X-ray microbeam measurements with a high resolution scintillator fibre-optic dosimeter

被引:20
作者
Archer, James [1 ]
Li, Enbang [1 ]
Petasecca, Marco [1 ,2 ]
Dipuglia, Andrew [1 ]
Cameron, Matthew [1 ]
Stevenson, Andrew [3 ]
Hall, Chris [3 ]
Hausermann, Daniel [3 ]
Rosenfeld, Anatoly [1 ,2 ]
Lerch, Michael [1 ,2 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2522, Australia
[2] Univ Wollongong, Illawarra Hlth & Med Res Inst, Wollongong, NSW 2522, Australia
[3] Australian Synchrotron, Imaging & Med Beam Line, Melbourne, Vic 3168, Australia
来源
SCIENTIFIC REPORTS | 2017年 / 7卷
基金
澳大利亚国家健康与医学研究理事会;
关键词
RADIATION-THERAPY MRT; ENERGY BEAM DOSIMETRY; IRRADIATION; DETECTORS;
D O I
10.1038/s41598-017-12697-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Synchrotron microbeam radiation therapy is a novel external beam therapy under investigation, that uses highly brilliant synchrotron x-rays in microbeams 50 mu m width, with separation of 400 mu m, as implemented here. Due to the fine spatial fractionation dosimetry of these beams is a challenging and complicated problem. In this proof-of-concept work, we present a fibre optic dosimeter that uses plastic scintillator as the radiation conversion material. We claim an ideal one-dimensional resolution of 50 mu m. Using plastic scintillator and fibre optic makes this dosimeter water-equivalent, a very desirable dosimetric property. The dosimeter was tested at the Australian Synchrotron, on the Imaging and Medical Beam-Line. The individual microbeams were able to be resolved and the peak-to-valley dose ratio and the full width at half maximum of the microbeams was measured. These results are compared to a semiconductor strip detector of the same spatial resolution. A percent depth dose was measured and compared to data acquired by an ionisation chamber. The results presented demonstrate significant steps towards the development of an optical dosimeter with the potential to be applied in quality assurance of microbeam radiation therapy, which is vital if clinical trials are to be performed on human patients.
引用
收藏
页数:7
相关论文
共 22 条
[1]  
Archer J., 2014, THESIS
[2]   High-resolution fiber-optic dosimeters for microbeam radiation therapy [J].
Archer, James ;
Li, Enbang ;
Petasecca, Marco ;
Lerch, Michael ;
Rosenfeld, Anatoly ;
Carolan, Martin .
MEDICAL PHYSICS, 2017, 44 (05) :1965-1968
[3]   Micrometer-resolved film dosimetry using a microscope in microbeam radiation therapy [J].
Bartzsch, Stefan ;
Lott, Johanna ;
Welsch, Katrin ;
Braeuer-Krisch, Elke ;
Oelfke, Uwe .
MEDICAL PHYSICS, 2015, 42 (07) :4069-4079
[4]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .2. PROPERTIES AND MEASUREMENTS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1901-1913
[5]   WATER-EQUIVALENT PLASTIC SCINTILLATION DETECTORS FOR HIGH-ENERGY BEAM DOSIMETRY .1. PHYSICAL CHARACTERISTICS AND THEORETICAL CONSIDERATIONS [J].
BEDDAR, AS ;
MACKIE, TR ;
ATTIX, FH .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (10) :1883-1900
[6]   Fiber-optic detector for real time dosimetry of a micro-planar x-ray beam [J].
Belley, Matthew D. ;
Stanton, Ian N. ;
Hadsell, Mike ;
Ger, Rachel ;
Langloss, Brian W. ;
Lu, Jianping ;
Zhou, Otto ;
Chang, Sha X. ;
Therien, Michael J. ;
Yoshizumi, Terry T. .
MEDICAL PHYSICS, 2015, 42 (04) :1966-1972
[7]  
Birks J., 1964, THEORY PRACTICE SCIN
[8]  
Blattmann H, 2002, STRAHLENTHER ONKOL, V178, P118
[9]   Tunable synchrotron-like radiation from centimeter scale plasma channels [J].
Chen, Min ;
Luo, Ji ;
Li, Fei-Yu ;
Liu, Feng ;
Sheng, Zheng-Ming ;
Zhang, Jie .
LIGHT-SCIENCE & APPLICATIONS, 2016, 5 :e16015-e16015
[10]  
CURTIS HOWARD J., 1963, ADVANCES BIOL MED PHYS, V9, P207