Measurement and analysis of switching transients in 500kV substations

被引:0
|
作者
Zhang, WD [1 ]
Cui, X [1 ]
Wang, S [1 ]
Gu, XS [1 ]
机构
[1] N China Elect Power Univ, Baoding 071003, Hebei, Peoples R China
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In high voltage substations, secondary equipments placed in the switchyard and inside the control house can be highly sensitive to the transient electromagnetic disturbances due to switching operations. In order to evaluate transient electromagnetic environments (EME) and provide guidance for better immunity design of secondary equipments, it is necessary to measure and analyze these transient electromagnetic disturbances. During three new 500kV substations powered on, many transient electromagnetic disturbances were measured and recorded. Based on FFT transform, the analysis program was developed and used to analyze characteristics of the disturbances. The results are summarized. Comparisons with IEC61000-4 series standards are made and recommendations are given in this paper.
引用
收藏
页码:391 / 393
页数:3
相关论文
共 50 条
  • [1] Simulation and Analysis of Current Distribution in 500kV Substations
    Zhao, Wenbin
    Cao, Lu
    Wang, Baohua
    Yang, Luming
    Li, Jianhua
    Zhuang, Kanqin
    Zhang, Yan
    Li, Qingquan
    Han, Mingming
    INTERNATIONAL CONFERENCE ON ELECTRICAL, CONTROL AND AUTOMATION (ICECA 2014), 2014, : 515 - 521
  • [2] Measurement and Analysis of the Switching Transients in 500 kV Pumped Storage Power Plants
    Wang, Wei
    Ma, Guo-Ming
    Liu, Hao
    Han, Wei-Xing
    Shi, Rong-Bin
    Wang, Lei
    Wang, Yu-Kun
    Han, Da
    Lin, Zhong-Qin
    IEEE TRANSACTIONS ON POWER DELIVERY, 2023, 38 (04) : 2924 - 2932
  • [3] MEASUREMENT OF SWITCHING TRANSIENTS IN 735-KV SUBSTATIONS AND ASSESSMENT OF THEIR SEVERITY FOR TRANSFORMER INSULATION
    MALEWSKI, R
    DOUVILLE, J
    LAVALLEE, L
    IEEE TRANSACTIONS ON POWER DELIVERY, 1988, 3 (04) : 1380 - 1390
  • [4] Study on the Transient Process of 500kV Substations Secondary Equipment
    Li, Hongbo
    Li, Pei
    Zhang, Yanyan
    Niu, Lin
    Gao, Nannan
    Si, Tailong
    Guo, Jiadong
    Xu, Min-min
    Li, Guofeng
    Guo, Liangfeng
    2017 2ND ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2017), 2017, 199
  • [5] Research on gap width of outdoor distribution equipment in 500kV substations
    Zhang, Yu-Fang
    2005, Power System Technology Press (29)
  • [6] Measurement and analysis of electromagnetic disturbances in ±500kV converter stations
    Zhang, Weidong
    Cui, Xiang
    Zhao, Jie
    Li, Xiaolin
    Wang, Qi
    Zhao, Zhibin
    Wang, Yuanyou
    EMC ZURICH-MUNICH 2007, SYMPOSIUM DIGEST, 2007, : 249 - +
  • [7] Transients in Control Cables during Switching at 220 kV Transformer Substations.
    Franke, G.
    Quaeck, L.
    1600, (19):
  • [8] Measurement and Analysis of Electromagnetic Disturbances in 500kV DC Converter Station
    Chen, Wei
    Jia, Lin
    Yu, Le
    Li, Meng
    2012 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2012,
  • [9] The switching transient electric field measurements in a 500kV substation
    Lu, BX
    Wang, ZZ
    Li, CR
    Ding, LJ
    Wang, W
    Zhang, WD
    2002 3RD INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, 2002, : 194 - 197
  • [10] MEASUREMENT OF SWITCHING TRANSIENTS IN A 115KV SUBSTATION
    WIGGINS, CM
    NICKEL, FS
    HANEY, AJ
    WRIGHT, SE
    IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (01) : 756 - 769