Effect of manual eyelid manipulation on intraocular pressure measurement by rebound tonometry

被引:8
作者
Baek, Sung Uk [1 ,2 ]
Ha, Ahnul [1 ,2 ]
Kim, Young Kook [1 ,2 ]
Jeoung, Jin Wook [1 ,2 ]
Park, Ki Ho [1 ,2 ]
机构
[1] Seoul Natl Univ, Dept Ophthalmol, Coll Med, Seoul, South Korea
[2] Seoul Natl Univ Hosp, Dept Ophthalmol, Seoul, South Korea
关键词
glaucoma; intraocular pressure; eye lids; GOLDMANN APPLANATION TONOMETER;
D O I
10.1136/bjophthalmol-2017-311587
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background/aims To investigate the effect of eyelid manipulation on the measurement of intraocular pressure (IOP) using two different tonometries (rebound tonometry (RT) vs Goldmann applanation tonometry (GAT)). Methods 103 patients with primary open-angle glaucoma were prospectively enrolled. For all of the patients, IOP measurements were performed in three different ways: (1) RT with lid manipulation (LM), (2) RT without LM and (3) GAT. The order of the three measurements was randomly selected. Additionally, the palpebral fissure height (PFH; elliptical space between upper and lower eyelids) was measured. Results The mean value of IOP measured by GAT was 13.972.80mm Hg, which was not significantly different from that by RT without LM (13.75 +/- 2.44mm Hg; P=0.096), but which was significantly lower than that by RT with LM (15.21 +/- 2.91mm Hg; P<0.001). On a Bland-Altman plot, RT with LM was overestimated relative to GAT (mean: -1.5) and RT without LM (mean: -1.2). Among the high IOPs (>20mm Hg), interestingly, those measured by RT without LM were significantly lower than those measured by GAT (P<0.001). In the subgroup analysis of PFH, the smaller the PFH, the more exaggerated the IOP difference between GAT (P=0.014) and RT with LM (P<0.001). Conclusion RT-measured IOP was significantly exaggerated when manipulation was applied to the eyelid. This overall trend was more pronounced when PFH was small. GAT-measured IOP, meanwhile, showed a good correlation with IOP measured using RT without LM.
引用
收藏
页码:1515 / 1519
页数:5
相关论文
共 50 条
  • [31] Intraocular Pressure Measurements Using Rebound Tonometry in Eight Different Species of Companion Birds
    Karimi, Vahid
    Asadi, Faezeh
    Rajaei, Seyed Mehdi
    Golabdar, Salar
    JOURNAL OF AVIAN MEDICINE AND SURGERY, 2020, 34 (04) : 338 - 342
  • [32] Does Rebound Tonometry Probe Misalignment Modify Intraocular Pressure Measurements in Human Eyes?
    Beasley, Ian G.
    Laughton, Deborah S.
    Coldrick, Benjamin J.
    Drew, Thomas E.
    Sallah, Marium
    Davies, Leon N.
    JOURNAL OF OPHTHALMOLOGY, 2013, 2013
  • [33] INTRAOCULAR PRESSURE IN CLINICALLY NORMAL BROOK TROUT (SALVELINUS FONTINALIS) BY MEANS OF REBOUND TONOMETRY
    Keeney, Caitlin Hepps
    Vorbach, Bryan
    Clayton, Leigh
    Seeley, Kathryn
    JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2019, 50 (01) : 107 - 110
  • [34] Measurement of intraocular pressure after LASIK by dynamic contour tonometry
    Liu Lei
    Lei Cheng
    Li Xinyu
    Dong Jieyu
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2006, 26 (3): : 372 - 373
  • [35] Measurement of Intraocular Pressure after LASIK by Dynamic Contour Tonometry
    刘磊
    雷澄
    李新宇
    董洁玉
    华中科技大学学报(医学英德文版), 2006, (03) : 372 - 373
  • [36] Differential impact of prostaglandin analogues on agreement of intraocular pressure measurements obtained by Goldmann applanation, rebound, and noncontact tonometry
    Jung, Younhea
    Suh, Hyun
    Moon, Jung Il
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [37] Measurement of Intraocular Pressure Using Rebound Tonometry in Anesthetized Free-ranging South American Sea Lions (Otaria byronia)
    Sheldon, Julie D.
    Adkesson, Michael J.
    Allender, Matthew C.
    Jankowski, Gwen
    Cardenas-Alayza, Susana
    JOURNAL OF WILDLIFE DISEASES, 2019, 55 (04) : 885 - 888
  • [38] An overview of home tonometry and telemetry for intraocular pressure monitoring in humans
    Yung, Edward
    Trubnik, Valerie
    Katz, L. Jay
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (08) : 1179 - 1188
  • [39] The influence of refractive errors on IOP measurement by rebound tonometry (ICare) and Goldmann applanation tonometry
    Teresio Avitabile
    Antonio Longo
    Daniela Rocca
    Roberta Amato
    Caterina Gagliano
    Marine Castaing
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 585 - 591
  • [40] Intraocular pressure estimates using rebound tonometry in juvenile northern bobwhite quails (Colinus virginianus)
    Spitznagel, Katya
    Sadar, Miranda
    Pucket, Jonathan
    Kanda, Ian
    Brandao, Joao
    VETERINARY OPHTHALMOLOGY, 2022, 25 (06) : 506 - 509