Fractures of the proximal third of the tibial shaft treated with intramedullary nails and blocking screws

被引:139
作者
Ricci, WM
O'Boyle, M
Borrelli, J
Bellabarba, C
Sanders, R
机构
[1] Washington Univ, Sch Med, Dept Orthopaed Surg, St Louis, MO 63110 USA
[2] Carolina Orthopaed Ctr, Greenville, SC USA
[3] Univ Washington, Dept Orthopaed, Seattle, WA 98195 USA
[4] Florida Orthopaed Inst, Tampa, FL USA
关键词
tibia fracture; proximal; alignment; blocking screws; intramedullary nails;
D O I
10.1097/00005131-200105000-00005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: To describe the technique and results of using blocking screws and intramedullary nails to treat patients with fractures of the proximal third of the tibial shaft. Design: Prospective. Setting: Level I trauma centers. Patients: Twelve consecutive patients treated with intramedullary nailing and blocking screws for fractures of the proximal third of the tibial shaft. Intervention: Patients were treated with intramedullary nails and blocking screws. Main Outcome Measure: The alignment of fractures was determined using standard anteroposterior and lateral radiographs after surgery and at each follow-up examination. One patient was lost to follow-up. All other patients: were followed at regular intervals until union or establishment of a nonunion. Changes in alignment and complications were noted. Results: Postoperatively, all patients had less than 5 degrees of angular deformity in the planes in which blocking screws were used to control alignment. One patient had postoperative malalignment (6 degrees of valgus), but a lateral blocking screw to control valgus deformity was not used in this patient. One patient was lost to follow-up. Eleven patients were followed up to union (n = 10) or establishment of a nonunion (n = I). Ten of eleven patients maintained their postoperative fracture: alignment at their Last follow-up examination (average follow-up of thirty-three weeks). One patient progressed fi om 6 degrees of valgus immediately after surgery to 10 degrees of valgus at union. This patient did not have: a blocking screw to control valgus angulation. Conclusions: Blocking screws are effective to help obtain and maintain alignment of fractures of the proximal third of the tibial shaft treated with intramedullary nails.
引用
收藏
页码:264 / 270
页数:7
相关论文
共 21 条
[1]  
Ahlers J, 1992, Unfallchirurgie, V18, P31, DOI 10.1007/BF02588237
[2]   LOCKED INTRAMEDULLARY NAILING FOR DISPLACED TIBIAL SHAFT FRACTURES [J].
ALHO, A ;
EKELAND, A ;
STROMSOE, K ;
FOLLERAS, G ;
THORESEN, BO .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (05) :805-809
[3]   TREATMENT OF TIBIAL FRACTURES BY REAMING AND INTRAMEDULLARY NAILING [J].
BONE, LB ;
JOHNSON, KD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (06) :877-887
[4]   A technique for intramedullary nailing of proximal third tibia fractures [J].
Buehler, KC ;
Green, J ;
Woll, TS ;
Duwelius, PJ .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (03) :218-223
[5]   CLOSED INTRAMEDULLARY TIBIAL NAILING - ITS USE IN CLOSED AND TYPE-I OPEN FRACTURES [J].
COURTBROWN, CM ;
CHRISTIE, J ;
MCQUEEN, MM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (04) :605-611
[6]   Reamed or unreamed nailing for closed tibial fractures - A prospective study in Tscherne C1 fractures [J].
CourtBrown, CM ;
Will, E ;
Christie, J ;
McQueen, MM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1996, 78B (04) :580-583
[7]  
FREEDMAN EL, 1995, CLIN ORTHOP RELAT R, V315, P25
[8]   PREVENTION OF INFECTION IN TREATMENT OF 1000 AND 25 OPEN FRACTURES OF LONG BONES - RETROSPECTIVE AND PROSPECTIVE ANALYSES [J].
GUSTILO, RB ;
ANDERSON, JT .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (04) :453-458
[9]   INFLUENCES OF SOME DESIGN PARAMETERS ON THE BIOMECHANICS OF THE UNREAMED TIBIAL INTRAMEDULLARY NAIL [J].
HENLEY, MB ;
MEIER, M ;
TENCER, AF .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1993, 7 (04) :311-319
[10]  