Effect of manual eyelid manipulation on intraocular pressure measurement by rebound tonometry

被引:8
|
作者
Baek, Sung Uk [1 ,2 ]
Ha, Ahnul [1 ,2 ]
Kim, Young Kook [1 ,2 ]
Jeoung, Jin Wook [1 ,2 ]
Park, Ki Ho [1 ,2 ]
机构
[1] Seoul Natl Univ, Dept Ophthalmol, Coll Med, Seoul, South Korea
[2] Seoul Natl Univ Hosp, Dept Ophthalmol, Seoul, South Korea
关键词
glaucoma; intraocular pressure; eye lids; GOLDMANN APPLANATION TONOMETER;
D O I
10.1136/bjophthalmol-2017-311587
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background/aims To investigate the effect of eyelid manipulation on the measurement of intraocular pressure (IOP) using two different tonometries (rebound tonometry (RT) vs Goldmann applanation tonometry (GAT)). Methods 103 patients with primary open-angle glaucoma were prospectively enrolled. For all of the patients, IOP measurements were performed in three different ways: (1) RT with lid manipulation (LM), (2) RT without LM and (3) GAT. The order of the three measurements was randomly selected. Additionally, the palpebral fissure height (PFH; elliptical space between upper and lower eyelids) was measured. Results The mean value of IOP measured by GAT was 13.972.80mm Hg, which was not significantly different from that by RT without LM (13.75 +/- 2.44mm Hg; P=0.096), but which was significantly lower than that by RT with LM (15.21 +/- 2.91mm Hg; P<0.001). On a Bland-Altman plot, RT with LM was overestimated relative to GAT (mean: -1.5) and RT without LM (mean: -1.2). Among the high IOPs (>20mm Hg), interestingly, those measured by RT without LM were significantly lower than those measured by GAT (P<0.001). In the subgroup analysis of PFH, the smaller the PFH, the more exaggerated the IOP difference between GAT (P=0.014) and RT with LM (P<0.001). Conclusion RT-measured IOP was significantly exaggerated when manipulation was applied to the eyelid. This overall trend was more pronounced when PFH was small. GAT-measured IOP, meanwhile, showed a good correlation with IOP measured using RT without LM.
引用
收藏
页码:1515 / 1519
页数:5
相关论文
共 50 条
  • [21] COMPARISON OF INTRAOCULAR PRESSURE MEASUREMENT USING REBOUND AND APPLANATION TONOMETRY IN LOGGERHEAD (CARETTA CARETTA) SEA TURTLES
    Lamagna, Barbara
    Affuso, Andrea
    Micieli, Fabiana
    Mennonna, Giuseppina
    Meomartino, Leonardo
    Della Valle, Giovanni
    Ciampa, Mariapia
    Treglia, Gianluca
    Hochscheid, Sandra
    JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2021, 52 (02) : 604 - 609
  • [22] Dynamic contour tonometry for intraocular pressure measurement
    Kamppeter, BA
    Jonas, JB
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (02) : 318 - 320
  • [23] Rebound tonometry versus Goldmann tonometry in school children: feasibility and agreement of intraocular pressure measurements
    Barranco Esporcatte, Bruno Leonardo
    Santos Lopes, Flÿvio Siqueira
    Netto, Camila Fonseca
    Reboucas-Santos, Vespasiano
    Dias, Diego Torres
    Marujo, Fabio Iglesias
    Rolim-de-Moura, Christiane
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2015, 78 (06) : 359 - 362
  • [24] Clinical differences in rebound tonometry and Goldmann applanation tonometry measurements of intraocular pressure in adult patients
    Chiu, Zelia
    Collins, Camille
    van der Straaten, David
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 50 (08): : 923 - 924
  • [25] Agreement of rebound and applanation tonometry intraocular pressure measurements during atmospheric pressure change
    Vercellin, Alice Verticchio
    Harris, Alon
    Siesky, Brent
    Zukerman, Ryan
    Tanga, Lucia
    Carnevale, Carmela
    Scarinci, Fabio
    Oddone, Francesco
    PLOS ONE, 2021, 16 (10):
  • [26] Reference Intervals for Intraocular Pressure Measured by Rebound Tonometry in Ten Raptor Species and Factors Affecting the Intraocular Pressure
    Reuter, Anne
    Mueller, Kerstin
    Arndt, Gisela
    Eule, Johanna Corinna
    JOURNAL OF AVIAN MEDICINE AND SURGERY, 2011, 25 (03) : 165 - 172
  • [27] ASSESSMENT OF INTRAOCULAR PRESSURE BY APPLANATION AND REBOUND TONOMETRY IN GUINEA PIGS OF DIFFERENT AGES
    Cairo, Marti
    Teresa Pena, Maria
    Rios, Jose
    Melero, Adria
    Martorell, Jaume
    Leiva, Marta
    JOURNAL OF EXOTIC PET MEDICINE, 2018, 27 (01) : 25 - 31
  • [28] Technical Note:: A comparison of central and peripheral intraocular pressure using rebound tonometry
    Queiros, A.
    Gonzalez-Meijome, J. M.
    Fernandes, P.
    Jorge, J.
    Montes-Mico, R.
    Almeida, J. B.
    Parafita, M. A.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2007, 27 (05) : 506 - 511
  • [29] Assessment of intraocular pressure in chinchillas of different age groups using rebound tonometry
    Yokoay Claros Chacaltana, Flor Diana
    Tadeu Pigatto, Joao Antonio
    Denardin, Ione Terezinha
    CIENCIA RURAL, 2016, 46 (08): : 1466 - 1471
  • [30] Intraocular pressure in American Bullfrogs (Rana catesbeiana) measured with rebound and applanation tonometry
    Cannizzo, Sarah A.
    Lewbart, Gregory A.
    Westermeyer, Hans D.
    VETERINARY OPHTHALMOLOGY, 2017, 20 (06) : 526 - 532