A Single-Ended Fault Location Method for Grid-Connected Converter System Based on Control and Protection Coordination

被引:14
作者
Chang, Peng [1 ]
Song, Guobing [1 ]
Hou, Junjie [1 ]
Xu, Ruidong [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, Xian 710049, Peoples R China
关键词
Fault location; Mathematical models; Control systems; Resistance; Impedance; Voltage control; Inductance; grid-connected converter system; two-stage control strategy; control and protection coordination; CONTROL STRATEGY; VOLTAGE;
D O I
10.1109/TPWRD.2021.3122976
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Traditional single-ended fault location method is influenced by the fault resistance, and the remote in feed, which reflects as the two equations built by fault phase have four unknowns. And in the grid-connected converter system, the weak feedback characteristic further reduces the performance of the method. To solve it, a single-ended fault location method based on control and protection coordination is proposed in this paper. First, using the high controlled-ability of the converter, the control strategy for fault ride-through (FRT) operation is divided into two stages by switching control modes. Then, according to the electrical quantities under two stages, four uncorrelated equations can be established, and the equations still have four unknown parameters. The fault distance can be calculated by solving them. The simulation results show that the proposed method has high accuracy and is immune to fault resistance and fault location, it solves the problem of insufficient equations in principle.
引用
收藏
页码:3071 / 3081
页数:11
相关论文
共 24 条
[1]  
[Anonymous], 2018, T369952018 GB
[2]   Impedance-Based Fault Location in Transmission Networks: Theory and Application [J].
Das, Swagata ;
Santoso, Surya ;
Gaikwad, Anish ;
Patel, Mahendra .
IEEE ACCESS, 2014, 2 :537-557
[3]   A Wide-Area Scheme for Power System Fault Location Incorporating Bad Data Detection [J].
Dobakhshari, Ahmad Salehi ;
Ranjbar, Ali Mohammad .
IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (02) :800-808
[4]   Dynamic Analysis of MMC-Based MTDC Grids: Use of MMC Energy to Improve Voltage Behavior [J].
Freytes, Julian ;
Akkari, Samy ;
Rault, Pierre ;
Belhaouane, Mohamed Moez ;
Gruson, Francois ;
Colas, Frederic ;
Guillaud, Xavier .
IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (01) :137-148
[5]   Distance Protection of Lines Emanating From Full-Scale Converter-Interfaced Renewable Energy Power Plants-Part I: Problem Statement [J].
Hooshyar, Ali ;
Azzouz, Maher A. ;
El-Saadany, Ehab F. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (04) :1770-1780
[6]   A New Single Ended Fault Location Method for Transmission Line Based on Positive Sequence Superimposed Network During Auto-Reclosing [J].
Ji, Liang ;
Tao, Xiaojie ;
Fu, Yang ;
Fu, Yong ;
Mi, Yang ;
Li, Zhenkun .
IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (03) :1019-1029
[7]   Modular Multilevel Converter (MMC) Modeling Considering Submodule Voltage Sensor Noise [J].
Ji, Shiqi ;
Huang, Xingxuan ;
Palmer, James ;
Wang, Fred ;
Tolbert, Leon M. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (02) :1215-1219
[8]   A Review on Grid-Connected Converter Control for Short-Circuit Power Provision Under Grid Unbalanced Faults [J].
Jia, Jundi ;
Yang, Guangya ;
Nielsen, Arne Hejde .
IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (02) :649-661
[9]   Second Harmonic Injection-Based Recovery Control of PV DC Boosting Integration System [J].
Jia, Ke ;
Chen, Jinfeng ;
Zhao, Guankun ;
Yang, Bin ;
Bi, Tianshu .
IEEE TRANSACTIONS ON SMART GRID, 2021, 12 (02) :1022-1032
[10]   Control of Active and Reactive Power Ripple to Mitigate Unbalanced Grid Voltages [J].
Kabiri, Roozbeh ;
Holmes, Donald Grahame ;
McGrath, Brendan Peter .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2016, 52 (02) :1660-1668