Influence of Exposure Parameters and Implant Position in Peri-Implant Bone Assessment in CBCT Images: An In Vitro Study

被引:1
作者
Sawicki, Pawel [1 ]
Regulski, Piotr [2 ]
Winiarski, Artur [3 ]
Zawadzki, Pawel J. [1 ]
机构
[1] Med Univ Warsaw, Fac Med Dent, Dept Craniomaxillofacial Surg Oral Surg & Implant, PL-02005 Warsaw, Poland
[2] Med Univ Warsaw, Fac Med Dent, Dept Dent & Maxillofacial Radiol, 61 Zwirki Wigury St, PL-02091 Warsaw, Poland
[3] Med Univ Warsaw, Fac Med Dent, Dept Dent Propaedeut & Prophylaxis, PL-02006 Warsaw, Poland
关键词
CBCT; dental implants; buccal bone; peri-implant artifacts; dentistry; BEAM COMPUTED-TOMOGRAPHY; 2017 WORLD WORKSHOP; CONSENSUS REPORT; ACCURACY; EXTRACTION; CLASSIFICATION; PLACEMENT; THICKNESS; DISEASES; SOCKETS;
D O I
10.3390/jcm11133846
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to assess the impact of dimensional distortion and its changes with modification of exposure setting parameters on the measurements of peri-implant bone margin. Ten titanium dental implants (InKone Primo, Global D, Paris, France) were placed in two prepared bovine ribs. Two bone models and an implant-with-transfer model were scanned with 3shape E4 (3shape, Copenhagen, Denmark) laboratory scanner. Cone beam computed tomography (CBCT) images of two bone models were taken with different values of voltage (60, 70, 80, 90 kV), tube current (4, 10 mA) and voxel size (200, 300 mu m). All the data were superimposed using planning software, and the measurements of buccal bone thickness in two selected regions were performed both using CBCT and scan cross-sections. The mean squared error (MSE) being the squared differences between measurements was used in the accuracy assessment of the CBCT device. A one-way ANOVA revealed significant differences between voltage and MSE (p = 0.044), as well as implant position and MSE (p = 0.005). The distortions of measurements depend on bone margin thickness, and the higher the distance to measure, the higher the error. Accurate measurements of buccal bone thickness (MSE below 0.25) were achieved with voltage values of 70, 80, and 90 kV.
引用
收藏
页数:10
相关论文
共 43 条
[1]   Probe penetration in periodontal and peri-implant tissues: An experimental study in the beagle dog [J].
Abrahamsson, Ingemar ;
Soldini, Claudio .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (06) :601-605
[2]   The effect of surgical regenerative treatment for peri-implantitis: A systematic review [J].
Aljohani, Marwan ;
Yong, Sin L. ;
Bin Rahmah, Abdullah .
SAUDI DENTAL JOURNAL, 2020, 32 (03) :109-119
[3]   Natural Bone Healing In Compromised Sockets After Tooth Extraction: Digital Measurement Methods With Cone-Beam Computed Tomography [J].
An, Xueyin ;
Oh, Ji-Hyeon ;
Jeong, Seung-Mi ;
Choi, Byung-Ho .
JOURNAL OF ORAL IMPLANTOLOGY, 2021, 47 (03) :236-241
[4]   Ridge alterations following implant placement in fresh extraction sockets:: an experimental study in the dog [J].
Araújo, MG ;
Sukekava, F ;
Wennström, JL ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2005, 32 (06) :645-652
[5]   Effect of alveolar ridge preservation interventions following tooth extraction: A systematic review and meta-analysis [J].
Avila-Ortiz, Gustavo ;
Chambrone, Leandro ;
Vignoletti, Fabio .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2019, 46 :195-223
[6]   Peri-implant diseases and conditions: Consensus report of workgroup 4 of the 2017 World Workshop on the Classification of Periodontal and Peri-Implant Diseases and Conditions [J].
Berglundh, Tord ;
Armitage, Gary ;
Araujo, Mauricio G. ;
Avila-Ortiz, Gustavo ;
Blanco, Juan ;
Camargo, Paulo M. ;
Chen, Stephen ;
Cochran, David ;
Derks, Jan ;
Figuero, Elena ;
Hammerle, Christoph H. F. ;
Heitz-Mayfield, Lisa J. A. ;
Huynh-Ba, Guy ;
Iacono, Vincent ;
Koo, Ki-Tae ;
Lambert, France ;
McCauley, Laurie ;
Quirynen, Marc ;
Renvert, Stefan ;
Salvi, Giovanni E. ;
Schwarz, Frank ;
Tarnow, Dennis ;
Tomasi, Cristiano ;
Wang, Hom-Lay ;
Zitzmann, Nicola .
JOURNAL OF PERIODONTOLOGY, 2018, 89 :S313-S318
[7]   ASSESSMENT OF BUCCAL BONE SURROUNDING DENTAL IMPLANTS USING A HIGH-FREQUENCY ULTRASOUND SCANNER [J].
Bohner, Lauren ;
Habor, Daniel ;
Tortamano, Pedro ;
Radermacher, Klaus ;
Wolfart, Stefan ;
Marotti, Juliana .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (06) :1427-1434
[8]   Substitutes for human cadaveric hone in maxillofacial rigid fixation research [J].
Bredbenner, TL ;
Haug, RH .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2000, 90 (05) :574-580
[9]   10-Year Survival and Success Rates of 511 Titanium Implants with a Sandblasted and Acid-Etched Surface: A Retrospective Study in 303 Partially Edentulous Patients [J].
Buser, Daniel ;
Janner, Simone F. M. ;
Wittneben, Julia-Gabriela ;
Braegger, Urs ;
Ramseier, Christoph A. ;
Salvi, Giovanni E. .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (06) :839-851
[10]   Ridge Alterations Post-extraction in the Esthetic Zone: A 3D Analysis with CBCT [J].
Chappuis, V. ;
Engel, O. ;
Reyes, M. ;
Shahim, K. ;
Nolte, L. -P. ;
Buser, D. .
JOURNAL OF DENTAL RESEARCH, 2013, 92 (S12) :195S-201S