Trimethylsilyldiazomethane derivatization coupled with solid-phase extraction for the determination of alendronate in human plasma by LC-MS/MS

被引:29
作者
Chen, Meixia [1 ]
Liu, Ke [1 ]
Zhong, Dafang [1 ]
Chen, Xiaoyan [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Mat Med, Shanghai 201203, Peoples R China
关键词
Alendronate; Derivatization; LC-MS/MS; Trimethylsilyldiazomethane; Pharmacokinetics; PERFORMANCE LIQUID-CHROMATOGRAPHY; ION CHROMATOGRAPHY; HUMAN URINE; MASS SPECTROMETRY; BISPHOSPHONATES; FLUORESCENCE; SODIUM; WOMEN;
D O I
10.1007/s00216-011-5467-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Alendronate is an important representative of bisphosphonates, strongly polar compounds that lack chromophores. With rare exceptions, derivatization of the analytes is necessary for bioanalysis. In this study, a rapid liquid chromatography-tandem mass spectrometry method employing pre-column derivatization was developed and validated for the determination of alendronate concentrations in human plasma. The procedure was based on derivatization with trimethylsilyldiazomethane during solid-phase extraction on a weak anion-exchange solid-phase cartridge, which integrated sample purification and derivatization into one step. The alendronate derivative was eluted with methanol. Chromatographic separation was performed on a Capcell PAK-C18 column. The total run time was 6.5 min. The calibration curve was linear in the range 1.00-1,000 ng/mL using d6-alendronate as the internal standard. The lower limit of quantification was 1.00 ng/mL. The intra- and inter-assay precision (in RSD) calculated from quality control samples was less than 15%, and the accuracy was between 98.1% and 100.2%. The validated method was successfully applied to characterize the pharmacokinetic profiles of alendronate following the intravenous infusion of 5 or 10 mg alendronate sodium to healthy volunteers.
引用
收藏
页码:791 / 798
页数:8
相关论文
共 25 条
[1]   Spectroscopic and HPLC methods for the determination of alendronate in tablets and urine [J].
Al Deeb, SK ;
Hamdan, II ;
Al Najjar, SM .
TALANTA, 2004, 64 (03) :695-702
[2]   Application of a semi-automated 96-well format solid-phase extraction, column-switching, fluorescence detection protocol for the determination of alendronate in human urine samples obtained from a bioequivalence study [J].
Apostolou, Constantinos ;
Dotsikas, Yannis ;
Kousoulos, Constantinos ;
Tsatsou, Georgia ;
Colocouri, Filomila ;
Soumelas, Georgios-Stefanos ;
Loukas, Yannis L. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (03) :1151-1155
[3]   Effects of Teriparatide, Alendronate, or Both in Women with Postmenopausal Osteoporosis [J].
Finkelstein, Joel S. ;
Wyland, Jason J. ;
Lee, Hang ;
Neer, Robert M. .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2010, 95 (04) :1838-1845
[4]   Bisphosphonates in osteoporosis [J].
Fleisch, H .
EUROPEAN SPINE JOURNAL, 2003, 12 (Suppl 2) :S142-S146
[5]   Determination of alendronate sodium by ion chromatography with refractive index detection [J].
Han, YHR ;
Qin, XZ .
JOURNAL OF CHROMATOGRAPHY A, 1996, 719 (02) :345-352
[6]   Prevention of bone loss with alendronate in postmenopausal women under 60 years of age [J].
Hosking, D ;
Chilvers, CED ;
Christiansen, C ;
Ravn, P ;
Wasnich, R ;
Ross, P ;
McClung, M ;
Balske, A ;
Thompson, D ;
Daley, M ;
Yates, AJ .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (08) :485-492
[7]  
Jeong Y, 2011, B KOREAN CHEM SOC, V32, P1
[8]   HPLC method validation and pharmacokinetic study of alendronate sodium in human urine with fluorescence detection [J].
Kang, Hyun-Suk ;
Hwang, Sung-Joo ;
Park, Jeong-Sook ;
Kim, Chong-Kook .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (11) :1589-1600
[9]   IMPROVED DETERMINATION OF THE BISPHOSPHONATE ALENDRONATE IN HUMAN PLASMA AND URINE BY AUTOMATED PRECOLUMN DERIVATIZATION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE AND ELECTROCHEMICAL DETECTION [J].
KLINE, WF ;
MATUSZEWSKI, BK .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 583 (02) :183-193
[10]  
Lu Z, 2008, Patent Application Publication US, Patent No. [2008/0169242 A1, 20080169242]