A Novel Grid-Connected Converter with Active Power Filtering Function
被引:9
作者:
He, Chao
论文数: 0引用数: 0
h-index: 0
机构:
Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Zhejiang, Peoples R ChinaZhejiang Univ, Coll Elect Engn, Hangzhou 310027, Zhejiang, Peoples R China
He, Chao
[1
]
Xie, Xin
论文数: 0引用数: 0
h-index: 0
机构:
New United Grp, Changzhou, Jiangsu, Peoples R ChinaZhejiang Univ, Coll Elect Engn, Hangzhou 310027, Zhejiang, Peoples R China
Xie, Xin
[2
]
Yan, Hui
论文数: 0引用数: 0
h-index: 0
机构:
Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Zhejiang, Peoples R ChinaZhejiang Univ, Coll Elect Engn, Hangzhou 310027, Zhejiang, Peoples R China
Yan, Hui
[1
]
Xie, Chuan
论文数: 0引用数: 0
h-index: 0
机构:
Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Zhejiang, Peoples R ChinaZhejiang Univ, Coll Elect Engn, Hangzhou 310027, Zhejiang, Peoples R China
Xie, Chuan
[1
]
Chen, Guozhu
论文数: 0引用数: 0
h-index: 0
机构:
Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Zhejiang, Peoples R ChinaZhejiang Univ, Coll Elect Engn, Hangzhou 310027, Zhejiang, Peoples R China
Chen, Guozhu
[1
]
机构:
[1] Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Zhejiang, Peoples R China
[2] New United Grp, Changzhou, Jiangsu, Peoples R China
来源:
PROCEEDINGS OF INTERNATIONAL CONFERENCE ON SMART GRID AND CLEAN ENERGY TECHNOLOGIES (ICSGCE 2011)
|
2011年
/
12卷
关键词:
Grid-connected converter;
active power filter;
proportional integral control;
feedforward control;
D O I:
10.1016/j.egypro.2011.10.047
中图分类号:
TE [石油、天然气工业];
TK [能源与动力工程];
学科分类号:
0807 ;
0820 ;
摘要:
A Novel Grid-Connected Converter with ActivePower Filtering Function was proposed. Considering the specific situation, main circuit and controller were designed. The proposed system can exchange active power with grid and/or compensate harmonic current and reactive power of grid at the same time or respectively. LCL type filter was adopted to attain a good filtering effect. Proportional Integral (PI) control, repetitive control as well as feed forward control which can gain better dynamic performance composed the control system. To track the time-varying active current value, the influence of time lag caused by repetitive control during the fast switching period was considered. DC link voltage controller was designed for its special applications. Simulation results verify the high steady state precision and fast dynamic response of the system. (C) 2011 Published by Elsevier Ltd. Selection and/or peer-review under responsibility of University of Electronic Science and Technology of China (UESTC).
机构:
Inst Potosino Invest Cient & Tecnol, Div Appl Math, San Luis Potosi 78216, MexicoInst Potosino Invest Cient & Tecnol, Div Appl Math, San Luis Potosi 78216, Mexico
Escobar, G.
;
Martinez, P. R.
论文数: 0引用数: 0
h-index: 0
机构:Inst Potosino Invest Cient & Tecnol, Div Appl Math, San Luis Potosi 78216, Mexico
Martinez, P. R.
;
Leyva-Ramos, J.
论文数: 0引用数: 0
h-index: 0
机构:Inst Potosino Invest Cient & Tecnol, Div Appl Math, San Luis Potosi 78216, Mexico
机构:
Inst Potosino Invest Cient & Tecnol, Div Appl Math, San Luis Potosi 78216, MexicoInst Potosino Invest Cient & Tecnol, Div Appl Math, San Luis Potosi 78216, Mexico
Escobar, G.
;
Martinez, P. R.
论文数: 0引用数: 0
h-index: 0
机构:Inst Potosino Invest Cient & Tecnol, Div Appl Math, San Luis Potosi 78216, Mexico
Martinez, P. R.
;
Leyva-Ramos, J.
论文数: 0引用数: 0
h-index: 0
机构:Inst Potosino Invest Cient & Tecnol, Div Appl Math, San Luis Potosi 78216, Mexico