Matched-pair total knee arthroplasty retrieval analysis: Oxidized zirconium vs. CoCrMo

被引:32
作者
Heyse, Thomas J. [1 ]
Chen, Dan X. [2 ]
Kelly, Natalie [2 ]
Boettner, Friedrich [3 ]
Wright, Timothy M. [2 ]
Haas, Steven B. [3 ]
机构
[1] Univ Hosp Marburg, Dept Orthoped & Rheumatol, D-35043 Marburg, Germany
[2] Hosp Special Surg, Dept Biomech, New York, NY 10021 USA
[3] Hosp Special Surg, Dept Biomech, Adult Reconstruct & Joint Replacement Div, New York, NY 10021 USA
关键词
Oxidized zirconium; Oxinium; CoCrMo; Polyethylene; TKA; POLYETHYLENE WEAR; FEMORAL COMPONENTS; BEARING SURFACES; SIMULATOR; DEBRIS; METAL;
D O I
10.1016/j.knee.2010.08.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Oxidized zirconium (OxZr) was introduced to serve as a ceramic surface for femoral components in TKA. The aim of this study was to compare retrieved OxZr components and corresponding PE inserts in matched comparison with conventional cobalt/chrome/molybdenum alloy (CoCrMo). Eleven retrieved posterior stabilized TKA with an OxZr femoral component were included. This included 6 implants from an earlier preliminary study. From a cohort of 56 retrieved TKA with conventional CoCrMo femoral components, pairs were matched according to duration of implantation, patient age, reason for revision, and BMI. Polyethylene inlays and femoral components were optically scored for in vivo damage. The average damage score of the tibial PE inserts was significantly lower with OxZr components (p = 0.01). Mainly burnishing and scratches were found. The average wear score in the visual analysis of the femoral components was significantly lower for the OxZr as well (p = 0.005). Femoral components made of OxZr were less sensitive to in vivo damage and corresponding PE inlays also showed less damage than CoCrMo components. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:448 / 452
页数:5
相关论文
共 17 条
  • [1] Validation of a micro-CT technique for measuring volumetric wear in retrieved acetabular liners
    Bowden, AE
    Kurtz, SM
    Edidin, AA
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 75B (01) : 205 - 209
  • [2] DAVIDSON JA, 1994, BIO-MED MATER ENG, V4, P213
  • [3] DAVIDSON JA, 1993, CLIN ORTHOP RELAT R, P361
  • [4] Oxidized zirconium femoral components reduce polyethylene wear in a knee wear simulator
    Ezzet, KA
    Hermida, JC
    Colwell, CW
    D'Lima, DD
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) : 120 - 124
  • [5] Wear, debris, and biologic activity of cross-linked polyethylene in the knee - Benefits and potential concerns
    Fisher, J
    McEwen, HMJ
    Tipper, JL
    Galvin, AL
    Ingram, J
    Kamali, A
    Stone, MH
    Ingham, E
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) : 114 - 119
  • [6] Sensitivity to implant materials in patients with total knee arthroplasties
    Granchi, Donatella
    Cenni, Elisabetta
    Tigani, Domenico
    Trisolino, Giovanni
    Baldini, Nicola
    Giunti, Armando
    [J]. BIOMATERIALS, 2008, 29 (10) : 1494 - 1500
  • [7] Polyethylene particles of a 'critical size' are necessary for the induction of cytokines by macrophages in vitro
    Green, TR
    Fisher, J
    Stone, M
    Wroblewski, BM
    Ingham, E
    [J]. BIOMATERIALS, 1998, 19 (24) : 2297 - 2302
  • [8] Retrieval Analysis of Femoral Zirconium Components in Total Knee Arthroplasty Preliminary Results
    Heyse, Thomas J.
    Davis, Jack
    Haas, Steven B.
    Chen, Dan X.
    Wright, Timothy M.
    Laskin, Richard S.
    [J]. JOURNAL OF ARTHROPLASTY, 2011, 26 (03) : 445 - 450
  • [9] RETRIEVAL ANALYSIS OF TOTAL KNEE PROSTHESES - A METHOD AND ITS APPLICATION TO 48 TOTAL CONDYLAR PROSTHESES
    HOOD, RW
    WRIGHT, TM
    BURSTEIN, AH
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1983, 17 (05): : 829 - 842
  • [10] Cemented ceramic YMCK total knee arthroplasty in patients with severe rheumatoid arthritis
    Koshino, T
    Okamoto, R
    Takagi, T
    Yamamoto, K
    Saito, T
    [J]. JOURNAL OF ARTHROPLASTY, 2002, 17 (08) : 1009 - 1015