Short-Term Cardiovascular Response to Short-Radius Centrifugation With and Without Ergometer Exercise

被引:21
作者
Diaz-Artiles, Ana [1 ]
Heldt, Thomas [2 ,3 ]
Young, Laurence R. [4 ]
机构
[1] Texas A&M Univ, Dept Aerosp Engn, College Stn, TX 77843 USA
[2] MIT, Inst Med Engn & Sci, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[3] MIT, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
[4] MIT, Dept Aeronaut & Astronaut, Cambridge, MA 02139 USA
关键词
artificial gravity; orthostatic intolerance; human experiments; spaceflight deconditioning; spaceflight countermeasure; INTERNATIONAL-SPACE-STATION; LONG-DURATION SPACEFLIGHT; HUMAN SKELETAL-MUSCLE; ARTIFICIAL GRAVITY; ARTERIAL-PRESSURE; CARDIAC-OUTPUT; BED REST; ORTHOSTATIC TOLERANCE; SIMULATED MICROGRAVITY; COMPRESSION GARMENTS;
D O I
10.3389/fphys.2018.01492
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Artificial gravity (AG) has often been proposed as an integrated multi-system countermeasure to physiological deconditioning associated with extended exposure to reduced gravity levels, particularly if combined with exercise. Twelve subjects underwent short-radius centrifugation along with bicycle ergometry to quantify the short-term cardiovascular response to AG and exercise across three AG levels (0 G or no rotation, 1 G, and 1.4 G; referenced to the subject's feet and measured in the centripetal direction) and three exercise intensities (25, 50, and 100 W). Continuous cardiovascular measurements were collected during the centrifugation sessions using a non-invasive monitoring system. The cardiovascular responses were more prominent at higher levels of AG and exercise intensity. In particular, cardiac output, stroke volume, pulse pressure, and heart rate significantly increased with both AG level (in most of exercise group combinations, showing averaged increments across exercise conditions of 1.4 L/min/g, 7.6 mL/g, 5.22 mmHg/g, and 2.0 bpm/g, respectively), and workload intensity (averaged increments across AG conditions of 0.09 L/min/W, 0.17 mL/W, 0.22 mmHg/W, and 0.74 bpm/W respectively). These results suggest that the addition of AG to exercise can provide a greater cardiovascular benefit than exercise alone. Hierarchical regression models were fitted to the experimental data to determine dose-response curves of all cardiovascular variables as a function of AG-level and exercise intensity during short-radius centrifugation. These results can inform future studies, decisions, and trade-offs toward potential implementation of AG as a space countermeasure.
引用
收藏
页数:16
相关论文
共 91 条
[1]  
Abdi H., 2010, Encycl. Res. Des., V3, P1, DOI DOI 10.4135/9781412961288.N168
[2]   Pulse Contour Methods to Estimate Cardiovascular Indices in Micro- And Hypergravity [J].
Arai, Tatsuya ;
Limper, Ulrich ;
Gauger, Peter ;
Beck, Luis .
AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 2013, 84 (11) :1178-1185
[3]   Effects of artificial gravity on the cardiovascular system: Computational approach [J].
Artiles, Ana Diaz ;
Heldt, Thomas ;
Young, Laurence R. .
ACTA ASTRONAUTICA, 2016, 126 :395-410
[4]   Autonomic cardiovascular and respiratory control during prolonged spaceflights aboard the International Space Station [J].
Baevsky, Roman M. ;
Baranov, Victor M. ;
Funtova, Irina I. ;
Diedrich, Andre ;
Pashenko, Andrey V. ;
Chernikova, Anja G. ;
Drescher, Juergen ;
Jordan, Jens ;
Tank, Jens .
JOURNAL OF APPLIED PHYSIOLOGY, 2007, 103 (01) :156-161
[5]   Radiation as a Risk Factor for Cardiovascular Disease [J].
Baker, John E. ;
Moulder, John E. ;
Hopewell, John W. .
ANTIOXIDANTS & REDOX SIGNALING, 2011, 15 (07) :1945-1956
[6]   NONINVASIVE CARDIAC OUTPUT MONITORING DURING EXERCISE TESTING: NEXFIN PULSE CONTOUR ANALYSIS COMPARED TO AN INERT GAS REBREATHING METHOD AND RESPIRED GAS ANALYSIS [J].
Bartels, Sebastiaan A. ;
Stok, Wim J. ;
Bezemer, Rick ;
Boksem, Remco J. ;
van Goudoever, Jeroen ;
Cherpanath, Thomas G. V. ;
van Lieshout, Johannes J. ;
Westerhof, Berend E. ;
Karemaker, John M. ;
Ince, Can .
JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2011, 25 (05) :315-321
[7]   Pulse contour cardiac output derived from non-invasive arterial pressure in cardiovascular disease [J].
Bogert, L. W. J. ;
Wesseling, K. H. ;
Schraa, O. ;
Van Lieshout, E. J. ;
de Mol, B. A. J. M. ;
van Goudoever, J. ;
Westerhof, B. E. ;
van Lieshout, J. J. .
ANAESTHESIA, 2010, 65 (11) :1119-1125
[8]   Non-invasive pulsatile arterial pressure and stroke volume changes from the human finger [J].
Bogert, LWJ ;
van Lieshout, JJ .
EXPERIMENTAL PHYSIOLOGY, 2005, 90 (04) :437-446
[9]   Determinants of oxygen consumption during exercise on cycle ergometer: The effects of gravity acceleration [J].
Bonjour, Julien ;
Capelli, Carlo ;
Antonutto, Guglielmo ;
Calza, Stefano ;
Tam, Enrico ;
Linnarsson, Dag ;
Ferretti, Guido .
RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2010, 171 (02) :128-134
[10]   A comparison of the Nexfin® and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery [J].
Broch, O. ;
Renner, J. ;
Gruenewald, M. ;
Meybohm, P. ;
Schoettler, J. ;
Caliebe, A. ;
Steinfath, M. ;
Malbrain, M. ;
Bein, B. .
ANAESTHESIA, 2012, 67 (04) :377-383