Computer-assisted navigation increases precision of component placement in total knee arthroplasty

被引:242
作者
Haaker, RG [1 ]
Stockheim, M [1 ]
Kamp, M [1 ]
Proff, G [1 ]
Breitenfelder, J [1 ]
Ottersbach, A [1 ]
机构
[1] St Vincents Hosp, Dept Orthopaed Surg, D-33034 Brakel, Germany
关键词
D O I
10.1097/01.blo.0000150564.31880.c4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
In our clinical study, 200 total knee arthroplasties were evaluated to compare the use of the OrthoPilot system with conventional mechanical instrumentation. Long-term outcome of total knee replacement depends mainly on the accuracy of implant positioning and restoration of the mechanical leg axis. Our experience was that navigation could achieve a greater degree of accuracy concerning the aforementioned aspects. Among 513 primary-inserted total knee replacements, 100 navigated knees were compared with 100 conventionally implanted knees after matching the two groups of patients by gender, body mass index, age, preoperative deformities, radiographic findings, and operating time. Three weeks after surgery, the radiographic results were significantly better in the computer-assisted group compared with the results in the conventional group when we assessed component positioning in four axes. Only the sagittal tibial component angle was not significantly different. Total knee arthroplasty using the OrthoPilot system led to increased precision of tibial and femoral component positioning in comparison with hand-guided replacement surgery. An additional 10 minutes of operating time was acceptable. Navigation-specific complications were not seen, and the number of outliers decreased. Because computer navigation in orthopaedics is a new technology, data regarding long-term outcomes are not available.
引用
收藏
页码:152 / 159
页数:8
相关论文
共 50 条
[21]  
Kienapfel H, 2003, ORTHOPADE, V32, P312, DOI 10.1007/s00132-002-0441-7
[22]   SURVIVAL OF KNEE ARTHROPLASTIES - A NATIONWIDE MULTICENTER INVESTIGATION OF 8000 CASES [J].
KNUTSON, K ;
LINDSTRAND, A ;
LIDGREN, L .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (05) :795-803
[23]   A MATHEMATICAL-ANALYSIS OF THE EFFECT OF FLEXION AND ROTATION ON APPARENT VARUS VALGUS ALIGNMENT AT THE KNEE [J].
KRACKOW, KA ;
PEPE, CL ;
GALLOWAY, EJ .
ORTHOPEDICS, 1990, 13 (08) :861-868
[24]  
Krackow KA, 1999, ORTHOPEDICS, V22, P698
[25]  
LASKIN RS, 1984, ORTHOPEDICS, V7, P62, DOI 10.3928/0147-7447-19840101-09
[26]  
Leitner F, 1997, CVRMED MRCAS, P630
[27]  
Löer I, 2003, ORTHOPADE, V32, P296, DOI 10.1007/s00132-002-0440-8
[28]   The effect of surgeon experience on component positioning in 673 Press Fit Condylar posterior cruciate-sacrificing total knee arthroplasties [J].
Mahaluxmivala, J ;
Bankes, MJK ;
Nicolai, P ;
Aldam, CH ;
Allen, PW .
JOURNAL OF ARTHROPLASTY, 2001, 16 (05) :635-640
[29]  
MIEHLKE R, 2003, NAVIGATION ROBOTICS, P242
[30]   Navigation in knee arthroplasty - Preliminary clinical experience and prospective comparative study in comparison with conventional technique [J].
Mielke, RK ;
Clemens, U ;
Lens, JH ;
Kershally, S .
ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2001, 139 (02) :109-116