A 3D electrochemical immunodevice based on a porous Pt-paper electrode and metal ion functionalized flower-like Au nanoparticles

被引:22
作者
Li, Li [1 ]
Kong, Qingkun [1 ]
Zhang, Yan [1 ]
Dong, Chunmeng [1 ]
Ge, Shenguang [2 ]
Yu, Jinghua [1 ]
机构
[1] Univ Jinan, Shandong Univ, Key Lab Chem Sensing & Anal, Jinan 250022, Peoples R China
[2] Univ Jinan, Shandong Prov Key Lab Preparat & Measurement Bldg, Jinan 250022, Peoples R China
基金
中国国家自然科学基金;
关键词
LAB-ON-PAPER; PHOTOCATALYTIC ACTIVITY; GOLD NANOPARTICLES; IMMUNOASSAY; NANOSTRUCTURES; CATALYSIS; GROWTH; PROBE; WAX;
D O I
10.1039/c4tb01946f
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
A 3D microfluidic paper-based electrochemical immunodevice (mu-PEID) for simultaneous sensitive detection of two tumor biomarkers was fabricated. A nanoporous Pt particle modified paper working electrode (NPPt-PWE) was used as the matrix and metal ions loaded on the L-cysteine capped flower-like Au nanoparticles (Au-Cys) were used as a signal amplification label. The NPPt-PWE was constructed through the growth of a NPPt layer on the back of the paper working electrode to improve electron conduction. Besides, the prepared flower-like Au-Cys could significantly enhance the amount of loaded metal ions and played an important role in connecting the signal antibodies. The metal ion labels could be detected directly through differential pulse voltammetry without metal pre-concentration, and the distinct voltammetric peaks had a close relationship with each sandwich-type immunoreaction. Therefore, a novel 3D mu-PEID for simultaneously detecting carcinoembryonic antigen (CEA) and alpha-fetoprotein (AFP) with wider linear ranges was developed. The linear range was from 0.004 to 200 ng mL(-1) and the limits of detection for AFP and CEA were 1.0 pg mL(-1) and 1.3 pg mL(-1) (S/N = 3), respectively. The good stability, reproducibility, and accuracy of the mu-PEID indicate that it has great potential application in clinical diagnostics.
引用
收藏
页码:2764 / 2769
页数:6
相关论文
共 40 条
[1]   Lab-on-Paper with Dual Electrochemical/Colorimetric Detection for Simultaneous Determination of Gold and Iron [J].
Apilux, Amara ;
Dungchai, Wijitar ;
Siangproh, Weena ;
Praphairaksit, Narong ;
Henry, Charles S. ;
Chailapakul, Orawon .
ANALYTICAL CHEMISTRY, 2010, 82 (05) :1727-1732
[2]   Understanding Wax Printing: A Simple Micropatterning Process for Paper-Based Microfluidics [J].
Carrilho, Emanuel ;
Martinez, Andres W. ;
Whitesides, George M. .
ANALYTICAL CHEMISTRY, 2009, 81 (16) :7091-7095
[3]   Facile hydrothermal synthesis and photocatalytic activity of bismuth tungstate hierarchical hollow spheres with an ultrahigh surface area [J].
Dai, Xiao-Jun ;
Luo, Yong-Song ;
Zhang, Wei-Dong ;
Fu, Shao-Yun .
DALTON TRANSACTIONS, 2010, 39 (14) :3426-3432
[4]   Gold nanoparticles: Assembly, supramolecular chemistry, quantum-size-related properties, and applications toward biology, catalysis, and nanotechnology [J].
Daniel, MC ;
Astruc, D .
CHEMICAL REVIEWS, 2004, 104 (01) :293-346
[5]   Electrogenerated Chemiluminescence Detection in Paper-Based Microfluidic Sensors [J].
Delaney, Jacqui L. ;
Hogan, Conor F. ;
Tian, Junfei ;
Shen, Wei .
ANALYTICAL CHEMISTRY, 2011, 83 (04) :1300-1306
[6]   Electrospun Co3O4 nanofibers for sensitive and selective glucose detection [J].
Ding, Yu ;
Wang, Ying ;
Su, Liang ;
Bellagamba, Michael ;
Zhang, Heng ;
Lei, Yu .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (02) :542-548
[7]   Ultrasensitive Multianalyte Electrochemical Immunoassay Based on Metal Ion Functionalized Titanium Phosphate Nanospheres [J].
Feng, Li-Na ;
Bian, Zhi-Ping ;
Peng, Juan ;
Jiang, Fang ;
Yang, Guo-Hai ;
Zhu, Ying-Di ;
Yang, Di ;
Jiang, Li-Ping ;
Zhu, Jun-Jie .
ANALYTICAL CHEMISTRY, 2012, 84 (18) :7810-7815
[8]   Three-dimensional paper-based electrochemiluminescence immunodevice for multiplexed measurement of biomarkers and point-of-care testing [J].
Ge, Lei ;
Yan, Jixian ;
Song, Xianrang ;
Yan, Mei ;
Ge, Shenguang ;
Yu, Jinghua .
BIOMATERIALS, 2012, 33 (04) :1024-1031
[9]   Chemical sensing and catalysis by one-dimensional metal-oxide nanostructures [J].
Kolmakov, A ;
Moskovits, M .
ANNUAL REVIEW OF MATERIALS RESEARCH, 2004, 34 :151-180
[10]   Growth of gold-manganese oxide nanostructures on a 3D origami device for glucose-oxidase label based electrochemical immunosensor [J].
Li, Long ;
Xu, Jinmeng ;
Zheng, Xiaoxiao ;
Ma, Chao ;
Song, Xianrang ;
Ge, Shenguang ;
Yu, Jinghua ;
Yan, Mei .
BIOSENSORS & BIOELECTRONICS, 2014, 61 :76-82