Validation of a two-step quality control approach for a large-scale human urine metabolomic study conducted in seven experimental batches with LC/QTOF-MS

被引:11
作者
Demetrowitsch, Tobias J. [1 ]
Petersen, Beate [1 ]
Keppler, Julia K. [1 ]
Koch, Andreas [2 ]
Schreiber, Stefan [3 ]
Laudes, Matthias [3 ]
Schwarz, Karin [1 ]
机构
[1] Univ Kiel, Dept Food Technol, Inst Human Nutr & Food Sci, Kiel, Germany
[2] Univ Kiel, Dept Maritime Physiol, Inst Expt Med, Kiel, Germany
[3] Univ Kiel, Dept Internal Med 1, Kiel, Germany
关键词
human urine; large-scale study; mass spectrometry; metabolomics; nontargeted analysis; PCA; QC approach; QToF; PERFORMANCE LIQUID-CHROMATOGRAPHY; METABONOMIC ANALYSIS; DAY REPRODUCIBILITY; ASCORBIC-ACID; HPLC-MS; HMDB;
D O I
10.4155/bio.14.270
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
After his study of food science at the Rheinische Friedrich-Wilhelms University of Bonn, Tobias J Demetrowitsch obtained his doctoral degree in the research field of metabolomics at the Christian-Albrechts-University of Kiel. The present paper is part of his doctoral thesis and describes an extended strategy to evaluate and verify complex or large-scale experiments and data sets. Large-scale studies result in high sample numbers, requiring the analysis of samples in different batches. So far, the verification of such LC-MS-based metabolomics studies is difficult. Common approaches have not provided a reliable validation procedure to date. This article shows a novel verification process for a large-scale human urine study (analyzed by a LC/QToF-MS system) using a two-step validation procedure. The first step comprises a targeted approach that aims to examine and exclude statistical outliers. The second step consists of a principle component analysis, with the aim of a tight cluster of all quality controls and a second for all volunteer samples. The applied study design provides a reliable two-step validation procedure for large-scale studies and additionally contains an inhouse verification procedure.
引用
收藏
页码:103 / 112
页数:10
相关论文
共 26 条
[1]  
Barnett V, 1994, OUTLIERS OUTLIERS ST
[2]  
Boes T., 2007, EFFECTS LOW LEVEL AN, P1
[3]   A comparison of normalization methods for high density oligonucleotide array data based on variance and bias [J].
Bolstad, BM ;
Irizarry, RA ;
Åstrand, M ;
Speed, TP .
BIOINFORMATICS, 2003, 19 (02) :185-193
[4]  
Committee for Medicinal Products for Human Use (CHMP) EMA, 2011, GUIDELINE BIOANALYTI
[5]  
Dunn WB, 2012, BIOANALYSIS, V4, P2249, DOI [10.4155/BIO.12.204, 10.4155/bio.12.204]
[6]   Evaluation of the repeatability of ultra-performance liquid chromatography-TOF-MS for global metabolic profiling of human urine samples [J].
Gika, Helen G. ;
Macpherson, Euan ;
Theodoridis, Georgios A. ;
Wilson, Ian D. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 871 (02) :299-305
[7]   Within-day reproducibility of an HPLC-MS-Based method for metabonomic analysis: Application to human urine [J].
Gika, Helen G. ;
Theodoridis, Georgios A. ;
Wingate, Julia E. ;
Wilson, Ian D. .
JOURNAL OF PROTEOME RESEARCH, 2007, 6 (08) :3291-3303
[8]  
Gika HG, 2012, BIOANALYSIS, V4, P2239, DOI [10.4155/BIO.12.212, 10.4155/bio.12.212]
[9]   Dimensionality reduction and visualization in principal component analysis [J].
Ivosev, Gordana ;
Burton, Lyle ;
Bonner, Ron .
ANALYTICAL CHEMISTRY, 2008, 80 (13) :4933-4944
[10]   LC-MS/MS systematic toxicological analysis: Comparison of MS/MS spectra obtained with different instruments and settings [J].
Jansen, R ;
Lachatre, G ;
Marquet, P .
CLINICAL BIOCHEMISTRY, 2005, 38 (04) :362-372