Dose optimization: a review of CT imaging for PET attenuation correction

被引:12
作者
Brady, Samuel L. [1 ]
Shulkin, Barry L. [1 ]
机构
[1] St Jude Childrens Res Hosp, Dept Diagnost Imaging, 262 Danny Thomas Pl, Memphis, TN 38105 USA
关键词
CT; PET; Attenuation correction; CT optimization; STATISTICAL ITERATIVE RECONSTRUCTION; POSITRON EMISSION TOMOGRAPHY; MODALITY F-18-FDG PET/CT; INTRAVENOUS CONTRAST; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; TRANSMISSION MEASUREMENTS; RESPIRATORY MOTION; DIAGNOSTIC CT; PEDIATRIC PET;
D O I
10.1007/s40336-017-0232-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Review limitations and benefits of various options for CT-based attenuation correction for PET/CT studies. With the combination of PET and CT, came the combination of patient radiation dose from the two imaging modalities. Modern advances in CT technology provide opportunities to design CT acquisitions for attenuation correction allowing for the optimization of the attenuation correction acquisition for specific clinical purposes. We reviewed published literature, accepted practices, and the authors' experience, to identify and classify various tailored approaches for CT attenuation correction of PET emission data. ImageWisely recommends three broad categories for dose optimization of attenuation correction in PET/CT imaging: (1) attenuation correction at diagnostic CT quality (PET/CTD); (2) attenuation correction for anatomic localization only of PET images (PET/CTAL); and (3) for PET attenuation correction only (PET/CTAC). The advantages, disadvantages, and dosimetry for each approach are considered. Modern dose reduction techniques allow some CTAL and CTAC exams to have a sufficient image quality for anatomic localization at radiation dose levels equivalent to the previous radionuclide attenuation correction method with [68-Ge/68-Ga] transmission sources. Thus, the major justifications for combining diagnostic quality CTD with PET would be to provide excellent anatomic image correlation in the cases, where subtle functional or lesion uptake requires greater localization refinement, and to reduce patient dose by removing the CTAC or CTAL exam in conjunction with a separate diagnostic CT in lieu of a single CTD exam. The choice of method depends on a variety of factors, including institutional and physician preference and experience, and technology availability.
引用
收藏
页码:359 / 371
页数:13
相关论文
共 81 条
[1]   Clinical Workflow Considerations for Implementation of Continuous-Bed-Motion PET/CT [J].
Acuff, Shelley N. ;
Osborne, Dustin .
JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2016, 44 (02) :55-58
[2]   Weight-Based, Low-Dose Pediatric Whole-Body PET/CT Protocols [J].
Alessio, Adam M. ;
Kinahan, Paul E. ;
Manchanda, Vivek ;
Ghioni, Victor ;
Aldape, Lisa ;
Parisi, Marguerite T. .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (10) :1570-1578
[3]   PET/CT scanner instrumentation, challenges, and solutions [J].
Alessio, AM ;
Kinahan, PE ;
Cheng, PM ;
Vesselle, H ;
Karp, JS .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2004, 42 (06) :1017-+
[4]  
Alessio AM, 2012, CT PROTOCOL SELECTIO
[5]  
[Anonymous], 2009, NCRP REPORT, P1
[6]  
Antoch G, 2004, J NUCL MED, V45, p56S
[7]   PET/CT attenuation correction: Breathing lessons [J].
Bacharach, Stephen L. .
JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (05) :677-679
[8]   Transmission scanning in emission tomography [J].
Bailey, DL .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (07) :774-787
[9]   DETERMINATION OF OBJECT CONTOUR FROM PROJECTIONS FOR ATTENUATION CORRECTION IN CRANIAL POSITRON EMISSION TOMOGRAPHY [J].
BERGSTROM, M ;
LITTON, J ;
ERIKSSON, L ;
BOHM, C ;
BLOMQVIST, G .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1982, 6 (02) :365-372
[10]   Attenuation correction in emission tomography using the emission data-A review [J].
Berker, Yannick ;
Li, Yusheng .
MEDICAL PHYSICS, 2016, 43 (02) :807-832