Morphologic characteristics of periprosthetic tissues from hip prostheses with ceramic-ceramic couples - A comparative histologic investigation of 18 revision and 30 autopsy cases

被引:26
作者
Bos, I
Willmann, G
机构
[1] Univ Klinikum Lubeck, Inst Pathol, DE-23538 Lubeck, Germany
[2] CeramTec AG, Plochingen, Germany
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 2001年 / 72卷 / 04期
关键词
D O I
10.1080/000164701753541970
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Pseudocapsules and interface membranes from 18 revision cases having hip prostheses with ceramic-ceramic couples and 30 autopsy specimens (6 with ceramic-ceramic couples, 7 with ceramic-polyethylene combinations and 17 with metal-polyethylene combinations) were histomorphologically analyzed, including a semiquantitative grading of the wear particles and histologic changes. Unlike the revision cases, which usually showed ceramic wear particles in the adjacent tissues, only half of the autopsy cases revealed ceramic wear. As compared to the ceramic-polyethylene and metal-polyethylene couples, the alumina on alumina combinations showed a thinner synovial layer with reduced villous transformation and smaller infiltrates of macrophages and necroses, which can be explained by the absence of polyethylene wear. Metal-polyethylene couplings produced more than twice as many polyethylene wear particles with correspondingly more marked foreign body reaction than the ceramic-polyethylene couplings.
引用
收藏
页码:335 / 342
页数:8
相关论文
共 35 条
[1]  
[Anonymous], CLIN ORTHOP
[2]   LONG-TERM RESULTS OF UNCEMENTED ALUMINA ACETABULAR IMPLANTS [J].
BOEHLER, M ;
KNAHR, K ;
PLENK, H ;
WALTER, A ;
SALZER, M ;
SCHREIBER, V .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (01) :53-59
[3]   OSTEOLYSIS AFTER CERAMIC-ON-CERAMIC HIP-ARTHROPLASTY - A CASE-REPORT [J].
BORSSEN, B ;
KARRHOLM, J ;
SNORRASON, F .
ACTA ORTHOPAEDICA SCANDINAVICA, 1991, 62 (01) :73-75
[4]   COMPARATIVE INVESTIGATIONS OF REGIONAL LYMPH-NODES AND PSEUDOCAPSULES AFTER IMPLANTATION OF JOINT ENDOPROSTHESES [J].
BOS, I ;
JOHANNISSON, R ;
LOHRS, U ;
LINDNER, B ;
SEYDEL, U .
PATHOLOGY RESEARCH AND PRACTICE, 1990, 186 (06) :707-716
[5]  
BOS I, 1991, PATHOLOGE, V12, P82
[6]  
BOS I, 2000, Z ORTHOP, V128, P73
[7]  
Bosch C P, 1987, Aktuelle Probl Chir Orthop, V31, P87
[8]   THE PROOF OF DIMETHYLPARATOLUIDINE IN BONE-CEMENT EVEN AFTER LONG-TIME IMPLANTATION [J].
BOSCH, P ;
HARMS, H ;
LINTNER, F .
ARCHIVES OF TOXICOLOGY, 1982, 51 (02) :157-166
[9]  
BOUTIN P, 1981, REV CHIR ORTHOP, V67, P279
[10]  
Clarke I C, 1988, Ann N Y Acad Sci, V523, P292, DOI 10.1111/j.1749-6632.1988.tb38524.x