Experimental and modelling of vapour-liquid equilibria of ternary systems {HCOOK plus [Emim]Ac + H2O}, {HCOOK plus [Emim]Br + H2O}, {HCOOK plus [Emim]Cl + H2O}, and {HCOOK + [Emim]NO3 + H2O}

被引:7
作者
Ding, Yaqi [1 ]
Gao, Neng [2 ]
Li, Nian [3 ]
Chen, Guangming [1 ]
Xuan, Yongmei [2 ]
机构
[1] Zhejiang Univ, Inst Refrigerat & Cryogen, Key Lab Refrigerat & Cryogen Technol Zhejiang Pro, Hangzhou 310027, Peoples R China
[2] Zhejiang Univ, Ningbo Inst Technol, Ningbo 315100, Peoples R China
[3] Zhejiang Univ, Ningbo Res Inst, Ningbo 315100, Peoples R China
基金
中国国家自然科学基金;
关键词
Absorption; Dehumidification; Potassium formate; Ionic liquid; Vapour-liquid equilibria; ABSORPTION HEAT TRANSFORMER; PRESSURE MEASUREMENT; IONIC LIQUIDS; THERMOPHYSICAL PROPERTIES; LITHIUM BROMIDE; BINARY-MIXTURES; WORKING FLUIDS; WATER; PREDICTION; BEHAVIOR;
D O I
10.1016/j.jct.2021.106503
中图分类号
O414.1 [热力学];
学科分类号
摘要
The vapour liquid equilibrium (VLE) data of four ternary solutions HCOOK + [Emim]Ac /[Emim]Br / [Emim]Cl / [Emim]NO3 + H2O were measured using the boiling method at the temperatures from 305.78 K to 387.08 K, at solute (HCOOK + IL) mass fractions (w) between 0.2 and 0.5. A total of 234 data points (w = 0 included) were obtained and correlated with empirical Antoine-type equations. The absolute average relative deviations (AARD %) between calculated and measured vapour pressures were 0.58%, 0.50%, 0.49%, 0.63%, respectively, which showed good agreement. The comparison of the experimental and standard data and combined uncertainties of the experimental data confirmed good reliability of the experimental method and apparatus. The four ternary solutions with ILs as additives have lower vapour pressure compared to the corresponding binary solutions without ILs. The results showed that the four ternary solutions of HCOOK + [Emim]Ac / [Emim]Br / [Emim]Cl / [Emim]NO3 + H2O can be the alternatives for traditional dehumidification and absorption media. [Emim]CI has the best ability to reduce the vapour pressure of HCOOK + H2O at the solute (HCOOK + IL) mass fraction of 0.4 and 0.5. The [Emim]Ac has the most effect reducing the vapour pressure of HCOOK + H2O at the solute (HCOOK + IL) mass fraction of 0.3. (C) 2021 Elsevier Ltd.
引用
收藏
页数:12
相关论文
共 30 条
[1]  
Atkinson S, 1998, US Patent, Patent No. [5,846,450, 5846450]
[2]   Vapor Pressure Measurements of NaHCOO + H2O and KHCOO + H2O from 278 to 308 K and Representation with an Ion Interaction (Pitzer) Model [J].
Beyer, Roland ;
Steiger, Michael .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2010, 55 (02) :830-838
[5]   Vapor pressures, densities, and viscosities of the (water plus lithium bromide plus sodium formate) system and (water plus lithium bromide plus potassium formate) system [J].
De Lucas, A ;
Donate, M ;
Rodríguez, JF .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2003, 48 (01) :18-22
[6]   Absorption of water vapor into new working fluids for absorption refrigeration systems [J].
De Lucas, Antonio ;
Donate, Marina ;
Rodriguez, Juan F. .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2007, 46 (01) :345-350
[7]   Measurement and prediction of vapor-liquid equilibria of ternary systems containing ionic liquids [J].
Döker, M ;
Gmehling, J .
FLUID PHASE EQUILIBRIA, 2005, 227 (02) :255-266
[8]   A THEORETICAL BASIS FOR THE ANTOINE VAPOR PRESSURE EQUATION [J].
GUTMANN, F ;
SIMMONS, LM .
JOURNAL OF CHEMICAL PHYSICS, 1950, 18 (05) :696-697
[9]   Vapor Pressure Measurement of the Ternary Systems H2O + LiBr + [Dmim]Cl, H2O + LiBr + [Dmim]BF4, H2O + LiCl + [Dmim]Cl, and H2O + LiCl + [Dmim]BF4 [J].
Li Jing ;
Zheng Danxing ;
Fan Lihua ;
Wu Xianghong ;
Dong Li .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2011, 56 (01) :97-101
[10]   Experimental and theoretical analysis of heat and mass transfer in a packed column dehumidifier/regenerator with liquid desiccant [J].
Longo, GA ;
Gasparella, A .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2005, 48 (25-26) :5240-5254