DC Comparison of a Programmable Josephson Voltage Standard and a Josephson Arbitrary Waveform Synthesizer

被引:0
作者
Rufenacht, Alain [1 ]
Flowers-Jacobs, Nathan E. [1 ]
Fox, Anna E. [1 ]
Waltman, Steven B. [1 ]
Schwall, Robert E. [1 ]
Burroughs, Charles J. [1 ]
Dresselhaus, Paul D. [1 ]
Benz, Samuel P. [1 ]
机构
[1] NIST, Boulder, CO 80305 USA
来源
2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018) | 2018年
关键词
Digital-analog conversion; Josephson arrays; standards; superconducting integrated circuits; voltage measurement;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present the first dc comparison of a programmable Josephson voltage standards and a pulse-driven Josephson arbitrary waveform synthesizer (JAWS) at 3 V. Both circuits are mounted side-by-side on the cold stage of a cryocooler. The relative agreement achieved was better than 1 part in 10(8). This measurement allowed us to identify systematic errors of the JAWS system. An undesired current injection from the JAWS isolation amplifier into the measurement circuit was responsible for an error voltage of a few nanovolts.
引用
收藏
页数:2
相关论文
共 5 条
[1]   Direct comparison of a 1 V Josephson arbitrary waveform synthesizer and an ac quantum voltmeter [J].
Behr, Ralf ;
Kieler, Oliver ;
Lee, Jinni ;
Bauer, Stephan ;
Palafox, Luis ;
Kohlmann, Johannes .
METROLOGIA, 2015, 52 (04) :528-537
[2]   NIST 10 V Programmable Josephson Voltage Standard System [J].
Burroughs, Charles J., Jr. ;
Dresselhaus, Paul D. ;
Ruefenacht, Alain ;
Olaya, David ;
Elsbury, Michael M. ;
Tang, Yi-Hua ;
Benz, Samuel P. .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2011, 60 (07) :2482-2488
[3]  
Flowers-Jacobs N. E., 2016, IEEE T APPL SUPERCON, V26
[4]   Cryocooled 10 V Programmable Josephson Voltage Standard [J].
Ruefenacht, Alain ;
Howe, Logan A. ;
Fox, Anna E. ;
Schwall, Robert E. ;
Dresselhaus, Paul D. ;
Burroughs, Charles J., Jr. ;
Benz, Samuel P. .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (06) :1477-1482
[5]   Direct comparison of two NIST PJVS systems at 10 V [J].
Solve, S. ;
Ruefenacht, A. ;
Burroughs, C. J. ;
Benz, S. P. .
METROLOGIA, 2013, 50 (05) :441-451