EFFECTS OF DIFFERENT THERAPEUTIC ULTRASOUND INTENSITIES ON FRACTURE HEALING IN RATS

被引:32
作者
Fung, Chak-Hei [1 ]
Cheung, Wing-Hoi [1 ,3 ]
Pounder, Neill M. [2 ]
de Ana, F. Javier [2 ]
Harrison, Andrew [2 ]
Leung, Kwok-Sui [1 ,3 ]
机构
[1] Chinese Univ Hong Kong, Dept Orthopaed & Traumatol, Shatin, Hong Kong, Peoples R China
[2] Smith & Nephew Inc, Orthopaed Trauma & Clin Therapies, Durham, NC USA
[3] Chinese Acad Sci, Shenzhen Inst Adv Technol, Inst Biomed & Hlth Engn, Shenzhen, Peoples R China
关键词
LIPUS; Ultrasound; Intensity; Fracture healing; PULSED ULTRASOUND; BONE-FORMATION; DISTRACTION OSTEOGENESIS; GENE-EXPRESSION; NITRIC-OXIDE; CELLS; PROLIFERATION; OSTEOBLASTS; CALLUS; REPAIR;
D O I
10.1016/j.ultrasmedbio.2012.01.022
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Low-intensity pulsed ultrasound (LIPUS) with I-SATA = 30 mW/cm(2) has been proven in facilitating fracture healing, which the spatial average intensity over the on period (I-SATP) equals 150 mW/cm(2). As active ultrasound wave is only delivered during the on period, we postulate 150 mW/cm(2) is responsible for the beneficial effect of LIPUS. In this study, we compare the biologic effects of 30 mW/cm(2) and 150 mW/cm(2). We propose I-SATA = 150 mW/cm(2) could further enhance fracture healing process. Closed femoral fractured Sprague-Dawley rats were randomized into control, LIPUS-30 (30 mW/cm(2)) and LIPUS-150 (150 mW/cm(2)) groups. Weekly radiographs and endpoint microCT, histomorphometry, and biomechanical tests were performed. The results show that LIPUS-30 had significantly higher low-density bone volume fraction and woven bone percentage than that of control and LIPUS-150 in microCT and histologic measurements, respectively. Mechanically, failure torque of LIPUS-30 was significantly higher than control and LIPUS-150 at week 6. In conclusion, LIPUS at I-SATA = 150 mW/cm(2) did not further enhance fracture healing. (E-mail: louis@ort.cuhk.edu.hk) (C) 2012 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:745 / 752
页数:8
相关论文
共 35 条
[1]   Osteogenic differentiation of rat bone marrow stromal cells by various intensities of low-intensity pulsed ultrasound [J].
Angle, S. R. ;
Sena, K. ;
Sumner, D. R. ;
Virdi, A. S. .
ULTRASONICS, 2011, 51 (03) :281-288
[2]  
[Anonymous], 2019, Diagnostic Ultrasound, Physics and Equipment
[3]   ULTRASONIC ENERGY AND SURGICALLY PRODUCED DEFECTS IN BONE [J].
ARDAN, NI ;
JANES, JM ;
HERRICK, JF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1957, 39 (02) :394-402
[4]   Low-intensity pulsed ultrasound accelerates rat femoral fracture healing by acting on the various cellular reactions in the fracture callus [J].
Azuma, Y ;
Ito, M ;
Harada, Y ;
Takagi, H ;
Ohta, T ;
Jingushi, S .
JOURNAL OF BONE AND MINERAL RESEARCH, 2001, 16 (04) :671-680
[5]   The production of nitric oxide and prostaglandin E2 by primary bone cells is shear stress dependent [J].
Bakker, AD ;
Soejima, K ;
Klein-Nulend, J ;
Burger, EH .
JOURNAL OF BIOMECHANICS, 2001, 34 (05) :671-677
[6]   EXPRESSION OF PROLIFERATION-ASSOCIATED ANTIGENS (PCNA, P120, P145) DURING THE REENTRY OF G(0) CELLS INTO THE CELL-CYCLE [J].
BOLTON, WE ;
FREEMAN, JW ;
MIKULKA, WR ;
HEALY, CG ;
SCHMITTLING, RJ ;
KENYON, NS .
CYTOMETRY, 1994, 17 (01) :66-74
[7]   Guidelines for Assessment of Bone Microstructure in Rodents Using Micro-Computed Tomography [J].
Bouxsein, Mary L. ;
Boyd, Stephen K. ;
Christiansen, Blaine A. ;
Guldberg, Robert E. ;
Jepsen, Karl J. ;
Mueller, Ralph .
JOURNAL OF BONE AND MINERAL RESEARCH, 2010, 25 (07) :1468-1486
[8]  
Busse JW, 2002, CAN MED ASSOC J, V166, P437
[9]   Dose-dependent effect of low-intensity pulsed ultrasound on callus formation during rapid distraction osteogenesis [J].
Chan, Chun Wai ;
Qin, Ling ;
Lee, Kwong Man ;
Cheung, Wing Hoi ;
Cheng, Jack Chun Yiu ;
Leung, Kwok Sui .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (11) :2072-2079
[10]   The enhancement of bone regeneration by ultrasound [J].
Claes, Lutz ;
Willie, Bettina .
PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 2007, 93 (1-3) :384-398