Effect of manual eyelid manipulation on intraocular pressure measurement by rebound tonometry

被引:8
作者
Baek, Sung Uk [1 ,2 ]
Ha, Ahnul [1 ,2 ]
Kim, Young Kook [1 ,2 ]
Jeoung, Jin Wook [1 ,2 ]
Park, Ki Ho [1 ,2 ]
机构
[1] Seoul Natl Univ, Dept Ophthalmol, Coll Med, Seoul, South Korea
[2] Seoul Natl Univ Hosp, Dept Ophthalmol, Seoul, South Korea
关键词
glaucoma; intraocular pressure; eye lids; GOLDMANN APPLANATION TONOMETER;
D O I
10.1136/bjophthalmol-2017-311587
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background/aims To investigate the effect of eyelid manipulation on the measurement of intraocular pressure (IOP) using two different tonometries (rebound tonometry (RT) vs Goldmann applanation tonometry (GAT)). Methods 103 patients with primary open-angle glaucoma were prospectively enrolled. For all of the patients, IOP measurements were performed in three different ways: (1) RT with lid manipulation (LM), (2) RT without LM and (3) GAT. The order of the three measurements was randomly selected. Additionally, the palpebral fissure height (PFH; elliptical space between upper and lower eyelids) was measured. Results The mean value of IOP measured by GAT was 13.972.80mm Hg, which was not significantly different from that by RT without LM (13.75 +/- 2.44mm Hg; P=0.096), but which was significantly lower than that by RT with LM (15.21 +/- 2.91mm Hg; P<0.001). On a Bland-Altman plot, RT with LM was overestimated relative to GAT (mean: -1.5) and RT without LM (mean: -1.2). Among the high IOPs (>20mm Hg), interestingly, those measured by RT without LM were significantly lower than those measured by GAT (P<0.001). In the subgroup analysis of PFH, the smaller the PFH, the more exaggerated the IOP difference between GAT (P=0.014) and RT with LM (P<0.001). Conclusion RT-measured IOP was significantly exaggerated when manipulation was applied to the eyelid. This overall trend was more pronounced when PFH was small. GAT-measured IOP, meanwhile, showed a good correlation with IOP measured using RT without LM.
引用
收藏
页码:1515 / 1519
页数:5
相关论文
共 50 条
  • [21] Technical Note:: A comparison of central and peripheral intraocular pressure using rebound tonometry
    Queiros, A.
    Gonzalez-Meijome, J. M.
    Fernandes, P.
    Jorge, J.
    Montes-Mico, R.
    Almeida, J. B.
    Parafita, M. A.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2007, 27 (05) : 506 - 511
  • [22] Assessment of intraocular pressure in chinchillas of different age groups using rebound tonometry
    Yokoay Claros Chacaltana, Flor Diana
    Tadeu Pigatto, Joao Antonio
    Denardin, Ione Terezinha
    CIENCIA RURAL, 2016, 46 (08): : 1466 - 1471
  • [23] Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group
    Min Chen
    Lina Zhang
    Jia Xu
    Xinyi Chen
    Yuxiang Gu
    Yuping Ren
    Kaijun Wang
    BMC Ophthalmology, 19
  • [24] Comparability of three intraocular pressure measurement: iCare pro rebound, non-contact and Goldmann applanation tonometry in different IOP group
    Chen, Min
    Zhang, Lina
    Xu, Jia
    Chen, Xinyi
    Gu, Yuxiang
    Ren, Yuping
    Wang, Kaijun
    BMC OPHTHALMOLOGY, 2019, 19 (01)
  • [25] INTRAOCULAR PRESSURE IN CAPTIVE AMERICAN FLAMINGOS (PHOENICOPTERUS RUBER) AS MEASURED BY REBOUND TONOMETRY
    Molter, Christine M.
    Hollingsworth, Steven R.
    Kass, Philip H.
    Chinnadurai, Sathya K.
    Wack, Raymund F.
    JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2014, 45 (03) : 664 - 667
  • [26] Intraocular pressure in American Bullfrogs (Rana catesbeiana) measured with rebound and applanation tonometry
    Cannizzo, Sarah A.
    Lewbart, Gregory A.
    Westermeyer, Hans D.
    VETERINARY OPHTHALMOLOGY, 2017, 20 (06) : 526 - 532
  • [27] ASSESSMENT OF INTRAOCULAR PRESSURE BY APPLANATION AND REBOUND TONOMETRY IN GUINEA PIGS OF DIFFERENT AGES
    Cairo, Marti
    Teresa Pena, Maria
    Rios, Jose
    Melero, Adria
    Martorell, Jaume
    Leiva, Marta
    JOURNAL OF EXOTIC PET MEDICINE, 2018, 27 (01) : 25 - 31
  • [28] Intraocular pressure measurement with Corvis ST in comparison with applanation tonometry and Tomey non-contact tonometry
    Luebke, Jan
    Bryniok, L.
    Neuburger, M.
    Jordan, J. F.
    Boehringer, D.
    Reinhard, T.
    Wecker, T.
    Anton, A.
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (11) : 2517 - 2521
  • [29] Intraocular pressure measurement with Corvis ST in comparison with applanation tonometry and Tomey non-contact tonometry
    Jan Luebke
    L. Bryniok
    M. Neuburger
    J. F. Jordan
    D. Boehringer
    T. Reinhard
    T. Wecker
    A. Anton
    International Ophthalmology, 2019, 39 : 2517 - 2521
  • [30] Effect of Repeated Applanation Tonometry on the Accuracy of Intraocular Pressure Measurements
    Gaton, Dan D.
    Ehrenberg, Miriam
    Lusky, Moshe
    Wussuki-Lior, Orly
    Dotan, Gad
    Weinberger, Dov
    Snir, Moshe
    CURRENT EYE RESEARCH, 2010, 35 (06) : 475 - 479