Comprehensive study and optimization of concentrated photovoltaic-thermoelectric considering all contact resistances

被引:94
作者
Shittu, Samson [1 ]
Li, Guiqiang [1 ,2 ]
Zhao, Xudong [1 ,2 ]
Ma, Xiaoli [1 ]
Akhlaghi, Yousef Golizadeh [1 ]
Fan, Yi [1 ]
机构
[1] Univ Hull, Res Ctr Sustainable Energy Technol, Kingston Upon Hull HU6 7RX, N Humberside, England
[2] North China Elect Power Univ, Dept Power Engn, Beijing, Peoples R China
基金
“创新英国”项目; 英国工程与自然科学研究理事会;
关键词
Photovoltaic-thermoelectric; Contact resistance; Thermal contact; Electrical contact; Finite element method; MICROCHANNEL HEAT-PIPE; PERFORMANCE ANALYSIS; TEMPERATURE DISTRIBUTION; NUMERICAL-ANALYSIS; COOLING SYSTEM; HYBRID SYSTEM; SOLAR-CELL; GENERATOR; DESIGN; GEOMETRY;
D O I
10.1016/j.enconman.2019.112422
中图分类号
O414.1 [热力学];
学科分类号
摘要
A consequence of the integration of photovoltaic module and thermoelectric generator is the presence of thermal contact, which affects the heat transfer in the hybrid system. Thermal and electrical contact are inevitable in a thermoelectric generator and their effects on the performance of the thermoelectric generator can be significant if not properly managed. Therefore, this study presents a comprehensive three-dimensional numerical investigation on the effect of contact resistances on the performance of concentrated photovoltaic-thermoelectric using COMSOL 5.4 Multiphysics software. Four contact resistances are studied including thermoelectric thermal contact resistance, thermoelectric electrical contact resistance, photovoltaic-thermoelectric interface thermal contact resistance and thermoelectric generator-heat sink interface thermal contact resistance. Twelve contact resistance cases are considered, and a comparison study is presented to investigate the most important contact resistance. In addition, a parametric optimization study is performed to investigate the optimum values for thermoelectric leg height, load resistance, concentration ratio and convective heat transfer coefficient. Results show that ignoring all contact resistances in the hybrid system causes an overestimation of overall power output and efficiency by 7.6% and 7.4% respectively using the base values considered in this study. In addition, the thermal contact resistance between the thermoelectric generator and heat sink, and that between the photovoltaic-thermoelectric interface are found to be the most important contact resistances, which should be reduced. Furthermore, results show that the optimum thermoelectric external load resistance in a hybrid system is lower than that of the thermoelectric generator only system. This study will provide valuable guidance on photovoltaic-thermoelectric accurate modelling.
引用
收藏
页数:17
相关论文
共 64 条
[1]   Statistical investigation of a dehumidification system performance using Gaussian process regression [J].
Akhlaghi, Yousef Golizadeh ;
Zhao, Xudong ;
Shittu, Samson ;
Badiei, Ali ;
Cattaneo, Marco E. G. V. ;
Ma, Xiaoli .
ENERGY AND BUILDINGS, 2019, 202
[2]   A statistical model for dew point air cooler based on the multiple polynomial regression approach [J].
Akhlaghi, Yousef Golizadeh ;
Ma, Xiaoli ;
Zhao, Xudong ;
Shittu, Samson ;
Li, Junming .
ENERGY, 2019, 181 :868-881
[3]   Finite elements for thermoelectric device analysis in ANSYS [J].
Antonova, EE ;
Looman, DC .
ICT: 2005 24TH INTERNATIONAL CONFERENCE ON THERMOELECTRICS, 2005, :200-203
[4]   An Analytical Model for the Influence of Contact Resistance on Thermoelectric Efficiency [J].
Bjork, Rasmus .
JOURNAL OF ELECTRONIC MATERIALS, 2016, 45 (03) :1301-1308
[5]   A comprehensive analysis of the performance of thermoelectric generators with constant and variable properties [J].
Chen, Wei-Hsin ;
Lin, Yi-Xian ;
Wang, Xiao-Dong ;
Lin, Yu-Li .
APPLIED ENERGY, 2019, 241 :11-24
[6]   Effective design, theoretical and experimental assessment of a solar thermoelectric cooling-heating system [J].
Daghigh, Roonak ;
Khaledian, Yavar .
SOLAR ENERGY, 2018, 162 :561-572
[7]   A numerical and experimental analysis of an integrated TEG-PCM power enhancement system for photovoltaic cells [J].
Darkwa, J. ;
Calautit, J. ;
Du, D. ;
Kokogianakis, G. .
APPLIED ENERGY, 2019, 248 :688-701
[8]   Influence of leg sizing and spacing on power generation and thermal stresses of thermoelectric devices [J].
Erturun, Ugur ;
Erermis, Kaan ;
Mossi, Karla .
APPLIED ENERGY, 2015, 159 :19-27
[9]   SIMPLIFIED METHOD FOR PREDICTING PHOTO-VOLTAIC ARRAY OUTPUT [J].
EVANS, DL .
SOLAR ENERGY, 1981, 27 (06) :555-560
[10]   Theory of fractional order in generalized thermoelectric MHD [J].
Ezzat, Magdy A. .