Effect of manual eyelid manipulation on intraocular pressure measurement by rebound tonometry

被引:8
|
作者
Baek, Sung Uk [1 ,2 ]
Ha, Ahnul [1 ,2 ]
Kim, Young Kook [1 ,2 ]
Jeoung, Jin Wook [1 ,2 ]
Park, Ki Ho [1 ,2 ]
机构
[1] Seoul Natl Univ, Dept Ophthalmol, Coll Med, Seoul, South Korea
[2] Seoul Natl Univ Hosp, Dept Ophthalmol, Seoul, South Korea
关键词
glaucoma; intraocular pressure; eye lids; GOLDMANN APPLANATION TONOMETER;
D O I
10.1136/bjophthalmol-2017-311587
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background/aims To investigate the effect of eyelid manipulation on the measurement of intraocular pressure (IOP) using two different tonometries (rebound tonometry (RT) vs Goldmann applanation tonometry (GAT)). Methods 103 patients with primary open-angle glaucoma were prospectively enrolled. For all of the patients, IOP measurements were performed in three different ways: (1) RT with lid manipulation (LM), (2) RT without LM and (3) GAT. The order of the three measurements was randomly selected. Additionally, the palpebral fissure height (PFH; elliptical space between upper and lower eyelids) was measured. Results The mean value of IOP measured by GAT was 13.972.80mm Hg, which was not significantly different from that by RT without LM (13.75 +/- 2.44mm Hg; P=0.096), but which was significantly lower than that by RT with LM (15.21 +/- 2.91mm Hg; P<0.001). On a Bland-Altman plot, RT with LM was overestimated relative to GAT (mean: -1.5) and RT without LM (mean: -1.2). Among the high IOPs (>20mm Hg), interestingly, those measured by RT without LM were significantly lower than those measured by GAT (P<0.001). In the subgroup analysis of PFH, the smaller the PFH, the more exaggerated the IOP difference between GAT (P=0.014) and RT with LM (P<0.001). Conclusion RT-measured IOP was significantly exaggerated when manipulation was applied to the eyelid. This overall trend was more pronounced when PFH was small. GAT-measured IOP, meanwhile, showed a good correlation with IOP measured using RT without LM.
引用
收藏
页码:1515 / 1519
页数:5
相关论文
共 50 条
  • [1] Effect of eyelid manipulation and manual jugular compression on intraocular pressure measurement in dogs
    Klein, Heidi E.
    Krohne, Sheryl G.
    Moore, George E.
    Mohamed, Ahmed S.
    Stiles, Jean
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2011, 238 (10): : 1292 - 1295
  • [2] Validation of rebound tonometry for intraocular pressure measurement in the rabbit
    Zhang, Hong
    Yang, Dong
    Ross, Craig M.
    Wigg, Jonathan P.
    Pandav, Surinder
    Crowston, Jonathan G.
    EXPERIMENTAL EYE RESEARCH, 2014, 121 : 86 - 93
  • [3] Effect of body position, eyelid manipulation, and manual jugular compression on intraocular pressure in clinically normal cats
    Rajaei, Seyed Mehdi
    Asadi, Faezeh
    Rajabian, Mohammad Reza
    Ostadhassan, Hesam
    Crasta, Manuela
    VETERINARY OPHTHALMOLOGY, 2018, 21 (02) : 140 - 143
  • [4] Effect of manual upper eyelid elevation on intraocular pressure measurement by noncontact tonometer
    Gun, Raziye Donmez
    Simsek, Saban
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (09) : 2915 - 2923
  • [5] Effect of manual upper eyelid elevation on intraocular pressure measurement by noncontact tonometer
    Raziye Dönmez Gün
    Şaban Şimşek
    International Ophthalmology, 2022, 42 : 2915 - 2923
  • [6] Assessing the Reliability of Intraocular Pressure Measurements Using Rebound Tonometry
    Realini, Tony
    McMillan, Brian
    Gross, Ronald L.
    Devience, Eva
    Balasubramani, Goundappa K.
    JOURNAL OF GLAUCOMA, 2021, 30 (08) : 629 - 633
  • [7] Intraocular Pressure Measurement by Rebound Tonometry (TonoVet) in Normal Pigeons (Columba livia)
    Lim, Jaegook
    Kang, Seonmi
    Park, Sangwan
    Park, Eunjin
    Nam, Taekjin
    Jeong, Seowoo
    Seo, Kangmoon
    JOURNAL OF AVIAN MEDICINE AND SURGERY, 2019, 33 (01) : 46 - 52
  • [8] Monitoring intraocular pressure changes after intravitreal Ranibizumab injection using rebound tonometry
    Fuest, Matthias
    Kotliar, Konstantin
    Walter, Peter
    Plange, Niklas
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2014, 34 (04) : 438 - 444
  • [9] Rebound tonometry versus Goldmann tonometry in school children: feasibility and agreement of intraocular pressure measurements
    Barranco Esporcatte, Bruno Leonardo
    Santos Lopes, Flÿvio Siqueira
    Netto, Camila Fonseca
    Reboucas-Santos, Vespasiano
    Dias, Diego Torres
    Marujo, Fabio Iglesias
    Rolim-de-Moura, Christiane
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2015, 78 (06) : 359 - 362
  • [10] Acoustic Tonometry Feasibility Study of a New Principle of Intraocular Pressure Measurement
    von Freyberg, Axel
    Sorg, Michael
    Fuhrmann, Martina
    Kreiner, Christine F.
    Pfannkuche, Jens
    Klink, Thomas
    Hensler, Dina
    Grehn, Franz
    Goch, Gert
    JOURNAL OF GLAUCOMA, 2009, 18 (04) : 316 - 320