Changes in knee kinematics reflect the articular geometry after arthroplasty

被引:100
作者
Bull, Anthony M. J. [2 ]
Kessler, Oliver [3 ]
Alam, Mahbub [1 ,4 ]
Amis, Andrew A. [1 ,5 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Mech Engn, London SW7 2AZ, England
[2] Univ London Imperial Coll Sci Technol & Med, Dept Bioengn, London SW7 2AZ, England
[3] Stryker Orthopaed, Thalwil, Switzerland
[4] St Richards Hosp, Chichester, England
[5] Univ London Imperial Coll Sci Technol & Med, Dept Musculoskeletal Surg, London SW7 2AZ, England
关键词
D O I
10.1007/s11999-008-0440-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We hypothesized changes in rotations and translations after TKA with a fixed-bearing anterior cruciate ligament (ACL)-sacrificing but posterior cruciate ligament (PCL)-retaining design with equal-sized, circular femoral condyles would reflect the changes of articular geometry. Using 8 cadaveric knees, we compared the kinematics of normal knees and TKA in a standardized navigated position with defined loads. The quadriceps was tensed and moments and drawer forces applied during knee flexion-extension while recording the kinematics with the navigation system. TKA caused loss of the screw-home; the flexed tibia remained at the externally rotated position of normal full knee extension with considerably increased external rotation from 63 degrees to 11 degrees extension. The range of internal-external rotation was shifted externally from 30 degrees to 20 degrees extension. There was a small tibial posterior translation from 40 degrees to 90 degrees flexion. The varus-valgus alignment and laxity did not change after TKA. Thus, navigated TKA provided good coronal plane alignment but still lost some aspects of physiologic motion. The loss of tibial screw-home was related to the symmetric femoral condyles, but the posterior translation in flexion was opposite the expected change after TKA with the PCL intact and the ACL excised. Thus, the data confirmed our hypothesis for rotations but not for translations. It is not known whether the standard navigated position provides the best match to physiologic kinematics.
引用
收藏
页码:2491 / 2499
页数:9
相关论文
共 46 条
  • [1] Aglietti P, 1988, J Arthroplasty, V3, P17, DOI 10.1016/S0883-5403(88)80049-4
  • [2] In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties
    Banks, SA
    Markovich, GD
    Hodge, WA
    [J]. JOURNAL OF ARTHROPLASTY, 1997, 12 (03) : 297 - 304
  • [3] Implant design affects knee arthroplasty kinematics during stair-stepping
    Banks, SA
    Hodge, WA
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (426) : 187 - 193
  • [4] Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy
    Banks, SA
    Hodge, WA
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (06) : 638 - 649
  • [5] Barrack RL, 2001, CLIN ORTHOP RELAT R, P46
  • [6] Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty - Influence of posterior condylar offset
    Bellemans, J
    Banks, S
    Victor, J
    Vandenneucker, H
    Moemans, A
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B : 50 - 53
  • [7] BERGER RA, 1993, CLIN ORTHOP RELAT R, P40
  • [8] Malrotation causing patellofemoral complications after total knee arthroplasty
    Berger, RA
    Crossett, LS
    Jacobs, JJ
    Rubash, HE
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (356) : 144 - 153
  • [9] Berger RA, 2001, CLIN ORTHOP RELAT R, P196
  • [10] THE ENVELOPE OF PASSIVE KNEE-JOINT MOTION
    BLANKEVOORT, L
    HUISKES, R
    DELANGE, A
    [J]. JOURNAL OF BIOMECHANICS, 1988, 21 (09) : 705 - +