Cyclic behavior of bolted connections with different arrangement of bolts

被引:70
作者
Gerami, Mohsen [1 ]
Saberi, Harnid [1 ]
Saberi, Vahid [1 ]
Daryan, Amir Saedi [2 ]
机构
[1] Univ Semnan, Dept Civil Engn, Semnan, Iran
[2] Islamic Azad Univ, North Branch, Tehran, Iran
关键词
Cyclic behavior; Bolted connections; End plate; T-stub; Failure mode; Bolt arrangement; NORTHRIDGE EARTHQUAKE; NANBU EARTHQUAKE; STEEL STRUCTURES; LESSONS;
D O I
10.1016/j.jcsr.2010.11.011
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
During the 1994 Northridge earthquake, relatively poor performance of the bolted web-welded flange connections (BWWFs) was observed. Thereafter, various types of connections such as end plate and T-stub bolted connections were suggested to be used in moment resisting frames that are often used in industrial and tall buildings. In this paper, finite element simulation is used to study and compare the cyclic behavior of fourteen specimens of the mentioned connection type by changing the horizontal and vertical arrangement of bolts. The results show that the moment capacity and the initial rotational stiffness of T-stub bolted connections are higher than that of end plate bolted connections designed based on AISC considering the total energy dissipation of both groups to be approximately equal. It is also evident that the probability of failure mode change in T-stub connections is higher than that of end plate connections under cyclic loading due to the arrangement variation of bolts. Based on the results of this paper, end plate connections are suggested for conditions where the imperfection in construction is probable. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:690 / 705
页数:16
相关论文
共 50 条
[31]   Post Tensioned Tendons for Seismic Retrofitting of Weak Bolted T-stub Connections [J].
Saberi, Vahid ;
Gerami, Mohsen ;
Kheyroddin, Ali .
INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2017, 17 (03) :877-891
[32]   Flange connections with high-strength bolts with technological heredity of bolts [J].
Vatin, N. ;
Gubaydulin, R. G. ;
Tingaev, A. .
MAGAZINE OF CIVIL ENGINEERING, 2020, 99 (07)
[33]   BEHAVIOR OF EXTENDED ENDPLATE CONNECTIONS UNDER CYCLIC LOADING [J].
GHOBARAH, A ;
OSMAN, A ;
KOROL, RM .
ENGINEERING STRUCTURES, 1990, 12 (01) :15-27
[34]   Numerical analyses of corroded bolted connections [J].
Paolo, Zampieri ;
Curtarello, Andrea ;
Maiorana, Emanuele ;
Pellegrino, Carlo .
2ND INTERNATIONAL CONFERENCE ON STRUCTURAL INTEGRITY, ICSI 2017, 2017, 5 :592-599
[35]   Seismic behavior of concrete shear walls with bolted end-plate DfD connections [J].
Ding, Tao ;
Xiao, Jianzhuang ;
Wei, Kaihua ;
Lu, Yujie .
ENGINEERING STRUCTURES, 2020, 214
[36]   Impact of different surface finishes on the serviceability of bolted connections after high temperature aging [J].
Oberst, Marcella ;
Myers, Marjorie ;
Buresch, Isabell ;
Ostendorf, Frank .
2024 IEEE 69TH HOLM CONFERENCE ON ELECTRICAL CONTACTS, HOLM, 2024, :24-31
[37]   Cyclic behavior and reinforcement of moment-resisting bolted glulam joints with cracks [J].
Zhang, Jing ;
Jiang, Jin ;
Xu, Yong ;
Zhang, Maili ;
Mo, Liucheng ;
Zhang, Lecheng .
JOURNAL OF BUILDING ENGINEERING, 2022, 45
[38]   Ultimate tensile behavior of bolted stiffened T-stub connections in progressive collapse resistance [J].
Zhang, Ying ;
Gao, Shan ;
Guo, Lanhui ;
Fu, Feng ;
Wang, Sheliang .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 189
[39]   Experimental study on bearing behavior of glass fiber steel composite plates (GSPs) for bolted connections [J].
Ryu, Jaeho ;
Lee, Chang-Hwan ;
Park, Min Jae ;
Ju, Young K. .
ENGINEERING STRUCTURES, 2019, 186 (170-182) :170-182
[40]   Condition assessment of bolted connections in steel structures using deep learning [J].
Jafari, Faezeh ;
Dorafshan, Sattar .
INNOVATIVE INFRASTRUCTURE SOLUTIONS, 2025, 10 (02)