机构:
United Arab Emirates Univ, Fac Med & Hlth Sci, Dept Med Educ, Al Ain, U Arab EmiratesUnited Arab Emirates Univ, Fac Med & Hlth Sci, Dept Med Educ, Al Ain, U Arab Emirates
Shaban, Sami
[1
]
Marzouqi, Farida
论文数: 0引用数: 0
h-index: 0
机构:
United Arab Emirates Univ, Fac Med & Hlth Sci, Dept Pediat, Al Ain, U Arab EmiratesUnited Arab Emirates Univ, Fac Med & Hlth Sci, Dept Med Educ, Al Ain, U Arab Emirates
Marzouqi, Farida
[2
]
Al Mansouri, Aysha
论文数: 0引用数: 0
h-index: 0
机构:
United Arab Emirates Univ, Fac Med & Hlth Sci, Dept Pediat, Al Ain, U Arab EmiratesUnited Arab Emirates Univ, Fac Med & Hlth Sci, Dept Med Educ, Al Ain, U Arab Emirates
Al Mansouri, Aysha
[2
]
Penefsky, Harvey S.
论文数: 0引用数: 0
h-index: 0
机构:
Publ Hlth Res Inst, Dept Biochem, Newark, NJ 07103 USAUnited Arab Emirates Univ, Fac Med & Hlth Sci, Dept Med Educ, Al Ain, U Arab Emirates
Penefsky, Harvey S.
[3
]
Souid, Abdul-Kader
论文数: 0引用数: 0
h-index: 0
机构:
United Arab Emirates Univ, Fac Med & Hlth Sci, Dept Pediat, Al Ain, U Arab EmiratesUnited Arab Emirates Univ, Fac Med & Hlth Sci, Dept Med Educ, Al Ain, U Arab Emirates
Souid, Abdul-Kader
[2
]
机构:
[1] United Arab Emirates Univ, Fac Med & Hlth Sci, Dept Med Educ, Al Ain, U Arab Emirates
[2] United Arab Emirates Univ, Fac Med & Hlth Sci, Dept Pediat, Al Ain, U Arab Emirates
[3] Publ Hlth Res Inst, Dept Biochem, Newark, NJ 07103 USA
Data acquisition;
Peak detection;
Slope calculation;
Phosphorescence;
Oxygen;
D O I:
10.1016/j.cmpb.2010.04.009
中图分类号:
TP39 [计算机的应用];
学科分类号:
081203 ;
0835 ;
摘要:
Accurate measurements of dissolved O(2) as a function of time have numerous chemical and biological applications. The Pd (II) complex of meso-tetra-(4-sulfonatophenyl)-tetrabenzoporphyrin (Pd phosphor) was used for this purpose. Detection is based on the principle that the phosphorescence of this oxygen probe is inversely related to dissolved O(2) (O(2) quenches the phosphorescence). Biologic samples containing the Pd phosphor were flashed (10/s) with a peak output of 625 nm; emitted light was detected at 800 nm. Amplified pulses of phosphorescence were digitized at 1-2 MHz using an analog/digital converter (PCI-DAS 4020/12 I/O Board) with outputs ranging from 1 to 20 MHz. Assessment revealed a customized program was necessary. Pulses were captured using a developed software at 0.1-4 MHz, depending on the speed of the computer. O(2) concentration was calculated by fitting to an exponential the decay of the phosphorescence. Twelve tasks were identified, which allowed full control and customization of the data acquisition, storage and analysis. The program used Microsoft Visual Basic 6 (VB6), Microsoft Access Database 2007, and a Universal Library component that allowed direct reading from the PCI-DAS 4020/12 I/O Board. It involved a relational database design to store experiments, pulses and pulse metadata, including phosphorescence decay rates. The method permitted reliable measurements of cellular O(2) consumption over several hours. (c) 2010 Elsevier Ireland Ltd. All rights reserved.