Measurement and analysis of switching transients in 500kV substations

被引:0
|
作者
Zhang, WD [1 ]
Cui, X [1 ]
Wang, S [1 ]
Gu, XS [1 ]
机构
[1] N China Elect Power Univ, Baoding 071003, Hebei, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In high voltage substations, secondary equipments placed in the switchyard and inside the control house can be highly sensitive to the transient electromagnetic disturbances due to switching operations. In order to evaluate transient electromagnetic environments (EME) and provide guidance for better immunity design of secondary equipments, it is necessary to measure and analyze these transient electromagnetic disturbances. During three new 500kV substations powered on, many transient electromagnetic disturbances were measured and recorded. Based on FFT transform, the analysis program was developed and used to analyze characteristics of the disturbances. The results are summarized. Comparisons with IEC61000-4 series standards are made and recommendations are given in this paper.
引用
收藏
页码:391 / 393
页数:3
相关论文
共 50 条
  • [11] Fuzzy Comprehensive Evaluation on the Harmfulness of Magnetic Field in 500kv Substations to Health of Workers
    Wang, Jing
    Zhao, Xin
    Yang, Hongjian
    Gao, Yang
    Chen, Tao
    PROCEEDINGS OF THE 2017 2ND INTERNATIONAL CONFERENCE ON MATERIALS SCIENCE, MACHINERY AND ENERGY ENGINEERING (MSMEE 2017), 2017, 123 : 963 - 966
  • [12] Measurement and Analysis on Electromagnetic Shielding effectiveness of a 500kV UPFC Valve Hall
    Ding, Zhifeng
    Liu, Liang
    Liu, Yinying
    Liu, Xiaofan
    He, Ri
    Hu, Yifan
    Jiao, Chongqing
    2017 IEEE 5TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC-BEIJING), 2017,
  • [13] Brightness Measurement of 500kV Electron Microscope Gun
    Shimoyama, Hiroshi
    Ohshita, Akinori
    Maruse, Susumu
    Minamikawa, Yoshihisa
    1600, Oxford University Press (21):
  • [14] Analysis on lightning overvoltage of 500kV substation
    Shao Yu
    Shao Ming
    Shi Feng
    Wang Kun
    MECHATRONICS, ROBOTICS AND AUTOMATION, PTS 1-3, 2013, 373-375 : 1541 - 1545
  • [15] Application of controlled switching to 500kV shunt reactor current interruption
    Kobayashi, T
    Tsukao, S
    Ohno, I
    Koshizuka, T
    Nishiwaki, S
    Miyake, N
    Matsushita, K
    Saida, T
    2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 1930 - 1930
  • [16] BRIGHTNESS MEASUREMENT OF 500KV ELECTRON-MICROSCOPE GUN
    SHIMOYAM.H
    OHSHITA, A
    MARUSE, S
    MINAMIKA.Y
    JOURNAL OF ELECTRON MICROSCOPY, 1972, 21 (02): : 119 - &
  • [17] Measurement of very fast transient overvoltage in 500kV GIS
    Sun, Wei
    Wang, Yun
    Wu, Zengyao
    Shi, Baozhuang
    Zhang, Wenyuan
    Gaoya Dianqi/High Voltage Apparatus, 34 (04): : 11 - 14
  • [18] DC Side Harmonic Measurement of ±500kV Converter Station
    Xu, Xueqin
    Liu, Zichao
    Sun, Hao
    INTEGRATED FERROELECTRICS, 2020, 207 (01) : 86 - 95
  • [19] ANALOG COMPUTER STUDY OF SWITCHING SURGE TRANSIENTS FOR A 500-KV SYSTEM
    SABATH, J
    SMITH, HM
    JOHNSON, RC
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1966, PA85 (01): : 1 - &
  • [20] Analysis of autotransformer common winding operational conditions in 500 kV substations
    Hou, You-Tao
    Zhang, Li-Li
    Dianli Zidonghua Shebei / Electric Power Automation Equipment, 2006, 26 (11): : 43 - 45