Effect of a floating conductor on discharge characteristics of a long air gap under switching impulse

被引:15
作者
Gao, Jiachen [1 ,2 ]
Wang, Linong [1 ]
Wu, Shaocheng [1 ]
Xie, Cheng [1 ]
Tan, Qipeng [1 ]
Ma, Guoqiang [1 ]
Tueraili, Hayinaer [1 ]
Song, Bin [1 ]
机构
[1] Wuhan Univ, Sch Elect Engn & Automat, Wuhan 430072, Peoples R China
[2] Univ Bologna, Dept Elect Elect & Informat Engn Guglielmo Marcon, I-40136 Bologna, Italy
关键词
Discharge characteristics; Floating conductor; Live working; Long air gap; BREAKDOWN;
D O I
10.1016/j.elstat.2021.103629
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Live working is an important means for the maintenance of transmission lines. During the process of entering the equipotential, the live working lineman is a floating conductor, which affects the discharge characteristics of the air gap of the transmission line. In order to improve the safety protection of linemen, the effect of a floating conductor on discharge characteristics of a long air gap under positive switching impulse was investigated. In this paper, an experiment platform of long air gaps with floating conductors was built, and the breakdown voltage and discharge progress were studied. The experimental results showed the effect of the rod-shaped electrodes and the electrodes with rod-shaped protrusions on the breakdown voltage of the air gaps, as well as the discharge process of the air gaps when the floating electrodes were at different positions. The research conclusions can provide a theoretical basis for discharge mechanism and live working.
引用
收藏
页数:6
相关论文
共 33 条
[1]  
An Y., 2016, THESIS JILIN U CHANG
[2]   A consistent approach to estimate the breakdown voltage of high voltage electrodes under positive switching impulses [J].
Arevalo, L. ;
Wu, D. ;
Jacobson, B. .
JOURNAL OF APPLIED PHYSICS, 2013, 114 (08)
[3]  
ASTM, 2017, ASTM International D2487-17
[4]  
Baldo G., 1989, 6 ISH NEW ORL
[5]   Experimental Study on Branch and Diffuse Type of Streamers in Leader Restrike of Long Air Gap Discharge [J].
Chen She ;
Zeng Rong ;
Zhuang Chijie ;
Zhou Xuan ;
Ding Yujian .
PLASMA SCIENCE & TECHNOLOGY, 2016, 18 (03) :305-310
[6]   The dynamic expansion of leader discharge channels under positive voltage impulse with different rise times in long air gap: Experimental observation and simulation results [J].
Cui, Yingzhe ;
Zhuang, Chijie ;
Zhou, Xuan ;
Zeng, Rong .
JOURNAL OF APPLIED PHYSICS, 2019, 125 (11)
[7]   Leader channel models for long air positive electrical discharges [J].
Diaz, Oscar ;
Arevalo, Liliana ;
Cooray, Vernon .
JOURNAL OF ELECTROSTATICS, 2015, 76 :208-215
[8]   Thermal Characteristics of Positive Leaders under Different Electrode Terminals in a Long Air Gap [J].
Du, Mingxing ;
Tang, Yu ;
Li, Min ;
Zou, Jiayong ;
Ma, Yigang ;
Sun, Jinyu ;
Liu, Lei ;
Zeng, Qingguo .
ENERGIES, 2019, 12 (21)
[9]   Modelling for switching impulse breakdown of live working gaps between equipotential worker and transmission towers [J].
Fang, Yaqi ;
Wang, Linong ;
Li, Rui ;
Gao, Jiachen ;
Song, Bin ;
Liu, Kai .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (07) :1271-1278
[10]   A Modified Model for Discharge Voltage of AC Transmission Line-Tower Air Gaps [J].
Fang, Yaqi ;
Wang, Linong ;
Li, Rui ;
Zhang, Qiushi ;
Gao, Jiachen ;
Song, Bin .
IEEE ACCESS, 2019, 7 :71472-71480