Analytical protocol for determination of endosulfan beta, propham, chlorpyrifos, and acibenzolar-s-methyl in lake water and wastewater samples by gas chromatography-mass spectrometry after dispersive liquid-liquid microextraction

被引:7
作者
Bodur, Suleyman [1 ]
Ozlu, Cansu [1 ]
Tisli, Busra [1 ]
Firat, Merve [1 ]
Chormey, Dotse Selali [1 ]
Bakirdere, Sezgin [1 ]
机构
[1] Yildiz Tech Univ, Fac Art & Sci, Dept Chem, TR-34210 Istanbul, Turkey
关键词
Dispersive liquid-liquid microextraction; Gas chromatography-mass spectrometry; Box-Behnken experimental design; Pesticides; BOX-BEHNKEN DESIGN; PESTICIDE CHLORPYRIFOS; EXTRACTION; ENVIRONMENT; QUECHERS;
D O I
10.1007/s10661-020-8214-5
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study describes the development of a sensitive and accurate dispersive liquid-liquid microextraction strategy for the preconcentration and determination of selected pesticides in wastewater and lake water samples by gas chromatography-mass spectrometry. Determination of these pesticides at high accuracy and precision is important because they can be still be found in environmental samples. The type of extraction solvent and type of disperser solvent were optimized using the univariate approach. Furthermore, a Box-Behnken experimental design was used to set up a working model made up of 18 combinations of three variables, tested at three levels. The parameters fitted into the design model were volume of extraction solvent, disperser solvent volume, and mixing period. Analysis of variance was used to evaluate the experimental data to determine the significance of extraction variables and their interactions, before selecting optimum extraction conditions. The method was then applied to aqueous standard solutions between 2.0 and 500 mu g L-1, and the limit of detection (LOD) and quantification (LOQ) values obtained for the analytes were between 0.37-2.8 and 1.2-9.4 mu g L-1, respectively. The percent recoveries were calculated in the range of 92-114 and 96-110% for wastewater and lake water, respectively. These results validated the accuracy and applicability of the method to the selected matrices.
引用
收藏
页数:9
相关论文
共 34 条
[1]  
[Anonymous], 2014, ADV GAS CHROMATOGRAP
[2]   Green Analytical Chemistry [J].
Armenta, S. ;
Garrigues, S. ;
de la Guardia, M. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (06) :497-511
[3]   Quantification of DEET and neonicotinoid pesticide biomarkers in human urine by online solid-phase extraction high-performance liquid chromatography-tandem mass spectrometry [J].
Baker, Samuel E. ;
Serafim, Amanda Bishop ;
Morales-Agudelo, Pilar ;
Vidal, Meghan ;
Calafat, Antonia M. ;
Ospina, Maria .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (03) :669-678
[4]   Genotoxicity of pesticides: potential risk for consumers [J].
Bolognesi, C ;
Morasso, G .
TRENDS IN FOOD SCIENCE & TECHNOLOGY, 2000, 11 (4-5) :182-187
[5]   The benefits of pesticides to mankind and the environment [J].
Cooper, Jerry ;
Dobson, Hans .
CROP PROTECTION, 2007, 26 (09) :1337-1348
[6]   MASS SPECTROMETRY-BASED METABOLOMICS OF YEAST [J].
Crutchfield, Christopher A. ;
Lu, Wenyun ;
Melamud, Eugene ;
Rabinowitz, Joshua D. .
METHODS IN ENZYMOLOGY, VOL 470: GUIDE TO YEAST GENETICS:: FUNCTIONAL GENOMICS, PROTEOMICS, AND OTHER SYSTEMS ANALYSIS, 2ND EDITION, 2010, 470 :393-426
[7]   Determination of butyltin compounds in fish and mussel samples at trace levels by vortex assisted dispersive liquid-liquid microextraction-gas chromatography mass spectrometry [J].
Erarpat, Sezin ;
Bodur, Suleyman ;
Oz, Ersoy ;
Bakirdere, Sezgin .
JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2019, 82
[8]   Box-Behnken design: An alternative for the optimization of analytical methods [J].
Ferreira, S. L. C. ;
Bruns, R. E. ;
Ferreira, H. S. ;
Matos, G. D. ;
David, J. M. ;
Brandao, G. C. ;
da Silva, E. G. P. ;
Portugal, L. A. ;
dos Reis, P. S. ;
Souza, A. S. ;
dos Santos, W. N. L. .
ANALYTICA CHIMICA ACTA, 2007, 597 (02) :179-186
[9]   Biodegradation of α and β endosulfan by Aspergillus sydoni [J].
Goswami, Supriya ;
Vig, Komal ;
Singh, Dileep K. .
CHEMOSPHERE, 2009, 75 (07) :883-888
[10]   Comparison of hollow fiber liquid phase microextraction and dispersive liquid-liquid microextraction for the determination of organosulfur pesticides in environmental and beverage samples by gas chromatography with flame photometric detection [J].
Jun Xiong ;
Bin Hu .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1193 (1-2) :7-18