Shaker testing; Non-ductile reinforced concrete frame; Fiber-reinforced polymer (FRP) jacketing system; Soft-story mechanism; Seismic strengthening; ENHANCED SHEAR-STRENGTH; MODIFIED COMPRESSION MEMBERS; BRIDGE COLUMNS; SEISMIC RESISTANCE; CONFINED CONCRETE; COMPOSITE JACKETS; GRAVITY LOADS; RC COLUMNS; BEHAVIOR; PERFORMANCE;
D O I
10.1016/j.engstruct.2016.07.016
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Many existing reinforced concrete buildings designed in accordance with pre-1971 codes are generally dominated by weak column-strong beam behavior under seismic loading due to inadequate reinforcement detailing. This behavior can lead to premature failure under seismic loads from damage concentrated in the first story of the structure. This paper presents the results of an experimental investigation into the seismic response of a full-scale, two-story non-ductile reinforced concrete frame. The frame was retrofitted with a fiber-reinforced polymer jacketing system on the first story columns to mitigate seismic vulnerability. Shake weight testing was performed to investigate the dynamic performance of the retrofitted building structure in terms of the modal response, inter-story drift, and effectiveness of the fiber-reinforced polymer jacketing system. The results demonstrate that the retrofit scheme helped develop a more uniform story drift distribution, working to counter the soft-story mechanism commonly found in reinforced concrete frames designed during this period. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:244 / 253
页数:10
相关论文
共 57 条
[1]  
ACI (American Concrete Institute), 1963, 31863 ACI
[2]   Influence of edge sharpness on the strength of square concrete columns confined with FRP composite laminates [J].
Al-Salloum, Yousef A. .
COMPOSITES PART B-ENGINEERING, 2007, 38 (5-6) :640-650
[3]  
[Anonymous], 2020, STANDARD TEST METHOD
[4]  
[Anonymous], 2000, Prestandard and Commentary for the Seismic Rehabilitation of Buildings
[5]  
[Anonymous], 2014, D3039 ASTM
[6]  
[Anonymous], 2013, ASTM C109
[7]  
ASCE, 2014, ASCE/SEI 41-13
[8]  
ASTM, 2015, A615 ASTM
[9]  
AYCARDI LE, 1994, ACI STRUCT J, V91, P552
[10]  
Beres A., 1996, EARTHQ SPECTRA, V12, P185, DOI DOI 10.1193/1.1585876