMA]) were both excellent at predicting SIClamp (CVPE = 1.45 and 1.51, respectively) and significantly better than HOMA, 1/HOMA, and fasting insulin (CVPE = 3.17, P < 0.001; 1.67, P < 0.02; and 2.85, P < 0.001, respectively). QUICKI and log(HOMA) also had the narrowest distribution of residuals (measured SIClamp - predicted SIClamp). In a subset of subjects (n = 78) who also underwent a frequently sampled intravenous glucose tolerance test with minimal model analysis, QUICKI was significantly better than the minimal model index of insulin sensitivity (SIMM) at predicting SIClamp (CVPE = 1.54 vs. 1.98, P = 0.001). We conclude that QUICKI and log(HOMA) are among the most accurate surrogate indexes for determining insulin sensitivity in humans.
引用
收藏
页码:1914 / 1925
页数:12
相关论文
共 44 条
  • [1] American Diabetes Association, 2004, Diabetes Care, V27 Suppl 1, pS5, DOI 10.2337/diacare.27.2007.S5
  • [2] Diagnosing insulin resistance by simple quantitative methods in subiects with normal glucose metabolism
    Ascaso, JF
    Pardo, S
    Real, JT
    Lorente, RI
    Priego, A
    Carmena, R
    [J]. DIABETES CARE, 2003, 26 (12) : 3320 - 3325
  • [3] What kind of simple fasting index should be used to estimate insulin sensitivity in humans?
    Bastard, JP
    Rabasa-Lhoret, R
    Maachi, M
    Ducluzeau, PH
    Andreelli, F
    Vidal, H
    Laville, M
    [J]. DIABETES & METABOLISM, 2003, 29 (03) : 285 - 288
  • [4] Bergman RN, 2003, ADV EXP MED BIOL, V537, P1
  • [5] TOWARD PHYSIOLOGICAL UNDERSTANDING OF GLUCOSE-TOLERANCE - MINIMAL-MODEL APPROACH
    BERGMAN, RN
    [J]. DIABETES, 1989, 38 (12) : 1512 - 1527
  • [6] EQUIVALENCE OF THE INSULIN SENSITIVITY INDEX IN MAN DERIVED BY THE MINIMAL MODEL METHOD AND THE EUGLYCEMIC GLUCOSE CLAMP
    BERGMAN, RN
    PRAGER, R
    VOLUND, A
    OLEFSKY, JM
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1987, 79 (03) : 790 - 800
  • [7] Homeostasis model assessment closely mirrors the glucose clamp technique in the assessment of insulin sensitivity - Studies in subjects with various degrees of glucose tolerance and insulin sensitivity
    Bonora, E
    Saggiani, F
    Targher, G
    Zenere, MB
    Alberiche, M
    Monauni, T
    Bonadonna, RC
    Muggeo, M
    [J]. DIABETES CARE, 2000, 23 (01) : 57 - 63
  • [8] Brown P. J., 1993, MEASUREMENT REGRESSI
  • [9] QUICKI is a useful index of insulin sensitivity in subjects with hypertension
    Chen, H
    Sullivan, G
    Yue, LQ
    Katz, A
    Quon, MJ
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2003, 284 (04): : E804 - E812
  • [10] DEFRONZO RA, 1979, AM J PHYSIOL, V237, pE214