Effect of manual eyelid manipulation on intraocular pressure measurement by rebound tonometry

被引:8
|
作者
Baek, Sung Uk [1 ,2 ]
Ha, Ahnul [1 ,2 ]
Kim, Young Kook [1 ,2 ]
Jeoung, Jin Wook [1 ,2 ]
Park, Ki Ho [1 ,2 ]
机构
[1] Seoul Natl Univ, Dept Ophthalmol, Coll Med, Seoul, South Korea
[2] Seoul Natl Univ Hosp, Dept Ophthalmol, Seoul, South Korea
关键词
glaucoma; intraocular pressure; eye lids; GOLDMANN APPLANATION TONOMETER;
D O I
10.1136/bjophthalmol-2017-311587
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background/aims To investigate the effect of eyelid manipulation on the measurement of intraocular pressure (IOP) using two different tonometries (rebound tonometry (RT) vs Goldmann applanation tonometry (GAT)). Methods 103 patients with primary open-angle glaucoma were prospectively enrolled. For all of the patients, IOP measurements were performed in three different ways: (1) RT with lid manipulation (LM), (2) RT without LM and (3) GAT. The order of the three measurements was randomly selected. Additionally, the palpebral fissure height (PFH; elliptical space between upper and lower eyelids) was measured. Results The mean value of IOP measured by GAT was 13.972.80mm Hg, which was not significantly different from that by RT without LM (13.75 +/- 2.44mm Hg; P=0.096), but which was significantly lower than that by RT with LM (15.21 +/- 2.91mm Hg; P<0.001). On a Bland-Altman plot, RT with LM was overestimated relative to GAT (mean: -1.5) and RT without LM (mean: -1.2). Among the high IOPs (>20mm Hg), interestingly, those measured by RT without LM were significantly lower than those measured by GAT (P<0.001). In the subgroup analysis of PFH, the smaller the PFH, the more exaggerated the IOP difference between GAT (P=0.014) and RT with LM (P<0.001). Conclusion RT-measured IOP was significantly exaggerated when manipulation was applied to the eyelid. This overall trend was more pronounced when PFH was small. GAT-measured IOP, meanwhile, showed a good correlation with IOP measured using RT without LM.
引用
收藏
页码:1515 / 1519
页数:5
相关论文
共 50 条
  • [41] Monitoring intraocular pressure changes after intravitreal Ranibizumab injection using rebound tonometry
    Fuest, Matthias
    Kotliar, Konstantin
    Walter, Peter
    Plange, Niklas
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2014, 34 (04) : 438 - 444
  • [42] Comparison of Intraocular Pressure Measurements Obtained by Rebound, Noncontact, and Goldmann Applanation Tonometry in Children
    Feng, Chi Shian
    Jin, Ki Won
    Yi, Kayoung
    Choi, Dong Gyu
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 160 (05) : 937 - 943
  • [43] Rebound tonometry: new opportunities and limitations of non-invasive determination of intraocular pressure
    Cervino, A.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (12) : 1444 - 1446
  • [44] Noninvasive measurement of rodent intraocular pressure with a rebound tonometer
    Wang, WH
    Millar, JC
    Pang, IH
    Wax, MB
    Clark, AF
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (12) : 4617 - 4621
  • [45] Intraocular Pressure Measurements Using Rebound Tonometry in Eight Different Species of Companion Birds
    Karimi, Vahid
    Asadi, Faezeh
    Rajaei, Seyed Mehdi
    Golabdar, Salar
    JOURNAL OF AVIAN MEDICINE AND SURGERY, 2020, 34 (04) : 338 - 342
  • [46] Intraocular Pressure during Trabeculectomy. Comparison of Intuitive Compression Tonometry versus IC-200 Rebound Tonometry
    Tornero-Jimenez, Andrea
    Paczka, Jose A.
    Ponce Horta, Ana Maria
    Escobedo Espinoza, Jonathan
    Orozco Garcia, Andrea
    Fernanda Vazquez, Isis
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2022, 63 (07)
  • [47] Does the order of intraocular pressure measurement affect tonometry results?
    Pe'er, Oren
    Chiu, Eni
    Arad, Dikla
    Lelescu, Cristina
    Ross, Maya
    Ofri, Ron
    VETERINARY OPHTHALMOLOGY, 2021, 24 : 146 - 153
  • [48] Measurement of intraocular pressure after LASIK by dynamic contour tonometry
    Liu Lei
    Lei Cheng
    Li Xinyu
    Dong Jieyu
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2006, 26 (3): : 372 - 373
  • [49] Comparison of Intraocular Pressure Measurement Variability with Goldmann and iCare Tonometry
    McMillan, Brian
    DeVience, Eva
    Gross, Ronald L.
    Ramadan, Jad
    Goundappa, Balasubramani K.
    Realini, Tony
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [50] Measurement of Intraocular Pressure after LASIK by Dynamic Contour Tonometry
    刘磊
    雷澄
    李新宇
    董洁玉
    华中科技大学学报(医学英德文版), 2006, (03) : 372 - 373