What biomechanical properties of the cornea are relevant for the clinician?

被引:244
作者
Kotecha, Aachal [1 ]
机构
[1] City Univ London, Moorfields Eye Hosp, Dept Optometry, Glaucoma Res Unit, London EC1V 0HB, England
关键词
biomechanics; central corneal thickness; cornea; glaucoma; hysteresis; INTRAOCULAR-PRESSURE MEASUREMENT; COLLAGEN FIBRILS; THICKNESS; STROMA; ORGANIZATION; HYSTERESIS; GLAUCOMA;
D O I
10.1016/j.survophthal.2007.08.004
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Although the effects of central corneal thickness and corneal curvature on intraocular pressure measurement are well known, it has only recently become possible to measure the biomechanical properties of the cornea in vivo. This article reviews the structural and material properties of the cornea and considers the effects of corneal parameters, including biomechanics, on IOP measurement. The role of corneal biomechanics as a potential indicator of the structural integrity of the globe will also be discussed. Current evidence suggests that the importance of corneal biomechanics to the glaucoma clinician rests primarily with its effects on IOP measurement. However, the possibility that corneal biomechanics may give an indication of the structural integrity of the optic nerve head cannot be completely excluded. Further population and longitudinal studies are needed to clarify whether current in vivo measures of corneal biomechanical properties, including corneal hysteresis, prove to be independent predictors of glaucoma susceptibility.
引用
收藏
页码:S109 / S114
页数:6
相关论文
共 30 条
[1]   Central corneal thickness and corneal hysteresis associated with glaucoma damage [J].
Congdon, NG ;
Broman, AT ;
Bandeen-Roche, K ;
Grover, D ;
Quigley, HA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) :868-875
[2]  
Daxer A, 1998, INVEST OPHTH VIS SCI, V39, P644
[3]   Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach [J].
Doughty, MJ ;
Zaman, ML .
SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) :367-408
[4]  
EHLERS N, 1975, ACTA OPHTHALMOL, V53, P652
[5]   Assessment of corneal biomechanical properties and their variation with age [J].
Elsheikh, Ahmed ;
Wang, Defu ;
Brown, Michael ;
Rama, Paolo ;
Campanelli, Marino ;
Pye, David .
CURRENT EYE RESEARCH, 2007, 32 (01) :11-19
[6]   An update on corneal hydration control [J].
Fischbarg, J ;
Maurice, DM .
EXPERIMENTAL EYE RESEARCH, 2004, 78 (03) :537-541
[7]  
Friedenwald JS., 1937, AM J OPHTHALMOL, V20, P985, DOI [10.1016/S0002-9394(37)90425-2, DOI 10.1016/S0002-9394(37)90425-2]
[8]  
GOLDMANN H, 1957, Ophthalmologica, V134, P221
[9]  
Gordon MO, 2002, ARCH OPHTHALMOL-CHIC, V120, P714
[10]   A study of corneal thickness, shape and collagen organisation in keratoconus using videokeratography and X-ray scattering techniques [J].
Hayes, Sally ;
Boote, Craig ;
Tuft, Stephen J. ;
Quantock, Andrew J. ;
Meek, Keith M. .
EXPERIMENTAL EYE RESEARCH, 2007, 84 (03) :423-434