Retrograde leak point pressure measurement improves outcomes of the Virtue male sling for postprostatectomy incontinence

被引:6
作者
Sourial, Michael W. [1 ]
Richard, Patrick O. [1 ,2 ]
Morisset, Julie [3 ]
Jundi, Mazen [3 ]
Tu, Le Mai [1 ]
机构
[1] Univ Sherbrooke, Ctr Hosp Univ Sherbrooke, Div Urol, Dept Surg,Fac Med & Sci Sante, Sherbrooke, PQ, Canada
[2] CHUS, Ctr Rech, Sherbrooke, PQ, Canada
[3] Ctr Hosp Affilie Univ Reg, CSSS Trois Riviere, Dept Surg, Div Urol, Trois Rivieres, PQ, Canada
来源
CUAJ-CANADIAN UROLOGICAL ASSOCIATION JOURNAL | 2017年 / 11卷 / 07期
关键词
ARTIFICIAL URINARY SPHINCTER; RADICAL RETROPUBIC PROSTATECTOMY; STRESS-INCONTINENCE; CONTINENCE; EXPERIENCE;
D O I
10.5489/cuaj.4381
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Introduction: We aimed to compare the efficacy of two different sling tensioning approaches, and to report our experience, including safety and impact on quality of life (QoL) of the Virtue (R) male sling for the treatment of postprostatectomy incontinence (PPI). Methods: From our prospectively maintained database, we retrospectively identified all men treated with the Virtue male sling for PPI between March 2009 and February 2014 by two urologists in two institutions. Baseline demographic data and the sling tensioning method were abstracted from the database. Likewise, the Patient Global Impression of Improvement (PGI-I) scale, severity of incontinence, and clinical outcomes were also abstracted. Results: 48 patients were treated with the Virtue quadratic male sling. Sling tensioning was done using cystoscopy in the first 18 patients (Group 1), while per-operative retrograde leak point pressure (RLPP) measurement was done in the last 30 patients (Group 2). The median (interquartile range [IQR]) followup from the day of surgery was 22 (15-41) months. At the last followup visit, 7 (39%) patients in Group 1 were cured or improved of their PPI, compared to 21 (70%) patients in Group 2 (p=0.03). The final median (IQR) RLPP in these patients was 41 (37-48) cm H2O. Transient pain was the most common adverse event, occurring in 23 (48%) of patients. Twenty-one (70%) patients in Group 2 were "much better" or "very much better" with their device, compared to 7 (39%) in Group 1 (p=0.0008). Conclusions: The Virtue male sling is a valuable treatment option for PPI. Per-operative RLPP measurement significantly improves cure and satisfaction rates.
引用
收藏
页码:E271 / E276
页数:6
相关论文
共 17 条
  • [1] Patient self-reporting questionnaire on urological morbidity and bother after radical retropubic prostatectomy
    Augustin, H
    Pummer, K
    Daghofer, F
    Habermann, H
    Primus, G
    Hubmer, G
    [J]. EUROPEAN UROLOGY, 2002, 42 (02) : 112 - 117
  • [2] Retrograde perfusion sphincterometry with a flexible cystoscope: Method of troubleshooting the AMS 800
    Choe, JM
    Battino, BS
    Bell, TE
    [J]. UROLOGY, 2000, 56 (02) : 317 - 319
  • [3] The Virtue Sling-A New Quadratic Sling for Postprostatectomy Incontinence-Results of a Multinational Clinical Trial
    Comiter, Craig V.
    Rhee, Eugene Y.
    Tu, Le-Mai
    Herschorn, Sender
    Nitti, Victor W.
    [J]. UROLOGY, 2014, 84 (02) : 433 - 438
  • [4] A New Quadratic Sling for Male Stress Incontinence: Retrograde Leak Point Pressure as a Measure of Urethral Resistance
    Comiter, Craig V.
    Nitti, Victor
    Elliot, Christopher
    Rhee, Eugene
    [J]. JOURNAL OF UROLOGY, 2012, 187 (02) : 563 - 568
  • [5] Virtue male sling for post-prostatectomy stress incontinence: a prospective evaluation and mid-term outcomes
    Ferro, Matteo
    Bottero, Danilo
    D'Elia, Carolina
    Matei, Deliu Victor
    Cioffi, Antonio
    Cozzi, Gabriele
    Serino, Alessandro
    Cordima, Giovanni
    Bianchi, Roberto
    Incarbone, Piero Giacomo
    Brescia, Antonio
    Musi, Gennaro
    Fusco, Ferdinando
    Detti, Serena
    Mirone, Vincenzo
    de Cobelli, Ottavio
    [J]. BJU INTERNATIONAL, 2017, 119 (03) : 482 - 488
  • [6] Artificial urinary sphincter for post-radical prostatectomy urinary incontinence: Long-term subjective results
    Gousse, AE
    Madjar, S
    Lambert, MM
    Fishman, IJ
    [J]. JOURNAL OF UROLOGY, 2001, 166 (05) : 1755 - 1758
  • [7] Adjustable bulbourethral male sling: experience after 101 cases of moderate-to-severe male stress urinary incontinence
    Huebner, Wilhelm A.
    Gallistl, Helmut
    Rutkowski, Michael
    Huber, Erik R.
    [J]. BJU INTERNATIONAL, 2011, 107 (05) : 777 - 782
  • [8] Quality of life and patient satisfaction after artificial urinary sphincter
    Kahlon, Bhavneet
    Baverstock, Richard J.
    Carlson, Kevin V.
    [J]. CUAJ-CANADIAN UROLOGICAL ASSOCIATION JOURNAL, 2011, 5 (04): : 268 - 272
  • [9] Long-term durability and functional outcomes among patients with artificial urinary sphincters: A 10-year retrospective review from the University of Michigan
    Kim, Simon P.
    Sarmast, Zubair
    Daignault, Stephanie
    Faerber, Gary J.
    McGuire, Edward J.
    Latini, Jerilyn M.
    [J]. JOURNAL OF UROLOGY, 2008, 179 (05) : 1912 - 1916
  • [10] Artificial Urinary Sphincter Versus Male Sling for Post-Prostatectomy Incontinence-What Do Patients Choose?
    Kumar, Angelish
    Litt, Elana Rosenberg
    Ballert, Katie N.
    Nitti, Victor W.
    [J]. JOURNAL OF UROLOGY, 2009, 181 (03) : 1231 - 1235